Emerson 399VP user manual

User manual for the device Emerson 399VP

Device: Emerson 399VP
Category: Stud Sensor
Manufacturer: Emerson
Size: 0.81 MB
Added : 8/28/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 399VP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 399VP.

For your convenience

If looking through the Emerson 399VP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 399VP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 399VP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 399VP User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 399VP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 399VP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
PN 51-399VP/rev.B
January 2005
Model 399VP
Combination pH/ORP Sensor

Summary of the content on the page No. 2

DANGER ESSENTIAL INSTRUCTIONS HAZARDOUS AREA INSTALLATION READ THIS PAGE BEFORE PROCEEDING! Installations near flammable liquids or in haz- Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards. Because these instru- ardous area locations must be carefully evalu- ments are sophisticated technical products, you must properly install, use, ated by qualified on site safety personnel. This and maintain them to ensure they continue to ope

Summary of the content on the page No. 3

MODEL 399VP pH/ORP TABLE OF CONTENTS MODEL 399VP pH/ORP SENSOR TABLE OF CONTENTS SECTION TITLE PAGE 1.0 DESCRIPTION AND SPECIFICATIONS .......................................................... 1 1.1 Features and Applications................................................................................. 1 1.2 Physical Specifications...................................................................................... 1 1.3 Ordering Information ..................................................

Summary of the content on the page No. 4

MODEL 399VP pH/ORP TABLE OF CONTENTS MODEL 399VP pH/ORP SENSOR LIST OF FIGURES Figure No. Title Page 2-1 Sensor Dimensions ........................................................................................... 4 2-2 Model 399VP Shown in Various Flow-Through Installations............................. 5 2-3 Model 399VP Shown in Low Flow Cell Assembly ............................................. 6 2-4 Model 399VP Shown in Various Insertion Installations ..................................... 6

Summary of the content on the page No. 5

MODEL 399VP pH/ORP SENSOR SECTION 1.0 DESCRIPTION AND SPECIFICATIONS SECTION 1.0. DESCRIPTION AND SPECIFICATIONS 1.1 FEATURES AND APPLICATIONS 1.2 PHYSICAL SPECIFICATIONS 1.3 ORDERING INFORMATION 1.1 FEATURES AND APPLICATIONS 1.2 PHYSICAL SPECIFICATIONS The Rosemount Analytical Model 399VP Sensor meas- Materials of Construction: Tefzel, glass, ceramic ures the pH or the Oxidation Reduction Potential and Viton (also, Platinum for ORP sensor) (ORP) of aqueous solutions in pipelines, ope

Summary of the content on the page No. 6

MODEL 399VP pH/ORP SENSOR SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.3 ORDERING INFORMATION The Model 399VP pH/ORP Sensor is available with custom glass electrodes housed in a molded Tefzel body with 1 in. MNPT threads suitable for insertion, submersion or flow through installation. The sensor includes a general purpose hemi bulb pH electrode (flat bulb optional) or a platinum ORP electrode and a double or triple junction gel filled reference electrode. Automatic temperature compensation is s

Summary of the content on the page No. 7

MODEL 399VP pH/ORP SENSOR SECTION 2.0 INSTALLATION SECTION 2.0. INSTALLATION 2.1 UNPACKING AND INSPECTION 2.2 MOUNTING 2.3 FLOW-THROUGH INSTALLATIONS 2.4 INSERTION INSTALLATIONS 2.5 SUBMERSION INSTALLATIONS 2.1 UNPACKING AND INSPECTION. 2.2 MOUNTING. Inspect the carton for any damage. If damage is The sensor has been designed to be located in detected, contact the carrier immediately. Inspect the industrial process environments. Temperature and hardware. Make sure all the items on the

Summary of the content on the page No. 8

MODEL 399VP pH/ORP SENSOR SECTION 2.0 INSTALLATION INCH MILLIMETER FIGURE 2-1. Sensor Dimensions 4

Summary of the content on the page No. 9

MODEL 399VP pH/ORP SENSOR SECTION 2.0 INSTALLATION 2.3 FLOW-THROUGH INSTALLATIONS. The Model 399VP Sensor has a 1 in. MNPT process connection at the front and back end of the sensor for mount- ing directly into a 1 in. or 1½ in. tee. See Figure 2-2 for installation configurations. It is recommended that shut-off valves be provided for sensor removal and service. NOTE Large pipe wrenches must not be used to tighten the sensor into a flange or other type of mounting. Model 399VP shown in Tee PN

Summary of the content on the page No. 10

MODEL 399VP pH/ORP SENSOR SECTION 2.0 INSTALLATION The see-through flow cell is perfect for processes where flow regulation is desired. Tubing (1/4 inch) is needed for connection to the process or sample stream. FIGURE 2-3. MODEL 399VP SHOWN IN LOW FLOW CELL ASSEMBLY (PN 23728-00) 2.4 INSERTION INSTALLATIONS. The Model 399VP sensor has forward and rear facing 1 in. MNPT process connections for pipeline installations (see Figure 2-4 or 2-5) and flange connections. The Model 399VP is also suitabl

Summary of the content on the page No. 11

MODEL 399VP pH/ORP SENSOR SECTION 2.0 INSTALLATION The Insertion Adapter mounts Model 399VP into a 1-1/2 inch NPT process pipe. Unscrewing the hex nut allows easy sensor removal without twisting the sensor cable. FIGURE 2-5. MODEL 399VP WITH INSERTION ADAPTER (PN 23242-02) 2.5 SUBMERSION INSTALLATIONS. The Model 399VP Sensor has a 1 in. MNPT process connection at the back of the sensor (see Figure 2-1). Utilizing a standard 1 in. union (such as PN 9330022), the sensor may be mounted to a 1 in.

