Summary of the content on the page No. 2
WARRANTY The Anritsu product(s) listed on the title page is (are) warranted against defects in materials and workmanship for one year from the date of shipment. Anritsu's obligation covers repairing or replacing products which prove to be defec- tive during the warranty period. Buyers shall prepay transportation charges for equipment returned to Anritsu for warranty repairs. Obligation is limited to the origi- nal purchaser. Anritsu is not liable for consequential damages. LIMITATION OF WARRANTY
Summary of the content on the page No. 3
Summary of the content on the page No. 4
Table of Contents Chapter 1 - General Information Introduction..................................1-1 Description ..................................1-1 Standard Accessories.............................1-1 Options ....................................1-2 Optional Accessories .............................1-2 Performance Specifications .........................1-3 Preventive Maintenance ...........................1-6 Calibration ..................................1-6 InstaCal Module ...................
Summary of the content on the page No. 5
Setting the Scale................................3-7 Auto Scale......................................3-7 Amplitude Scale...................................3-7 Save and Recall a Setup ...........................3-7 Saving a Setup ...................................3-7 Recalling a Setup ..................................3-8 Save and Recall a Display ..........................3-8 Saving a Display ..................................3-8 Recalling a Display.................................3-8 Set the D
Summary of the content on the page No. 6
Chapter 7 - Site Master Software Tools Introduction..................................7-1 Features....................................7-1 System Requirements.............................7-1 Installation ..................................7-2 Communication Port Setting............................7-2 Interface Cable Installation ............................7-3 Using Software Tools.............................7-3 Downloading Traces from the Site Master .................7-3 Plot Capture...............
Summary of the content on the page No. 7
Summary of the content on the page No. 8
Chapter 1 General Information Introduction This chapter provides a description, performance specifications, optional accessories, pre- ventive maintenance, and calibration requirements for the Site Master models S113C, 1 S114C, S331C, and S332C. Throughout this manual, the term Site Master will refer to the models S113C, S114C, S331C, and S332C. Model Frequency Range S113C 2 to 1600 MHz S114C 2 to 1600 MHz, 100 kHz to 1600 MHz Spectrum Analysis S331C 25 to 4000 MHz S332C 25 to 4000 MHz, 100 kHz
Summary of the content on the page No. 9
Chapter 1 General Information The following items are supplied with the basic hardware. Soft Carrying Case AC-DC Adapter Automotive Cigarette Lighter 12 Volt DC Adapter, CDROM disk containing the Software Tools program. This program contains Fault Lo- cation (DTF) and Smith Chart functions Serial Interface Cable (null modem type) InstaCal Module One year Warranty (includes battery, firmware, and software) User's Guide Options Option 5 — Add Power Monitor Optional Accessories
Summary of the content on the page No. 10
Chapter 1 General Information Armored Test Port Extension Cable, 3.0 meter, N (m) to N (m), Part No. 15NN50-3.0C Armored Test Port Extension Cable, 5.0 meter, N (m) to N (m), Part No. 15NN50-5.0C Armored Test Port Extension Cable, 1.5 meter, N (m) to 7/16 DIN (f), Part No. 15NDF50-1.5C Armored Test Port Extension Cable, 1.5 meter, N (m) to 7/16 DIN (m), Part No. 15ND50-1.5C RF Detector, 1 to 3000 MHz, N(m) input connector, 50 Ohms, Part No. 5400-71N50 RF Detector, 0.01 to 20 GHz, N(m
Summary of the content on the page No. 11
Chapter 1 General Information Table 1-1. Performance Specifications (1 of 2) Specifications are valid when the unit is calibrated at ambient temperature after a 5 minute warmup. Typical values are provided for reference only and are not guaranteed. Description Value Site Master: Frequency Range: S113C, S114C 2 to 1600 MHz S331C, S332C 25 to 4000 MHz Frequency Accuracy (RF Source Mode) 75 parts per million @ 25°C* Frequency Resolution: S113C, S114C 10 kHz S331C, S332C 100 kHz SWR: Range 1.00 to
Summary of the content on the page No. 12
Chapter 1 General Information Table 1-2. Performance Specifications (2 of 2) Spectrum Analyzer: Frequency Range S114C 100 kHz to 1.6 GHz S332C 100 kHz to 3.0 GHz Frequency Reference Aging ±1 ppm/yr Accuracy ±2 ppm Frequency Span S114C 0 Hz (zero span) 100 kHz to 1.6 GHz S332C 0 Hz (zero span) 100 kHz to 3.0 GHz Sweep Time 650 ms (full span) 500 ms (zero span) Resolution Bandwidth 10 kHz, 30 kHz, 100 kHz, 1 MHz Accuracy ± 20% typical Video Bandwidth 100 Hz to 300 kHz in 1-3 sequence SSB Phase No
Summary of the content on the page No. 13
Chapter 1 General Information Preventive Maintenance Site Master preventive maintenance consists of cleaning the unit and inspecting and clean- ing the RF connectors on the instrument and all accessories. Clean the Site Master with a soft, lint-free cloth dampened with water or water and a mild cleaning solution. CAUTION: To avoid damaging the display or case, do not use solvents or abra- sive cleaners. Clean the RF connectors and center pins with a cotton swab dampened with denatured alco- hol.
