Summary of the content on the page No. 1
®
4
CS 800x
Power Amplifier Owner's Manual
For more information on other great Peavey products, visit your local Peavey dealer or go online to www.peavey.com
Summary of the content on the page No. 2
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts insi
Summary of the content on the page No. 3
IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electrical products, basic cautions should always be followed, including the following: 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers
Summary of the content on the page No. 4
WICHTIGE SICHERHEITSHINWEISE ACHTUNG: Beim Einsatz von Elektrogeräten müssen u.a. grundlegende Vorsichtsmaßnahmen befolgt werden: 1. Lesen Sie sich diese Anweisungen durch. 2. Bewahren Sie diese Anweisungen auf. 3. Beachten Sie alle Warnungen. 4. Befolgen Sie alle Anweisungen. 5. Setzen Sie dieses Gerät nicht in der Nähe von Wasser ein. 6. Reinigen Sie es nur mit einem trockenen Tuch. 7. Blockieren Sie keine der Lüftungsöffnungen. Führen Sie die Installation gemäß den Anweisungen des Herstelle
Summary of the content on the page No. 5
INSTRUCTIONS IMPORTANTES DE SECURITE ATTENTION: L’utilisation de tout appareil électrique doit être soumise aux precautions d’usage incluant: 1. Lire ces instructions. 2. Gardez ce manuel pour de futures références. 3. Prétez attention aux messages de précautions de ce manuel. 4. Suivez ces instructions. 5. N’utilisez pas cette unité proche de plans d’eau. 6. N’utilisez qu’un tissu sec pour le nettoyage de votre unité. 7. N’obstruez pas les systèmes de refroidissement de votre unité et instal
Summary of the content on the page No. 6
INSTRUCCIONES IMPORTANTES PARA SU SEGURIDAD CUIDADO: Cuando use productos electrónicos, debe tomar precauciones básicas, incluyendo las siguientes: 1. Lea estas instrucciones. 2. Guarde estas instrucciones. 3. Haga caso de todos los consejos. 4. Siga todas las instrucciones. 5. No usar este aparato cerca del agua. 6. Limpiar solamente con una tela seca. 7. No bloquear ninguna de las salidas de ventilación. Instalar de acuerdo a las instrucciones del fabricante. 8. No instalar cerca de ninguna fu
Summary of the content on the page No. 7
ENGLISH ® 4 CS 800x Power Amplifier Congratulations on your purchase of a Peavey CS Series power amplifier! Designed for years of reliable operation, CS Series amplifiers offer the sonic superiority and unsurpassed reliability for which Peavey is famous in a rugged, compact unit. Advanced technologies and extensive protection circuitry allow operation with greater efficiency, even under difficult loads ™ and power conditions. The DDT (Distortion Detection Technique) circuit ensures trouble-f
Summary of the content on the page No. 8
Introduction Operating Precautions Make sure the mains voltage is correct and the same as that printed on the rear of the amplifier. Damage caused by ® connecting the amplifier to improper AC voltage is not covered by any CS Series warranty. See the Connecting Power section for more information on voltage requirements. Note: Always turn off and disconnect the amplifier from mains voltage before making audio connections. Also, as an extra precaution, have the attenuators turned down during pow
Summary of the content on the page No. 9
Wire Gauge Charts Stranded Cable Lgth. Wire Gauge (AWG) Power Loss Power Loss Power Loss (ft.) (8 ohm load) (4 ohm load) (2 ohm load) 5 18 0.81% 1.61% 3.2% 16 0.51 1.02 2.0 14 0.32 0.64 1.28 12 0.20 0.40 0.80 10 0.128 0.25 0.51 10 18 1.61% 3.2% 6.2% 16 1.02 2.0 4.0 14 0.64 1.28 2.5 12 0.40 0.80 1.60 10 0.25 0.51 1.01 40 18 6.2% 11.9% 22% 16 4.0 7.7 14.6 14 2.5 5.0 9.6 12 1.60 3.2 6.2 10 1.01 2.0 4.0 8 0.60 1.20 2.4 18 11.9% 22% 37% 80 16 7.7 14.6 26 14 5.0 9.6 17.8 12 3.2 6.2 11.8 10 2.0 4.0 7.7
Summary of the content on the page No. 10
Operation Modes Stereo Operation For stereo (dual channel) operation, turn the amplifier OFF and set the mode select switches to the stereo position. In this mode, the respective channels operate independently of each other, with their input attenuators controlling their respective levels. Thus, a signal at channel 1's input produces an amplified signal at channel 1's output, while a signal at channel 2's input produces an amplified signal at channel 2's output. The same applies to channels 3
Summary of the content on the page No. 11
Front Panel 2 2 Rear Panel 1 3 Switches & Controls AC Power Circuit Breakers (1) ® 4 The CS 800x amplifier has two circuit breakers on the back panel. If circuit breaker shuts off during normal use, push it back to the ON position once. If it will not stay ON, the amplifier needs servicing. Input Attenuators (2) Whenever possible, set the attenuators fully clockwise to maintain optimum system headroom. The four input attenuator controls located at the front panel decrease gain (signal le