Summary of the content on the page No. 12

MODEL 399VP pH/ORP SENSOR SECTION 2.0 INSTALLATION HANDRAIL MOUNTING KIT (PN 1000857) The Handrail Mounting Kit does not include a pull box, pipe, or coupling. Sensor and junction box are sold separately. FIGURE 2-6. SENSOR SHOWN IN HANDRAIL MOUNTING ASSEMBLY (PN 11275-01) The Handrail Mounting Assembly can be used in applications where Model 399VP needs to be placed in a pond, tank, aer- ation basin, or open channel. Handrail Mounting Assembly includes all parts seen in drawing; sensor is sold

Summary of the content on the page No. 13

MODEL 399VP pH/ORP SENSOR SECTION 2.0 INSTALLATION The Jet Spray Cleaner eliminates routine manual sensor maintenance by cleaning Model 399VP with water or compressed air. Flow through the cleaner can be controlled FIGURE 2-7. JET SPRAY CLEANER (PN 12707-00) by a solenoid valve. (Model 399 with integral USED WITH MODEL 399VP cable shown) The Pipe Mount Union Accessory (PN 9330022) is ideal for connecting Model 399VP to a pipe for insertion into a pond, tank, aeration basin, or open channel. FIGU

Summary of the content on the page No. 14

MODEL 399VP pH/ORP SENSOR SECTION 3.0 WIRING SECTION 3.0. WIRING Figures 3-2 thru 3-23 provide the diagrams for wiring NOTE the 399VP sensor to various analyzer/transmitters. When extending the mV signal from the sensor 1. If the cable needs to be extended, use a high quali- through a remote junction box to the analyzer, ty cable available from Rosemount Analytical. Refer the outer braid of the extension cable to the to Figures 3-2 through 3-23 for the appropriate junc- instrument must be te

Summary of the content on the page No. 15

MODEL 399VP pH/ORP SENSOR SECTION 3.0 WIRING MODEL 399VP FIGURE 3-1. Wire and Connector Pin Functions FIGURE 3-2. Model 81 Wiring FIGURE 3-3. Model 1181 Wiring FIGURE 3-4. Model 54 Wiring through Remote Junction Box 11

Summary of the content on the page No. 16

MODEL 399VP pH/ORP SENSOR SECTION 3.0 WIRING FIGURE 3-5. Model 54 Wiring FIGURE 3-6. Model 2081 Wiring FIGURE 3-8. Model 2081 Wiring through FIGURE 3-7. Model 1181, 1050/1060, and Remote Junction Box 1003/1023 Wiring through Remote Junction Box 12

Summary of the content on the page No. 17

MODEL 399VP pH/ORP SENSOR SECTION 3.0 WIRING FIGURE 3-10. Model 3081 & 4081 Wiring through FIGURE 3-9. Model 81 Wiring through Remote Junction Box Remote Junction Box FIGURE 3-11. Model 1055-22-32 Wiring FIGURE 3-12. Model 3081 & 4081 Wiring 13

Summary of the content on the page No. 18

MODEL 399VP pH/ORP SENSOR SECTION 3.0 WIRING FIGURE 3-14. Model 1054A/B and 2054 Wiring FIGURE 3-13. Model 1054 Wiring FIGURE 3-16. Model 1054A/B & 2054 Wiring FIGURE 3-15. Model 1054 Wiring through through a Remote Junction Box a Remote Junction Box 14

Summary of the content on the page No. 19

MODEL 399VP pH/ORP SENSOR SECTION 3.0 WIRING FIGURE 3-17. Model SCL-(P/Q) Wiring FIGURE 3-18. Model 2700 Wiring FIGURE 3-19. Model 54epH Wiring FIGURE 3-20. Model 1055-22-32 Wiring through Remote Junction Boxes 15

Summary of the content on the page No. 20

MODEL 399VP pH/ORP SENSOR SECTION 3.0 WIRING DWG. NO. REV. 41055107 C FIGURE 3-21. Wiring Model 399VP-09, 400, 401, 402, 403, and 404 to Model 1055 (Pipe/Wall Mount). 16


Alternative user manuals
# User manual Category Download
1 Emerson 142 User manual Stud Sensor 1
2 Emerson 396R User manual Stud Sensor 3
3 Emerson 396RVP User manual Stud Sensor 1
4 Emerson 228 User manual Stud Sensor 4
5 Emerson 396VP User manual Stud Sensor 0
6 Emerson 141 User manual Stud Sensor 0
7 Emerson 396 User manual Stud Sensor 0
8 Emerson 397 User manual Stud Sensor 0
9 Emerson 140 User manual Stud Sensor 0
10 Emerson 398 User manual Stud Sensor 0
11 Emerson CMF200A User manual Stud Sensor 25
12 Emerson 398VP User manual Stud Sensor 0
13 Emerson 400 User manual Stud Sensor 6
14 Emerson 400 VP User manual Stud Sensor 4
15 Emerson Combination pH/ORP Sensor User manual Stud Sensor 0
16 A&D sf/sg User manual Stud Sensor 2
17 Sony ICX423AL User manual Stud Sensor 1
18 Sony E01X23A41 User manual Stud Sensor 1
19 Sony ICX418ALB User manual Stud Sensor 1
20 Agilent Technologies 81680A User manual Stud Sensor 3