Emerson 400 VP user manual

User manual for the device Emerson 400 VP

Device: Emerson 400 VP
Category: Stud Sensor
Manufacturer: Emerson
Size: 0.4 MB
Added : 8/28/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 400 VP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 400 VP.

For your convenience

If looking through the Emerson 400 VP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 400 VP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 400 VP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 400 VP User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 400 VP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 400 VP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Sheet
PN 51A-400/rev.R
Model 400 and 400 VP
December 2010

ENDURANCE Conductivity Sensors
For additional information, please refer visit our website at
www.emersonprocess.com/raihome/liquid/.
CAUTION
SENSOR/PROCESS
WARNING
WARNING
APPLICATION COMPATIBILITY
Before removing the sensor, be absolutely certain
The wetted sensor materials may not be compatible
that the process pressure is reduced to 0 psig and
with process com position and operating conditions.
the process temperature is

Summary of the content on the page No. 2

MODEL 400 and 400VP WIRING ° ° FIGURE 1. Sensor Orientation FIGURE 2. Direct Insertion in a Pipe FIGURE 3. Insertion in a Pipe Tee FIGURE 4. Insertion in a Pipe Tee FIGURE 5. Insertion in a Pipe Tee FIGURE 6. Insertion in a Flow Cell (PN 24091-02) 2

Summary of the content on the page No. 3

MODEL 400 and 400VP WIRING WIRING WIRE COLOR AND CONNECTIONS IN SENSOR COLOR FUNCTION Gray Connects to outer electrode Clear Coaxial shield for gray wire Orange Connects to inner electrode Clear Coaxial shield for orange wire Red RTD in White with red stripe RTD RTD sense White RTD return Clear Shield for all RTD lead wires WIRING DIAGRAMS FIGURE 8. Model 56 and 1056 Wiring FIGURE 7. Model 54eC Wiring 3

Summary of the content on the page No. 4

MODEL 400 and 400VP WIRING TB2 TB1 RTN WHITE RCV B SENSE WHITE/RED RCV A RTD IN RED CLEAR RSHLD SHLD CLEAR GRAY DRVB ORANGE DRVA CLEAR DSHLD FIGURE 9. Model 1066 Wiring FIGURE 10. Model Xmt-C-10 Wiring (Panel) FIGURE 11. Model Xmt-C-11 Wiring (Pipe or Wall) FIGURE 12. Model 5081C Wiring FIGURE 13. Model 6081-C Wiring 4

Summary of the content on the page No. 5

MODEL 400 and 400VP WIRING WIRING THROUGH A JUNCTION BOX Model 400-60 sensors have a junction box mounted on the end of the sensor. See Figure 14 for wiring instructions. If wiring connections are made through a remote junction box (PN 23550-00), wire point-to-point. Use cable 23747-00 (factory-terminated) or 9200275 (raw cable). PIN OUT DIAGRAM FOR 400VP FIGURE 15. VP pin-out (viewed from connector end of sensor, looking down) NOTES: 1. THE GRAY SENSOR WIRE IS CONNECTED TO THE JUNCTION BOX, W

Summary of the content on the page No. 6

MODEL 400 and 400VP WIRING TROUBLESHOOTING PROBLEM PROBABLE CAUSE SOLUTION Off-scale reading Wiring is wrong. Verify wiring. Temperature element is open or shorted. Check temperature element for open or short circuits. See Figure 16. Sensor is not in process stream. Be sure sensor is completely submerged in process stream. Variopol cable is not properly seated. Loosen connector and reseat. Sensor has failed. Perform isolation checks. See Figure 17. Noisy reading Sensor is improperly installed

Summary of the content on the page No. 7

NOTES 7

Summary of the content on the page No. 8

The right people, the right answers, ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE right now. http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com © Rosemount Analytical Inc. 2010 8


Alternative user manuals
# User manual Category Download
1 Emerson 142 User manual Stud Sensor 1
2 Emerson 396R User manual Stud Sensor 3
3 Emerson 396RVP User manual Stud Sensor 1
4 Emerson 228 User manual Stud Sensor 4
5 Emerson 396VP User manual Stud Sensor 0
6 Emerson 141 User manual Stud Sensor 0
7 Emerson 396 User manual Stud Sensor 0
8 Emerson 397 User manual Stud Sensor 0
9 Emerson 140 User manual Stud Sensor 0
10 Emerson 398 User manual Stud Sensor 0
11 Emerson CMF200A User manual Stud Sensor 25
12 Emerson 399VP User manual Stud Sensor 3
13 Emerson 398VP User manual Stud Sensor 0
14 Emerson 400 User manual Stud Sensor 6
15 Emerson Combination pH/ORP Sensor User manual Stud Sensor 0
16 A&D sf/sg User manual Stud Sensor 2
17 Sony ICX423AL User manual Stud Sensor 1
18 Sony E01X23A41 User manual Stud Sensor 1
19 Sony ICX418ALB User manual Stud Sensor 1
20 Agilent Technologies 81680A User manual Stud Sensor 3