Emerson 396R user manual

User manual for the device Emerson 396R

Device: Emerson 396R
Category: Stud Sensor
Manufacturer: Emerson
Size: 1.3 MB
Added : 8/28/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 396R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 396R.

For your convenience

If looking through the Emerson 396R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 396R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 396R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 396R User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 396R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 396R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
PN 51-396R/rev.J
Model 396R and 396RVP
February 2011
Retractable pH/ORP Sensors

Summary of the content on the page No. 2

DANGER ESSENTIAL INSTRUCTIONS HAZARDOUS AREA INSTALLATION READ THIS PAGE BEFORE PROCEEDING! Installations near flammable liquids or in hazardous Rosemount Analytical designs, manufactures, and tests its products to area locations must be carefully evaluated by qualified meet many national and international standards. Because these instru- on site safety personnel. This sensor is not Intrinsically ments are sophisticated technical products, you must properly install, Safe or Explosion Proof. use

Summary of the content on the page No. 3

MODEL 396R pH/ORP TABLE OF CONTENTS MODEL 396R AND 396RVP RETRACTABLE pH/ORP SENSORS TABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICATIONS........................................................... 1 1.1 Features and Applications................................................................................. 1 1.2 Performance and Physical Specifications ......................................................... 2 1.3 Ordering Information .......................................

Summary of the content on the page No. 4

MODEL 396R pH/ORP TABLE OF CONTENTS LIST OF FIGURES Figure No. Title Page 1-1 Cross Section Diagram of the TUpH Reference Technology ............................ 1 2-1 Exploded View of Ball Valve Kit PN 23240-00 used with process connector . PN 23166-00 (or PN 23166-01) ........................................................................ 7 2-2 Typical Mounting Configurations for Model 396R ............................................. 8 2-3 Typical Mounting Configurations for Model 396RVP.

Summary of the content on the page No. 5

MODEL 396R pH/ORP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS SECTION 1.0 DESCRIPTION AND SPECIFICATIONS Transmitter. The Model 396R is compatible with all 1.1 FEATURES AND APPLICATIONS Rosemount Analytical and various other manufacturers The Model 396R and 396RVP Sensors are specifically instruments. designed for improved life in harsh, dirty applications where The entire line of TUpH model sensors now incorporate a separate sample stream is difficult to provide and greater 1 the new SILCORE tec

Summary of the content on the page No. 6

MODEL 396R pH/ORP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.2 PERFORMANCE AND PHYSICAL SPECIFICATIONS MODEL 396R MODEL 396RVP Measured Range: Measured Range: ORP: -1500 to 1500mV ORP: -1500 to 1500mV pH: 0 to 14 pH: 0 to 14 Percent Linearity Over pH Range: Available pH glass types: GPLR hemi bulb or flat bulb Hemi Bulb Flat Bulb Wetted Materials: Polypropylene, EPDM, titanium, 0-2 pH 94% 93% glass, (platinum: ORP

Summary of the content on the page No. 7

MODEL 396R pH/ORP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.3 ORDERING INFORMATION The Model 396R Sensor is housed in a titanium tube, with a polypropylene reference junction and titanium solu- tion ground for use with a ball valve (order separately) for hot tap applications. The sensor is available with either a hemi or flat glass pH electrode and features a shrouded glass/platinum electrode and PT100 or 3K temperature compensation. The 396R is available with 9.5 in. or 15 ft of integral cab

Summary of the content on the page No. 8

MODEL 396R pH/ORP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS TABLE 1-1. COMMONLY USED ACCESSORIES FOR MODEL 396R For first time installations, Rosemount Analytical recommends using the following guide 1. Retractable Mounting A. Choose one (required for all first time installations): PN 23166-00, 1 in. x 1 in. NPT process connector, 316 SST PN 23166-01, 1 in. x 1 in. NPT process connector, Titanium B. Choose one: PN 23240-00, 1-1/2 in. ball valve assembly, 316 SST PN 23765-00, 1-1/4 in. ball v

Summary of the content on the page No. 9

MODEL 396R pH/ORP SECTION 1.0 DESCRIPTION AND SPECIFICATIONS TABLE 1-3. COMMONLY USED ACCESSORIES FOR MODEL 396RVP FOR FIRST TIME 396RVP AND 398RVP INSTALLATIONS, ROSEMOUNT ANALYTICAL RECOMMENDS USING THE FOLLOWING GUIDE: 1. Variopol Cable (required for all first time installations) Choose one: PN 23645-06, 15 ft cable with mating VP connector, prepped with BNC on analyzer end PN 23645-07, 15 ft cable with mating VP connector, prepped without BNC on analyzer end* 2. Retractable Mounting 1A.

