Peavey CS 4000 user manual

User manual for the device Peavey CS 4000

Device: Peavey CS 4000
Category: Stereo Amplifier
Manufacturer: Peavey
Size: 13.39 MB
Added : 10/2/2013
Number of pages: 52
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Peavey CS 4000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Peavey CS 4000.

For your convenience

If looking through the Peavey CS 4000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Peavey CS 4000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Peavey CS 4000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Peavey CS 4000 User manual - Online PDF
Advertisement
« Page 1 of 52 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Peavey CS 4000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Peavey CS 4000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
3 4 4
CS 000/ 000/ 080 HZ
Power Amplifier Owner's Manual
For more information on other great Peavey products, visit your local Peavey dealer or go online to www.peavey.com

Summary of the content on the page No. 2

Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts insi

Summary of the content on the page No. 3

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Summary of the content on the page No. 6

Summary of the content on the page No. 7

ENGLISH ® 3 4 4 CS 000/ 000/ 080 HZ Power Amplifiers Congratulations on your purchase of a Peavey CS Series power amplifier! Designed for years of reliable operation, CS Series amplifiers offer the sonic superiority and unsurpassed reliability for which Peavey is famous in a rugged, compact unit. Advanced technologies and extensive protection circuitry allow operation with greater efficiency, even under difficult loads ™ and power conditions. The DDT (Distortion Detection Technique) circuit

Summary of the content on the page No. 8

Summary of the content on the page No. 9

Wire Guage Charts Stranded Cable Lgth. Wire Gauge (AWG) Power Loss Power Loss Power Loss (ft.) (8 ohm load) (4 ohm load) (2 ohm load) 5 18 0.81% 1.61% 3.2% 16 0.51 1.02 2.0 14 0.32 0.64 1.28 12 0.20 0.40 0.80 10 0.128 0.25 0.51 10 18 1.61% 3.2% 6.2% 16 1.02 2.0 4.0 14 0.64 1.28 2.5 12 0.40 0.80 1.60 10 0.25 0.51 1.01 40 18 6.2% 11.9% 22% 16 4.0 7.7 14.6 14 2.5 5.0 9.6 12 1.60 3.2 6.2 10 1.01 2.0 4.0 8 0.60 1.20 2.4 18 11.9% 22% 37% 80 16 7.7 14.6 26 14 5.0 9.6 17.8 12 3.2 6.2 11.8 10 2.0 4.0 7.7

Summary of the content on the page No. 10

Operation Modes Stereo Operation For stereo (dual channel) operation, turn the amplifier OFF and set the mode select switches on the back panel to the out (extended) position. In this mode, both channels operate independently of each other, with their input attenuators controlling their respective levels. Thus, a signal at channel A’s input produces an amplified signal at channel A’s output, while a signal at channel B’s input produces an amplified signal at channel B’s output. Parallel Oper

Summary of the content on the page No. 11

CAUTION: The on/off switch in this unit does not break both sides of the primary mains. Hazardous energy can be present inside the chassis when the on/off switch is in the off position.

Summary of the content on the page No. 12

Front Panel 3 1 1 3 2 2 Indicators ® ™ CS Series amplifiers feature three front panel LED indicators per channel: PWR (power), SIG (signal) and DDT (Distortion Detection Technique). These LED indicators inform the user of each channel’s operating status and warn of possible abnormal conditions. PWR LED (1) The Power LED indicates that the channel is operational. It illuminates under normal operation and remains on even when the channel’s DDT circuit is activated. SIG LED (2) The Signal LED il

Summary of the content on the page No. 13

Protection Features ® The Peavey CS Series incorporates several circuits to protect the amplifier and speakers under virtually any situation. Peavey has made the amplifiers as foolproof as possible by making them immune to short and open circuits, mismatched loads, ™ DC voltage and overheating. If a channel goes into the DDT gain reduction mode, the DDT LED illuminates. The clipping percentage or output power is instantly reduced. When a problem occurs that causes a channel to go into a prote

Summary of the content on the page No. 14

Protection Features ™ RampUp Signal Control ® Whenever a CS Series amplifier powers up or comes out of a protect mode, the RampUp circuit activates. While the ™ speakers are disconnected, the RampUp circuit fully attenuates the signal and activates the DDT LED. After the output relay closes, the signal slowly and gradually raises up to its set level. The PWR LED will illuminate and the DDT LED will turn off when the signal is no longer attenuated. The RampUp Signal Control circuit has some i

Summary of the content on the page No. 15

Amplifier Maintenance and User Responsibility A CS Series amplifier requires no routine maintenance and should not need internal adjustment during its lifetime. Your CS Series amplifier is very powerful and can be potentially dangerous to loudspeakers and humans alike. It is your responsibil- ity to read the Important Precautions section and to make sure that the amplifier is installed, wired and operated properly as instructed in this manual. Many loudspeakers can be easily damaged or destroyed

