Emerson 398VP user manual

User manual for the device Emerson 398VP

Device: Emerson 398VP
Category: Stud Sensor
Manufacturer: Emerson
Size: 0.97 MB
Added : 8/28/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 398VP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 398VP.

For your convenience

If looking through the Emerson 398VP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 398VP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 398VP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 398VP User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 398VP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 398VP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
PN 51-396/397/398/rev.L
Models 396/396VP/397/398/398VP
November 2010
pH/ORP Sensors
MODEL 396 and
MODEL 398
MODEL 397
MODEL 396VP and
MODEL 398VP

Summary of the content on the page No. 2

DANGER ESSENTIAL INSTRUCTIONS HAZARDOUS AREA INSTALLATION READ THIS PAGE BEFORE PROCEEDING! This sensor is not Intrinsically Safe. or Rosemount Analytical designs, manufactures, and tests its products to meet Explosion Proof. Installations near flammable many national and international standards. Because these instruments are sophisticated technical products, you must properly install, use, and main- liquids or in hazardous area locations must be tain them to ensure they continue to operate wit

Summary of the content on the page No. 3

MODEL 396/396VP/397/398/398VP TABLE OF CONTENTS TUpH MODELS 396/396VP/397/398/398VP pH/ORP SENSORS TABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICATIONS ......................................................... 1 1.1 TUpH™ Features and Applications.................................................................. 1 1.2 Performance and Physical Specifications ........................................................ 3 1.3 Ordering Information .....................................

Summary of the content on the page No. 4

MODEL 396/396VP/397/398/398VP TABLE OF CONTENTS LIST OF FIGURES Number Title Page 1-1 Cross Section Diagram of the TUpH Reference Technology............. 2 2-1 Flow Through/Insertion Installation for Models 396, 396VP, 398, & 398VP .............. 10 2-2 Dimensional Drawing For Models 396 & 398.......................................................... 11 2-3 Dimensional Drawing For Models 396VP & 398VP ................................................ 12 2-4 Submersion Installations For Models 396

Summary of the content on the page No. 5

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTIONS AND SPECIFICATIONS SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.1 TUpH™ FEATURES AND APPLICATIONS. mounting configurations. The Model 396 features an optional front or rear 1 in. MNPT process connection Rosemount Analytical has achieved a new industry for insertion, submersion, or flow through applications. standard for the life expectancy of pH sensors with the TUpH Sensors. The low maintenance, disposable 1.1.2 Model 397 TUpH and Models 39

Summary of the content on the page No. 6

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTIONS AND SPECIFICATIONS FIGURE 1-1. Cross Section Diagram of the TUpH Reference Technology All TUpH sensors are designed with a large area reference junction, helical reference pathway, and an AccuGlass pH glass bulb. This sensor technology ensures superior performance while only requiring minimal maintenance. 2

Summary of the content on the page No. 7

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.2 PERFORMANCE & PHYSICAL SPECIFICATIONS SPECIFICATIONS MODELS 396 &396VP MODELS 398 & 398VP MODEL 397 QUIK-LOC KIT Measurements pH: 0-14 pH: 0-14 pH: 0-14 — and Ranges ORP: -1500 to 1500 mv Available pH GPHT hemi bulb or GPHT hemi bulb or GPHT hemi bulb — ACCUGLASSTypes GPLR flat bulb GPLR flat bulb Wetted Materials 316 SST, Polypropylene, Titanium, Tefzel, glass, Polypropylene, EP, glass 316 SST, EP, PEEK EPDM, glass c

Summary of the content on the page No. 8

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.3 ORDERING INFORMATION The Model 396 pH Sensor features your selection of glass electrode type, either the standard hemi bulb or the optional flat glass electrode combined with the coating resistant, polypropylene reference with gel filled electrolyte. The sensor is housed in a stainless steel body and is used with a 1 in. MNPT threaded process connector suitable for insertion, submersion, or flow through installations. T

Summary of the content on the page No. 9

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS The Model 398 Sensor, housed in a titanium tube and made with a Tefzel reference junction, can be used with a 1 inch MNPT process connector (purchased separately). The sensor is available with a hemi bulb glass pH electrode or a platinum and glass ORP electrode and with Pt100 or 3K temperature compensation. The 398 is provided with a standard 15 ft cable. A preamplifier must be used if the sensor is more than 15 ft from the

Summary of the content on the page No. 10

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS The TUpH Model 397 pH Sensor is housed in a polypropylene body and is designed to be used with the Quik-Loc Kit. The sensor includes a large general purpose (GPHT) glass pH electrode and a large area polypropylene reference junction with gel filled reference electrolyte. The Model 397 is available without an integral preamplifier only and 15 ft (4.6 m) of cable. MODEL 397 TUpH pH SENSOR CODE PREAMPLIFIER/CABLE (Required S

Summary of the content on the page No. 11

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS FOR FIRST TIME 396, 396VP, 398, AND 398VP INSTALLATIONS, ROSEMOUNT ANALYTICAL RECOMMENDS USING THE FOLLOWING GUIDE: 1. Process Connector Accessories (required for all first time installations with 1-inch process connection threads) Choose one: PN 23166-00, 316 SST, 1 in. x 1 in. NPT process connector, with EPDM o-ring PN 23166-01, Titanium, 1 in. x 1 in. NPT process connector, with EPDM o-ring PN 9510066, Nylon, 1 in. x

