Emerson PN 51A-499ACL01/rev.K user manual

User manual for the device Emerson PN 51A-499ACL01/rev.K

Device: Emerson PN 51A-499ACL01/rev.K
Category: Stud Sensor
Manufacturer: Emerson
Size: 0.29 MB
Added : 8/28/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson PN 51A-499ACL01/rev.K. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson PN 51A-499ACL01/rev.K.

For your convenience

If looking through the Emerson PN 51A-499ACL01/rev.K user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson PN 51A-499ACL01/rev.K on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson PN 51A-499ACL01/rev.K to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson PN 51A-499ACL01/rev.K User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson PN 51A-499ACL01/rev.K but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson PN 51A-499ACL01/rev.K. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Sheet
PN 51A-499ACL01/rev.K
September 2010
Model 499A CL-01
Free Chlorine Sensor
For additional information, please visit our website
at www.emersonprocess.com/raihome/liquid/.
CAUTION CAUTION
Do not exceed pressure and temperature specifications.
SENSOR/PROCESS APPLICATION COMPATIBILITY
Pressure: 65 psig max (549 kPa abs max)
The wetted sensor materials may not be compatible
Temperature: 32 to 122°F (0 to 50°C)
with process com position and operating conditions.
Application compat

Summary of the content on the page No. 2

MODEL 499A CL-01 INSTALLATION INSTALLATION Install the sensor in a flowing sample. Keep the sample flow as constant as possible at a value within the limits below. Flow through 1 to 5 gpm (3.8 to 19 L/min) Open channel 1 ft/sec (0.3 m/sec) Low flow cell (PN 24091-00) 8 to 15 gph (30 to 57 L/hr) Low flow cell (PN 24091-01) 2 to 3 gph (120 to 190 mL/min) FIGURE 1. Sensor Orientation FIGURE 3. Flow-Through 2 in. Tee FIGURE 2. Flow-Through 1-1/2 in. Tee PN 24091-01 has bubble sweeping nozzle for

Summary of the content on the page No. 3

MODEL 499A CL-01 WIRING WIRING FIGURE 6. Wiring Sensor with Optimum EMI/RFI or FIGURE 5. Wiring Sensor with Standard Cable to Variopol Cable to Model 1056 and Model 56 Analyzer Model 1056 and Model 56 Analyzer FIGURE 8. Wiring Sensor with Optimum EMI/RFI or FIGURE 7. Wiring Sensor with Standard Cable to Variopol Cable to Model 54eA Analyzer Model 54eA Analyzer 3

Summary of the content on the page No. 4

MODEL 499A CL-01 WIRING FIGURE 9. Wiring Sensor with Standard Cable to FIGURE 10. Wiring Sensor with Optimum EMI/RFI or Model 5081-A Transmitter. Variopol Cable to Model 5081-A Transmitter. FIGURE 11. Wiring Sensor with Standard Cable to FIGURE 12. Wiring Sensor with Optimum EMI/RFI or Model Xmt-A Transmitter. Variopol Cable to Model Xmt-A Transmitter. 4

Summary of the content on the page No. 5

MODEL 499A CL-01 WIRING FIGURE 14. Wiring Sensor with Optimum EMI/RFI or FIGURE 13. Wiring Sensor with Standard Cable to Variopol Cable to Model 1066 Transmitter. Model 1066 Transmitter. When making connections through a junction box (PN 23550-00), wire point-to-point. NOTE: Use a wire nut and pigtail (included) when connecting several wires to the same terminal. FIGURE 15. Pin Out Diagram for Model 499ACL- VP Sensor (top view of connector end of sensor) CALIBRATION Full Scale: Because stable

Summary of the content on the page No. 6

MODEL 499A CL-01 MAINTENANCE MAINTENANCE Periodic maintenance and cleaning are required for best performance of the sensor. Generally, the membrane and fill solution should be replaced every one to three months. If the sensor is being used in water having conductivity less than about 100 µS/cm, it might be necessary to replace the fill solution (but not the membrane) more often. Sensors installed in harsh or dirty environments require more frequent maintenance. The optimum maintenance frequency

Summary of the content on the page No. 7

MODEL 499A CL-01 MAINTENANCE A wooden ring rests inside the membrane assembly. It is not shown in the drawing. FIGURE 16. Sensor Parts SPARE PARTS 33523-00 Electrolyte Fill Plug 9550094 O-Ring, Viton 2-014 33521-00 Membrane Retainer 23501-08 Free Chlorine Membrane Assembly: includes one membrane assembly and one O-ring 23502-08 Free Chlorine Membrane Kit: includes 3 membrane assemblies and 3 O-rings 9210356 #4 Free Chlorine Sensor Fill Solution, 4 oz (120 mL) 7

Summary of the content on the page No. 8

The right people, the right answers, ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE right now. http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com © Rosemount Analytical Inc. 2010 8


Alternative user manuals
# User manual Category Download
1 Emerson 142 User manual Stud Sensor 1
2 Emerson 396R User manual Stud Sensor 3
3 Emerson 396RVP User manual Stud Sensor 1
4 Emerson 228 User manual Stud Sensor 4
5 Emerson 396VP User manual Stud Sensor 0
6 Emerson 141 User manual Stud Sensor 0
7 Emerson 396 User manual Stud Sensor 0
8 Emerson 397 User manual Stud Sensor 0
9 Emerson 140 User manual Stud Sensor 0
10 Emerson 398 User manual Stud Sensor 0
11 Emerson CMF200A User manual Stud Sensor 25
12 Emerson 399VP User manual Stud Sensor 3
13 Emerson 398VP User manual Stud Sensor 0
14 Emerson 400 User manual Stud Sensor 6
15 Emerson 400 VP User manual Stud Sensor 4
16 A&D sf/sg User manual Stud Sensor 2
17 Sony ICX423AL User manual Stud Sensor 1
18 Sony E01X23A41 User manual Stud Sensor 1
19 Sony ICX418ALB User manual Stud Sensor 1
20 Agilent Technologies 81680A User manual Stud Sensor 3