Summary of the content on the page No. 16

® CS Series 3000/4000/4080 HZ Power Amplifiers SPECIFICATIONS CS 3000 CS 4000 CS 4080 HZ 3,050 watts @ 1 kHz at 4,000 watts @ 1 kHz at 4,080 watts @ 1 kHz at Rated Power Bridged <0.1% T.H.D. @ 4 ohms <0.1% T.H.D. @ 4 ohms <0.1% T.H.D. @ 8 ohms 1,500 watts per channel 2,000 watts per channel N/A Rated Power 2 x 2 ohms @ 1 kHz <0.05% T.H.D. @ 1 kHz <0.1% T.H.D. both channels driven both channels driven 1,025 watts per channel 1,350 watts per channel 2,040 watts per channel Rated Power 2 x

Summary of the content on the page No. 17

® CS Series SPECIFICATIONS CS 3000 CS 4000 CS 4080 HZ > 15V/us > 15V/us > 15V/us Slew Rate > 500:1 @ 20 Hz - 1 > 500:1 @ 20 Hz - 1 > 500:1 @ 20 Hz - 1 Damping Factor (8 ohms) kHz kHz kHz +5 to - 15 degrees from +5 to - 12 degrees from +5 to - 12 degrees from Phase Response 20 Hz to 20kHz 20 Hz to 20kHz 20 Hz to 20kHz 1.6 volts +/- 3% for 1 1.84 volts +/- 3% for 1 2.25 volts +/- 3% for 1 Input Sensitivity kHz. 4 ohms rated power, kHz. 4 ohms rated power, kHz. 4 ohms rated power 1.37 volts

Summary of the content on the page No. 18

DEUTSCH ® 3 4 4 CS 000/ 000/ 080 HZ Endstufen Herzlichen Glückwunsch zum Kauf einer Endstufe der CS Series von Peavey! Die Verstärker der CS Series wurden für einen zuverlässigen Betrieb und lange Lebensdauer entwickelt. In einem robusten, kompakten Gerät bieten sie die überragende Schallleistung und die unübertroffene Zuverlässigkeit, für die Peavey bekannt ist. Fortschrittliche Technologien und umfassende Schutzschaltungen ermöglichen einen effizienteren Betrieb auch bei problematischen L

Summary of the content on the page No. 19

Summary of the content on the page No. 20

Kabelstärkentabellen Stranded Cable Lgth. Wire Gauge (AWG) Power Loss Power Loss Power Loss (ft.) (8 ohm load) (4 ohm load) (2 ohm load) 5 18 0.81% 1.61% 3.2% 16 0.51 1.02 2.0 14 0.32 0.64 1.28 12 0.20 0.40 0.80 10 0.128 0.25 0.51 10 18 1.61% 3.2% 6.2% 16 1.02 2.0 4.0 14 0.64 1.28 2.5 12 0.40 0.80 1.60 10 0.25 0.51 1.01 40 18 6.2% 11.9% 22% 16 4.0 7.7 14.6 14 2.5 5.0 9.6 12 1.60 3.2 6.2 10 1.01 2.0 4.0 8 0.60 1.20 2.4 18 11.9% 22% 37% 80 16 7.7 14.6 26 14 5.0 9.6 17.8 12 3.2 6.2 11.8 10 2.0 4.0


Alternative user manuals
# User manual Category Download
1 Peavey 12/0280304941 User manual Stereo Amplifier 8
2 Peavey 158, 110, 112, 115 User manual Stereo Amplifier 54
3 Peavey 2.6 C User manual Stereo Amplifier 18
4 Peavey 50 212 User manual Stereo Amplifier 42
5 Peavey 2000 User manual Stereo Amplifier 166
6 Peavey 646-049 User manual Stereo Amplifier 2
7 Peavey 50 410 User manual Stereo Amplifier 13
8 Peavey 1400 User manual Stereo Amplifier 3
9 Peavey 300 Series User manual Stereo Amplifier 32
10 Peavey 8002 User manual Stereo Amplifier 5
11 Peavey 650-004 User manual Stereo Amplifier 2
12 Peavey 646-063 User manual Stereo Amplifier 1
13 Peavey 6505TM User manual Stereo Amplifier 4
14 Peavey 80304543 User manual Stereo Amplifier 1
15 Peavey Artist V T Series User manual Stereo Amplifier 4
16 Sony SA-VE312 User manual Stereo Amplifier 9
17 Sony MONAURAL User manual Stereo Amplifier 1
18 Sony 4-151-113-11 (1) User manual Stereo Amplifier 0
19 Sony 645-139 User manual Stereo Amplifier 3
20 Sony XM-1252GTR User manual Stereo Amplifier 35