Fostex AP1020 user manual

User manual for the device Fostex AP1020

Device: Fostex AP1020
Category: Stereo Amplifier
Manufacturer: Fostex
Size: 0.26 MB
Added : 1/14/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fostex AP1020. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fostex AP1020.

For your convenience

If looking through the Fostex AP1020 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fostex AP1020 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fostex AP1020 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fostex AP1020 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fostex AP1020 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fostex AP1020. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual
Model
AP1020/AP2090/AP2130
STEREO POWER AMPLIFIER

Summary of the content on the page No. 2

CAUTION: CAUTION TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENTION: POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, FICHE DANS LA BORNE CORRESPONDANTE DE DO NOT REMOVE COVER (OR BACK). LA PRISE ET POUSSER JUSQU AU FOND. NO USER - SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lighting flash with arrowhead symbol, w

Summary of the content on the page No. 3

INTRODUCTION Fostex new AP Series amplifiers AP1020, AP1020, AP2090 and AP2130 are designed to withstand severe operating conditions. It is a commercial use amplifier containing high technology citcuits designed for stability, durability, small size and large output. Contents Controls and connections (Model AP2090/AP2130)..................................2 Controls and Connections (Model AP1020)..............................................3 Outstanding features.....................

Summary of the content on the page No. 4

AP2090/AP2130 FRONT PANEL REAR PANEL 10. Input connector 1. Power switch 11. Crossover mode (VR) 2. Power indicator 12. Crossover mode (Selector) 3. Output level controller 13. MONO/STEREP selector SW 4. Output level indicator 14. Crossover network output 5. Clip indicator (HIGH) 6. Thermal indicator 15. Crossover network output 7. Compressor / limiter indicator (LOW) 8. Handle 16. COMP/L switch 9. Filter cover 17. Speaker output 18. Cooling fa

Summary of the content on the page No. 5

AP1020 FRONT PANEL REAR PANEL 1. Power switch 10. AC (Input) 2. Power indicator 11. MONO/STEREO switch 3. Output level controller 12. Fuse 4. Output level indicator 13. Cooling fan 5. Clip indicator 14. Compressor / limiter switch 6. Thermal indicator 15. Input connector 7. Compressor / limiter indicator 16. Output connector CH-1 8. Handle 17. " " CH-2 9. Filter cover —3—

Summary of the content on the page No. 6

OUTSTANDING FEATURES 1) Forced cooling When the amplifier internal temperature rises, thee cooling fan automatically changes to high speed to force cool the heat sink for protecting the amplifier. 2) Level indicator (AP2090, AP2130) This LED is lit in 5dB steps over the 0 ~ - 30dB range to check the input signal. 3) Clip indicator This LED is lit at overload. It will flash on large instant- aneous inputs but will not pose any problems. 4) Thermal indicator

Summary of the content on the page No. 7

CROSSOVER NETWORK, SELECTOR SWITCH 1) FULL At this position, the crossover network is bypassed, (Hz) control pot becomes ineffective, a flat response output against the input signal is obtained at the output connec- tor. The crossover network outputs (HIGH, LOW) at each con- nector will be those set by the crossover frequency adjust- inig knobs. 2) HIGH When this position is selected, the HIGH PASS signal whose cutoff frequency is set by the (Hz) knob, i

Summary of the content on the page No. 8

MULTI-AMPLIFIER SYSTEM EXAMPLE USUNG AP2090/2130 [Example of 2 way system] AMP (HIGH P 1 ASS AMP) INPUT FULL INPUT H.SP HIGH H LOW L HIGH OUT LOW OUT 2 AMP (LOW PASS AMP) INPUT FULL L.SP HIGH H LOW L HIGH OUT LOW OUT [Example of 3 way system] AMP (HIGH P 1 ASS AMP) INPUT FULL H.SP HIGH H LOW L HIGH OUT LOW OUT AMP (BAND P 2 ASS AMP) INPUT FULL M.SP HIGH H LOW L HIGH OUT LOW OUT 3 AMP (LOW PASS AMP) FULL INPUT L.SP HIGH H LOW L HIGH OUT LOW OUT —6—

Summary of the content on the page No. 9

* General use amplifiers not containing a crossover network can also be used for the low region or high region amplifier. When Ap20909/2130 are to be used as a full range amplifier, harmful sub-sonic frequencies can be cut off if the crossover network selector switch is set to HIGH and crossover frequency to 30Hz. If a line transformer is to be connected, always set to HIGH PASS (crossover network selector switch to HIGH) and crossover frequency to 100Hz. The speaker low regio

Summary of the content on the page No. 10

SPECIFICATIONS AP1020 AP2090 AP2130 [AMPLIFIER SECTION] 75W+75W. . . . 8 Ω 300W+300W. . . 8 Ω 450W+450W. . . 8 Ω 100W+100W. . . 8 Ω 450W+450W. . . 4 Ω 650W+650W. . . 4 Ω Rated output 200W(mono). . . 8 Ω 900W(mono). . . 8 Ω 1300W(mono). . 8 Ω Total harmonic Less than Less than Less than distortion 0.05% 0.05% 0.05% (At 1kHz rated output) 10 ~ 35,000Hz 10 ~ 35,000Hz 10 ~ 35,000Hz Reproduce (At rated out- (At rated out- (At rated out- frequnecy put, +0dB, put, +0dB, put, +0dB, range -1dB) -1dB) -


Alternative user manuals
# User manual Category Download
1 Fostex 24-bit A/D Converter AC2496 User manual Stereo Amplifier 0
2 Fostex 5030 User manual Stereo Amplifier 17
3 Fostex AP3060 User manual Stereo Amplifier 9
4 Fostex AP2130 User manual Stereo Amplifier 8
5 Fostex AP3090 User manual Stereo Amplifier 4
6 Fostex CR500 User manual Stereo Amplifier 60
7 Fostex UR-2 User manual Stereo Amplifier 10
8 Fostex AP2090 User manual Stereo Amplifier 8
9 Fostex PH-100 User manual Stereo Amplifier 4
10 Sony SA-VE312 User manual Stereo Amplifier 9
11 Sony MONAURAL User manual Stereo Amplifier 1
12 Sony 4-151-113-11 (1) User manual Stereo Amplifier 0
13 Sony 645-139 User manual Stereo Amplifier 3
14 Sony XM-1252GTR User manual Stereo Amplifier 35
15 Sony DMX-R100 User manual Stereo Amplifier 210