Summary of the content on the page No. 12

MODEL 396/396VP/397/398/398VP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS ADDITIONAL ACCESSORIES FOR MODEL 396, 396VP, 398 AND 398VP TUpH SENSORS PART NUMBER DESCRIPTION 33046-00 Ferrule 1 in., split 316 SS 33211-00 Adapter retrofit for PN 915240-04 9550167 EPDM O-ring for process connector (PN 23166-00) 1 9310100 Ferrule, 1 in. Teflon 9310096 Nut, Swage, 1 in. stainless steel 9550167 O-ring, 2-214 EPDM 1 Teflon is a registered trademark of E.I. du Pont de Nemours & Co. ADDITIONAL ACCESSORIES FO

Summary of the content on the page No. 13

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION SECTION 2.0 INSTALLATION 2.2.1 Flow Through and Insertion Mounting for 2.1 UNPACKING AND INSPECTION. Inspect the out- Models 396, 396VP, 398, and 398VP. The Models 396, side of the carton for any damage. If damage is detect- 396VP, 398, and 398VP Sensors can be used with a 1 ed, contact the carrier immediately. Inspect the instru- inch MNPT process connector at the front of the sensor ment and hardware. Make sure all the items in the pack- f

Summary of the content on the page No. 14

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION Once the adapter has been properly placed in the coupler, Wrap the pipe threads of the Twin-Kam Kamloc coupler both arms should be positioned in the locked position. A Sur- with Teflon tape before placing it into the process pipe. The ™ 1 Loc spring arm has been provided on one arm so that the coupler can be connected to any 1 in. process connection 2 “arm cannot be opened until the spring is released.” and must be mounted within 80° of vert

Summary of the content on the page No. 15

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION MILLIMETER INCH DWG. NO. REV. 40039601 J FIGURE 2-2. Dimensional Drawing For Models 396 and 398 11

Summary of the content on the page No. 16

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION INCH MILLIMETER The metal process connector gives the sensor var- Metal Process Connector PN 23166-xx ious insertions depths, depending on where the (xx = 00 for 316 SST and xx = 01 for tita- user locates the compression fitting. Also the nium) can be used for insertion or sub- threads can be switched to face the cable end of mersion mounting of Models 396VP or the sensor for connection to submersion pipes. 398VP sensors in 1-inch fittings.

Summary of the content on the page No. 17

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION MILLIMETER INCH P.N. 23166-00, 23166-01, OR 9510066 DWG. NO. REV. 40039603 C DWG. NO. REV. 40039604 D DWG. NO. REV. 40039602 D FIGURE 2-4. Submersion Installations for Models 396, 396VP, 398, and 398VP. 13

Summary of the content on the page No. 18

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION MILLIMETER INCH DWG. NO. REV. 40039702 C NOTE: The EP gasket (see drawing #40039702) provided with the coupler should be periodically inspected. If gasket shows signs of corrosion, DWG. NO. REV. replacement will be necessary to ensure a proper and secure seal between the coupler and adapter. 40039704 B DWG. NO. REV. 40039701 C FIGURE 2-5. Dimensional Drawings For Model 397 in the Quik-Loc Unit 14

Summary of the content on the page No. 19

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION DWG. NO. REV. 40039703 B FIGURE 2-6. Recommended Flow-Through and Insertion Installation For Model 397 2.3 ELECTRICAL INSTALLATION. The Models 396, 396VP, 397, 398, and 398VP are for use Please refer to Figures 2-19 thru 2-36 for wiring Models with a remote preamplifier. Each sensor comes with either a 396VP and 398VP. special 15 ft low noise coax cable or a Variopol (VP) con- nector, which is used with a mating Variopol cable. The DANGER ca

Summary of the content on the page No. 20

MODEL 396/396VP/397/398/398VP SECTION 2.0 INSTALLATION DWG. NO. REV. 40039610 D DWG. NO. REV. 40039706 B FIGURE 2-9. Wiring Details For Model 396-54 (50), 397-54 (50), and 398-54 (50). For Use With Junction Box (PN 23309-04 (03)) and Remote Preamplifier 16


Alternative user manuals
# User manual Category Download
1 Emerson 142 User manual Stud Sensor 1
2 Emerson 396R User manual Stud Sensor 3
3 Emerson 396RVP User manual Stud Sensor 1
4 Emerson 228 User manual Stud Sensor 4
5 Emerson 396VP User manual Stud Sensor 0
6 Emerson 141 User manual Stud Sensor 0
7 Emerson 396 User manual Stud Sensor 0
8 Emerson 397 User manual Stud Sensor 0
9 Emerson 140 User manual Stud Sensor 0
10 Emerson 398 User manual Stud Sensor 0
11 Emerson CMF200A User manual Stud Sensor 25
12 Emerson 399VP User manual Stud Sensor 3
13 Emerson 400 User manual Stud Sensor 6
14 Emerson 400 VP User manual Stud Sensor 4
15 Emerson Combination pH/ORP Sensor User manual Stud Sensor 0
16 A&D sf/sg User manual Stud Sensor 2
17 Sony ICX423AL User manual Stud Sensor 1
18 Sony E01X23A41 User manual Stud Sensor 1
19 Sony ICX418ALB User manual Stud Sensor 1
20 Agilent Technologies 81680A User manual Stud Sensor 3