Summary of the content on the page No. 12
Front Panel 1 1 3 3 2 2 2 2 1 1 3 3 Indicators ® ™ CS Series amplifiers feature three front panel LED indicators per channel: PWR (power), SIG (signal), and DDT (Distortion Detection Technique). These LED indicators inform the user of each channel’s operating status and warn of possible abnormal conditions. PWR LED (1) The Power LED indicates that its channel’s output relay is closed and the channel is operational. SIG LED (2) The Signal LED illuminates when its channel produces an output sign
Summary of the content on the page No. 13
Protection Features ® 4 The CS 800x amplifier incorporates several circuits to protect both itself and loudspeakers under virtually any situation. Peavey has made this amplifier as foolproof as possible by making it immune to short and open circuits, mismatched loads, DC voltage and overheating. If a channel goes into the DDT™ gain reduction mode, the DDT LED illuminates. The speaker load remains connected, but clipping percentage or output power is instantly reduced. When a problem occurs t
Summary of the content on the page No. 14
Protection Features ™ RampUp Signal Control ® 4 Whenever the CS 800x amplifier powers up or comes out of a protect mode, the RampUp circuit activates. While the speakers are disconnected, the RampUp circuit fully attenuates the signal and activates the DDT LED. After the output relay closes, the signal slowly and gradually raises to its set level. The PWR LED will illuminate and the DDT LED will turn off when the signal is no longer attenuated. The RampUp Signal Control circuit has some impor
Summary of the content on the page No. 15
Amplifier Maintenance and User Responsiblity ® 4 The CS 800x amplifier requires no routine maintenance and should not need internal adjustment during its lifetime. Your CS 800x4 amplifier is very powerful and can be potentially dangerous to loudspeakers and humans alike. It is your responsibil- ity to read the Important Precautions section and to make sure that the amplifier is installed, wired and operated properly as instructed in this manual. Many loudspeakers can be easily damaged or destroy
Summary of the content on the page No. 16
® CS 800x4 Power Amplifier SPECIFICATIONS CS 800x4 825 watts @ 1 kHz <0.025% THD Rated Power 4 ohms bridged 400 watts per channel @ 1 kHz <0.025% THD four channels driven Rated Power 4 x 2 ohms 300 watts per channel @ 1 kHz <0.02% THD four channels driven Rated Power 4 x 4 ohms 180 watts per channel @ 1 kHz <0.02% THD four channels driven Rated Power 4 x 8 ohms 500 watts @ 1 kHz at <0.02% THD Rated Power 1 x 2 ohms 350 watts @ 1 kHz at <0.015% THD Rated Power 1 x 4 ohms 200 watts @ 1 kH
Summary of the content on the page No. 17
® CS 800x4 Power Amplifier SPECIFICATIONS CS 800x4 > -60 dB, “A” weighted referenced to rated 4 ohms power Crosstalk 930 watts @ 2 ohms, 640 watts @ 4 ohms, 420 watts @ 8 ohms Current Draw @ 1/8 Power 1995 watts @ 2 ohms, 1365 watts @ 4 ohms, 795 watts @ 8 ohms Current Draw @ 1/3 Power 60 watts Idle Current Draw 80 mm DC fan, off until heat sink reaches 45° C, then variable speed Cooling 4 attenuators, 2 mode select switches Controls 4 DDT™, 4 Power/Status, 4 Signal Present Indicator LED
Summary of the content on the page No. 18
DEUTSCH ® 4 CS 800x Endstufe Herzlichen Glückwunsch zum Kauf einer Endstufe der CS Series von Peavey! Die Verstärker der CS Series wurden für einen zuverlässigen Betrieb und lange Lebensdauer entwickelt. In einem robusten, kompakten Gerät bieten sie die überragende Schallleistung und die unübertroffene Zuverlässigkeit, für die Peavey bekannt ist. Fortschrittliche Technologien und umfassende Schutzschaltungen ermöglichen einen effizienteren Betrieb auch bei problematischen Lasten und ™ Energ
Summary of the content on the page No. 19
Einleitung Sicherheitshinweise für den Betrieb Achten Sie darauf, dass die Netzspannung korrekt ist und mit den Angaben auf der Rückseite des Verstärkers übereinstimmt. Schäden, die aufgrund des Anschlusses des Verstärkers an eine ungeeignete Wechselspannung ® entstehen, werden nicht von der CS -Series-Garantie abgedeckt. Nähere Informationen zur erforderlichen Spannung finden Sie im Abschnitt Netzanschluss. Hinweis: Schalten Sie den Verstärker immer aus und trennen Sie ihn vom Netz, bevor Si
Summary of the content on the page No. 20
Kabelstärkentabellen Stranded Cable Lgth. Wire Gauge (AWG) Power Loss Power Loss Power Loss (ft.) (8 ohm load) (4 ohm load) (2 ohm load) 5 18 0.81% 1.61% 3.2% 16 0.51 1.02 2.0 14 0.32 0.64 1.28 12 0.20 0.40 0.80 10 0.128 0.25 0.51 10 18 1.61% 3.2% 6.2% 16 1.02 2.0 4.0 14 0.64 1.28 2.5 12 0.40 0.80 1.60 10 0.25 0.51 1.01 40 18 6.2% 11.9% 22% 16 4.0 7.7 14.6 14 2.5 5.0 9.6 12 1.60 3.2 6.2 10 1.01 2.0 4.0 8 0.60 1.20 2.4 18 11.9% 22% 37% 80 16 7.7 14.6 26 14 5.0 9.6 17.8 12 3.2 6.2 11.8 10 2.0 4.0