Summary of the content on the page No. 14
Chapter 1 General Information InstaCal Module The Anritsu InstaCal module can be used in place of discrete components to calibrate the Site Master. The InstaCal module can be used to perform an Open, Short and Load (OSL) calibration procedure. Calibration of the Site Master with the InstaCal takes approximately 45 seconds (see Calibration, page 3-2). Unlike a discrete calibration component, the InstaCal module can not be used at the top of the tower to conduct load or insertion loss measurements
Summary of the content on the page No. 15
Chapter 1 General Information Table 1-2. Anritsu Service Centers UNITED STATES CHINA KOREA ANRITSU COMPANY ANRITSU (SHANGHAI) ACSH ANRITSU CORPORATION LTD. 685 Jarvis Drive 2F, Rm. B, 52 Section Factory Building #901 Daeo Bldg. 26-5 Morgan Hill, CA 95037-2809 No. 516 Fu Te Road (N) Yeoido Dong, Youngdeungpo Telephone: (408) 776-8300, Waigaoqiao Free Trade Zone Seoul Korea 150 010 1-800-ANRITSU Pudong, Shanghai 200131 Telephone: 02-782-7156 FAX: 408-776-1744 Telephone: 021-5868-0226 FAX: 02-782-4
Summary of the content on the page No. 16
Chapter 2 Functions and Operations Introduction This chapter provides a brief overview of the Site Master functions and operations, provid- ing the user with a starting point for making basic measurements. For more detailed infor- mation, refer to Chapter 4, Measurements and Chapter 7, Software Tools. The Site Master is designed specifically for field environments and applications requiring mobility. As such, it is a lightweight, handheld, battery operated unit which can be easily carried to any
Summary of the content on the page No. 17
Chapter 2 Functions and Operations Front Panel Overview The Site Master menu-driven user interface is easy to use and requires little training. Hard keys on the front panel are used to initiate function-specific menus. There are four function hard keys located below the display, Mode, Frequency/Distance, Amplitude and Sweep. There are seventeen keypad hard keys located to the right of the display. Twelve of the key- pad hard keys perform more than one function, depending on the current mode of o
Summary of the content on the page No. 18
Chapter 2 Functions and Operations Function Hard Keys MODE Opens the mode selection box (below). Use the Up/Down arrow key to select a mode. Press the ENTER key to implement. MEASUREMENT MODE FREQ - SWR RETURN LOSS CABLE LOSS - ONE PORT DTF - SWR RETURN LOSS POWER MONITOR SPECTRUM ANALYZER Figure 2-2. Mode Selection Box FREQ/DIST Displays the Frequency or Distance to Fault softkey menus depending on the measurement mode. AMPLITUDE Displays the amplitude softkey menu for the current operating mod
Summary of the content on the page No. 19
Chapter 2 Functions and Operations Keypad Hard Keys This section contains an alphabetical listing of the Site Master front panel keypad controls along with a brief description of each. More detailed descriptions of the major function keys follow. The following keypad hard key functions are printed in black on the keypad keys. 0-9 These keys are used to enter numerical data as required to setup or per- form measurements. The plus/minus key is used to enter positive or negative values as required
Summary of the content on the page No. 20
Chapter 2 Functions and Operations The following keypad hard key functions are printed in blue on the keypad keys. Turns the liquid crystal display (LCD) back-lighting ON or OFF. (Leaving back lighting off conserves battery power.) LCD Contrast adjust. Use the Up/Down arrow key and ENTER to adjust the display contrast. AUTO Automatically scales the display for optimum resolution. SCALE LIMIT Displays the limit line menu for the current operating mode. MARKER Displays the marker menu of the curre