Summary of the content on the page No. 1
MADE IN
User’s Guide
CAUTION! – This product
is not intended for medical
use or use on humans
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
OS136 SERIES
Miniature Low-Cost
Non-Contact Infrared
Temperature Sensor/Transmitter
Summary of the content on the page No. 2
® OMEGAnet Online Service Internet e-mail omega.com info@omega.com Servicing North America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: ® U.S.A. and Canada
Summary of the content on the page No. 3
OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter Table of Contents Section Page Caution and Safety Information .................................................................. iii Safety Warnings and IEC Symbols .............................................................. iii Section 1 Introduction .................................................................................... 1 Section 2 Installation ...................................................
Summary of the content on the page No. 4
OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter List of Figures Figure Description Page 2-1 General Wiring Diagram ................................................................ 2 3-1 Optical Field of View ...................................................................... 3 3-2 Mounting Bracket, OS100-MB ....................................................... 4 3-3 Air Purge Collar, OS100-AP ...
Summary of the content on the page No. 5
OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter CAUTION & SAFETY INFORMATION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired. The Installation category is one (1). There is no user replaceable fuse in this product. The output terminals of this product are for use with equipment (Digital meters, chart recorders, etc.) which have no accessible live parts. Such equipment should comply wi
Summary of the content on the page No. 6
Introduction 1 SECTION 1 - INTRODUCTION The model OS136 series is a very low-cost, super-compact infrared transmitter. It measures temperature via non-contact, and provides an analog output proportional to the measured temperature. The OS136 series is offered in two temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF). The analog output is offered as 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, 10 mV/Degree C or F, or K type thermocouple. The unit has a fixed Emissivity of 0.95
Summary of the content on the page No. 7
Installation 2 The following describes the ordering information: OS136 – * – ** , where - * means: -1 : -18 to 204ºC (0 to 400ºF) Temperature range -2 : 149 to 538ºC (300 to 1000ºF) Temperature range - ** means: -MA : 4 to 20 mA current output -V1 : 0 to 5 Vdc output -V2 : 0 to 10 Vdc output -K : K type thermocouple output -MVC : 10 mV/ºC output -MVF : 10 mV/ºF output The following table lists the optional accessories: Accessories Model No. Description OS100-MB Mounting Bracket OS136-WC Water/
Summary of the content on the page No. 8
Operation 3 SECTION 3 – OPERATION 3.1 – Measuring Temperature Before starting to measure temperature, make sure the following check list is met: The Power and output connections are made (Fig 2-1) The target is larger than the optical field of view of the transmitter (Fig 3-1) Use the Laser Sighting accessory (Optional), to align the transmitter to the center of the target area. The Emissivity is fixed at 0.95. No adjustment is necessary. If the target Emissivity is less than 0.95, you c
Summary of the content on the page No. 9
3 Operation 3.3 - Atmospheric Quality Environments with smoke , dust, and fume dirty up the optical lens, and cause erroneous temperature readings. To keep the surface of the optical lens clean, the air purge collar accessory is recommended, OS136-AP (Fig 3-3). The following figures show the Mounting Bracket (OS136-MB), Air Purge Collar (OS136-AP), Stainless Steel Housing, Water/Air Cool Jacket (OS136-WC), and the Water/Air Cool Jacket Assembly. 12.7 3.2 (0.5) (1/8) 12.7 (0.5) 50.0 90° (1.97) Ø
Summary of the content on the page No. 10
3 Operation 3/4-16 UNF LIGHT HEX KNURL 4.76 (3/16) WIDE 33.27 (1.31) 88.9 (3.5) 1.83m (6ft) DIMENSIONS mm (in) Figure 3-4. Stainless Steel Housing 1/8 NPT COMPRESSION 7.62 FITTING, 2 PLCS. (0.30) INLET OUTLET 85.09 (3.35) 3/4-16 UNF-2B 3/4-16 UNF Dimensions mm (in.) Figure 3-5. Water/Air Cool Jacket, OS136-WC MOUNTING NUT MOUNTING BRACKET OS137 INTLET OUTLET UP TO 200°C (392°F) AMBIENT TEMPERATURE WITH WATER COOLING Dimensions mm (in.) Figure 3-6. Water/Air Cool Jacket Assembly 5 19.05 (0.75)
Summary of the content on the page No. 11
Laser Sight Accessory 4 SECTION 4 - LASER SIGHT ACCESSORY 4.1 – Warning and Caution CAUTION: You may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: � USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MAY RESULT IN HAZARDOUS RADIATION EXPOSURE. � DO NOT LOOK AT THE LASER BEAM COMING OUT OF THE LENS OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS – EYE DAMAGE CAN RESULT. � USE EXTREME CAUTION WHEN OPERATING THE LASER
Summary of the content on the page No. 12
Laser Sight Accessory 4 LASER WARNING LABEL DC POWER JACK OS136 LED LASER POWER LASER INDICATOR 19 BEAM (0.75) ON/OFF 50.8 SWITCH (2.0) POWER CABLE BATTERY PACK Dimensions mm (in.) POWER SUPPLY Figure 4-1. Laser Sighting Accessory, OS100-LS ® LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. CLASS 2 CAUTION LASER PRODUCT. AVOID EXPOSURE. LASER RADIATION IS EMITTED LASER RADIATION - DO NOT STARE INTO BEAM FROM THIS APERTURE. OUTPUT <1 mW, WAVELENGTH 630-670
Summary of the content on the page No. 13
Specifications 5 SECTION 5 – SPECIFICATIONS 5.1 - General Temperature Range: OS136-1 -18 to 204ºC (0 to 400ºF) OS136-2 149 to 538ºC (300 to 1000ºF) Accuracy: @22ºC (72ºF) ambient OS136-1 3% of Rdg or 4.4ºC (8ºF) whichever is greater OS136-2 3% of Rdg or 5.5ºC (10ºF) whichever is greater From 185 to 510ºC (365 to 950ºF) Repeatability: 1% of Rdg. Optical Field of View: 6 to 1 (Distance to Spot Size) Spectral Response: 5 to 14 microns Response Time: 150 msec, 0 to 63% of final value Emissivity: Fix
Summary of the content on the page No. 14
5 Specifications 5.2 - Laser Sight Accessory Laser Wavelength (Color): 630 - 670 nm (Red) Operating Distance: Up to 9.1 m (30 ft.) Max. Laser Power Output: Less than 1 mW @ 22ºC ambient European Classification: Class 2, EN60825-1/11.2001 FDA Classification: Class II Laser Product. Complies with 21 CFR 1040.10 Laser Beam Diameter: Less than 5 mm Beam Divergence: Less than 2 mrad Operating Temperature: 0 to 50°C (32 to 122°F) Operating Relative Humidity: Less than 95% RH, non-condensing Power Swit
Summary of the content on the page No. 15
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department w
Summary of the content on the page No. 16
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! SM Shop online at omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Acce