Summary of the content on the page No. 10

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION SECTION 2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION. Inspect the outside The sensor must be mounted within 10-90 degrees of of the carton for any damage. If damage is detected, the horizontal with the tip pointed downward, thus contact the carrier immediately. Inspect the instrument keeping air bubbles off of the pH sensitive glass bulb. and hardware. Make sure all items in the packing list Bubbles settled on the glass bulb disrupt the electrical are

Summary of the content on the page No. 11

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION 6. While holding the sensor in position, tighten the hex 2.2.2 INSTALLATION WITHOUT A BALL VALVE. The nut of the male connector to firmly secure the sensor Model 396R Sensor may be installed through a weldalet in place. When the hex nut is tightened, the Teflon or pipe tee or “Y” when used with a process connector ferrule inside the compression fitting clamps the sen- (PN 23166-00 or 23166-01). The sensor should be sor tube. installed within 80° of

Summary of the content on the page No. 12

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION JUNCTION BOX IS OPTIONAL FIGURE 2-2. Typical Mounting Configurations for Model 396R FIGURE 2-3. Typical Mounting Configurations for Model 396RVP 8

Summary of the content on the page No. 13

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION INCH MILLIMETER FIGURE 2-4. Dimensional Drawing — Model 396R with Optional Ball Valve PN 23765-00 Note: Add five (5) inches to dimension A if mounting a sensor head junction box onto the sensor. 9

Summary of the content on the page No. 14

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG. NO. REV. 40396R05 D FIGURE 2-5. Dimensional Drawing — Model 396R with Optional Ball Valve PN 23240-00 Note: Add five (5) inches to dimension A if mounting a sensor head junction box onto the sensor. 10

Summary of the content on the page No. 15

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION MILLIMETER INCH 4.920 Front Side 396R-21 Note: Retraction Pressure 2.25 Back Side 396R Front Side 396R-25 Note: Retraction Pressure A MM / IN OPTION 548.64 / 21.60 21 916.94 / 36.10 25 FIGURE 2-6. Dimensional Warning Label for Model 396R Hemi Bulb Sensors and Sensor Diagram Note: Pressure rating for flat glass sensors is 100-790 kPa (0-100 psig). 11 36” 36”

Summary of the content on the page No. 16

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH FIGURE 2-7. Dimensional Drawing — Model 396RVP with Optional 1-1/2 inch Ball Valve PN 23240-00 12

Summary of the content on the page No. 17

MODEL 396R pH/ORP SECTION 2.0 INSTALLATION INCH MILLIMETER FIGURE 2-8. Dimensional Drawing — Model 396RVP with Optional 1-1/4 inch Ball Valve PN 23765-00 13

Summary of the content on the page No. 18

MODEL 396R pH/ORP SECTION 3.0 WIRING MODEL 396R SECTION 3.0 WIRING MODEL 396R WIRING MODEL 396R. 4. Signal cable should be run in a dedicated conduit Make electrical connections as shown on Figures 3-1 and should be kept away from AC power lines. through 3-15 using the following guidelines. For wiring Model 396RVP, see Section 4.0. NOTE 1. Pay particular attention to the analyzer or trans- For maximum EMI/RFI protection when wiring mitter model number when following details on the from the senso

Summary of the content on the page No. 19

MODEL 396R pH/ORP SECTION 3.0 WIRING MODEL 396R DWG. NO. REV. 40396R07 D FIGURE 3-2. Wiring Model 396R-54 to Models 54e, 81, 3081, 4081, and 5081 pH/ORP WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH MODELS 54e, 81, 3081, 4081, 5081 DWG. NO. REV. 40396R08 B FIGURE 3-3. Wiring Model 396R-54 with Remote J-Box and Preamp (PN 23555-00) 15

Summary of the content on the page No. 20

MODEL 396R pH/ORP SECTION 3.0 WIRING MODEL 396R DANGER: Do not connect sensor cable to power lines. Serious injury may result. PREP ORANGE WIRE FOR PREAMP 1 WITH BNC ADAPTER (PN 9120516). DWG. NO. REV. 40396R011 A FIGURE 3-4. Wiring Model 396R-50 for use with Remote Junction Box (PN 23309-03) DANGER: Do not connect sensor cable to power lines. Serious injury may result. PREP ORANGE WIRE FOR PREAMP 1 WITH BNC ADAPTER (PN 9120516). DWG. NO. REV. 40396R012 A FIGURE 3-5. Wiring Model 396R-54 for u


Alternative user manuals
# User manual Category Download
1 Emerson 142 User manual Stud Sensor 1
2 Emerson 396RVP User manual Stud Sensor 1
3 Emerson 228 User manual Stud Sensor 4
4 Emerson 396VP User manual Stud Sensor 0
5 Emerson 141 User manual Stud Sensor 0
6 Emerson 396 User manual Stud Sensor 0
7 Emerson 397 User manual Stud Sensor 0
8 Emerson 140 User manual Stud Sensor 0
9 Emerson 398 User manual Stud Sensor 0
10 Emerson CMF200A User manual Stud Sensor 25
11 Emerson 399VP User manual Stud Sensor 3
12 Emerson 398VP User manual Stud Sensor 0
13 Emerson 400 User manual Stud Sensor 6
14 Emerson 400 VP User manual Stud Sensor 4
15 Emerson Combination pH/ORP Sensor User manual Stud Sensor 0
16 A&D sf/sg User manual Stud Sensor 2
17 Sony ICX423AL User manual Stud Sensor 1
18 Sony E01X23A41 User manual Stud Sensor 1
19 Sony ICX418ALB User manual Stud Sensor 1
20 Agilent Technologies 81680A User manual Stud Sensor 3