Toro TMC-424E user manual

User manual for the device Toro TMC-424E

Device: Toro TMC-424E
Category: Sprinkler
Manufacturer: Toro
Size: 3.89 MB
Added : 2/19/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Toro TMC-424E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Toro TMC-424E.

For your convenience

If looking through the Toro TMC-424E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Toro TMC-424E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Toro TMC-424E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Toro TMC-424E User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Toro TMC-424E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Toro TMC-424E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

English Español Français
TMC-424E TMC-424E Quick Reference Guide Quick Reference Guide
Adjust Time/Date .................................. 2
Set Season Adjust % Factor................ 2
ON
PREV NEXT
Set Rain Delay....................................... 3
OFF
Manual Station Operations.................. 3
Manual Program Operations ............... 5
Set Station Run Time ........................... 6
Set Program Start Time........................ 7
Set Watering Day Schedule................. 8
%
Re

Summary of the content on the page No. 2

Adjust Time/Date Set Season Adjust % Factor 1. Turn the Function Dial to 1. Set the Program Switch to select Current Time/Day . The hour program A, B, C, or D. digits will begin flashing. 2. Turn Function Dial to Season Adjust . 2. Adjust the display by pressing the 3. Press the or button to adjust the or button. % value for the selected program. NOTE: Hold either button down for NOTE: Adjusting the % value to Off rapid advance. prevents operation of the program. 3. Press the button to sele

Summary of the content on the page No. 3

NOTE: Adjusting the % value to Off Set Rain Delay prevents operation of all programs for the entire month. 1. Turn the Function Dial to OFF . NOTE: The % symbol will be displayed 2. Press the or button to select the to indicate when a Season Adjust % number of days to delay operation from factor is applied. 1 to 14. 3. Turn the Function Dial to RUN . NOTE: OFF and the number of rain delay days remaining until automatic operation resumes will be displayed. Automatic operation will resume when

Summary of the content on the page No. 4

Timed Manual Operation Manual Station Operations 1. Turn Function Dial to Manual Stations . 2. Press the button to select the station IMPORTANT: True Manual operation number. will override all flow-sensing limits.True Manual Operation 3. Press the or button to select a manual run time (1 minute – 8 hours). 1. Turn Function Dial to Manual Stations . 4. To select additional stations, repeat 2. Press the button as needed to select steps 2 and 3. the station number. 5. When station selections have

Summary of the content on the page No. 5

• Automatic mode will resume when the 3. Press the button to start the watering manual operation has been completed. cycle. The first station in sequence will • To advance through the station turn on. The program identifier and icon sequence, press the button. will begin flashing. • To terminate manual operation at any 4. Turn the Function Dial to RUN . time, turn the Function Dial to OFF . • The operating station number, remain- When the display stops flashing, return ing station run time and

Summary of the content on the page No. 6

• Multiple Program Operation • Automatic mode will resume when the manual operation is finished. 1. Turn Function Dial to • To turn off an active station and start Manual Programs . the next station in sequence, position 2. Set the Program Switch to select pro- Program Switch (if needed) to select gram A, B, C, or D. the program, then press the button. 3. Press the button to start the program • To end manual operation at any time, watering cycle. The program identifier . turn the Function Di

Summary of the content on the page No. 7

NOTE: Any start time number currently 4. Press the or button to adjust assigned to another program can not be the station run time from Off (-- -- --)to selected. If all 16 start time assignments 8 hours (in 1-minute increments). are in use, NONE will be displayed. If seconds format is enabled, station run 4. Press the or button to select a start time can be set from 01–60 seconds. time hour (note the correct a.m./p.m. NOTE: Hold either button down for designation in the 12-hour clock mode).

Summary of the content on the page No. 8

To Set Odd or Even Days: Set Watering Day Schedule 1. Set the Program Switch to select program A, B, C, or D. Note: If the program has an Interval or 2. Turn the Function Dial to the Odd/Even schedule currently set, it must Odd/Even position. be removed first to select another format. 3. Press the or button to select To Set Calendar Days: ODD or EVEN. 1. Set the Program Switch to select program A, B, C, or D. 4. To exclude specific days from watering, press the button to select the day. 2. Tu

Summary of the content on the page No. 9

For example, if a 04 DAY Interval is To Set Interval Days: entered and watering is to begin in one 1. Set the Program Switch to select day, select 03 as the Current Day. program A, B, C, or D. 5. To select the Current Day in the Interval 2. Turn the Function Dial to the Interval cycle, press the button to display the Days position. CURRENT DAY prompt. 3. The CYCLE LENGTH prompt and the 6. Press the or button to select the current Interval (01–31DAY or -- -- -- [Off]) value (01–selected Interv

Summary of the content on the page No. 10

1. Turn the Function Dial to Review . Review Program Settings 2. Set the Program Switch to select the program to be reviewed. The Program Review feature provides a 3. Press the button to index through convenient method of reviewing all the program information. user-defined programming information. 4. When finished, turn the Function Dial Program elements are displayed as follows: to RUN . • Total program cycle duration, factored for Season Adjust %, delays and repeats. • Total irrigation time

Summary of the content on the page No. 11

IMPORTANT: Clearing the display Alert Displays does not correct the problem. The controller will retry the affected FUSE – Station and MV/PS output alarm station(s) at each programmed watering The TMC-424E features built-in circuit cycle and bypass the affected station(s) protection to help prevent damage to the until the problem is corrected. controller caused by an over-current Before continuing to operate the condition on any output terminal. If the controller, identify and correct the contro

Summary of the content on the page No. 12

FLOW or NFLOW – Flow sensor alarms SEN – Rain sensor active When flow monitoring is used, the FLOW When the rain sensor is active and all error message will be displayed when a controller outputs are off, the SEN prompt station experiences an over-, under-, or is displayed. Rain sensor input can be critical-flow error. In this event, the station bypassed with the controller’s Sensor is skipped, and the next programmed Bypass switch, the Timed Bypass feature station in sequence is operated. and r

Summary of the content on the page No. 13

Español TMC-424E Manual de consulta rápida TMC-424E Manual de consulta rápida Ajuste de hora/fecha ....................................... 2 Ajuste del factor % de Ajuste de temporada ........... 2 ON PREV NEXT Ajuste del Retardo de lluvia .............................. 3 OFF Funcionamiento manual de las estaciones ............ 3 Funcionamiento manual de los programas ............ 5 Ajuste del Tiempo de funcionamiento de la estación 6 Ajuste del Tiempo de inicio del programa ............. 7 A

Summary of the content on the page No. 14

Ajuste de hora/fecha Ajuste del factor % de ajuste de temporada 1. Gir e el Dial de Función a Día/hora actual . Los 1. Utilice el Selector de programas para seleccionar el dígitos de la hora comenzarán a parpadear. programa A, B, C o D. 2. Gire el Dial de función a Ajuste de temporada . 2. Ajuste la visualización pulsando el botón o . 3. Pulse el botón o para ajustar el valor % para el NOTA: Mantenga pulsado cualquiera de l

Summary of the content on the page No. 15

NOTA: El ajuste del valor % en Off impide el Ajuste del retardo de lluvia funcionamiento de todos los programas para todo el mes. NOTA: El símbolo % aparecerá para indicar que se ha 1. Gire el Dial de función a OFF . aplicado un factor % de Ajuste de temporada. 2. Pulse el botón o para seleccionar el número de días de retardo del funcionamiento, de 1 a 14. 3. Gire el Dial de función a FUNCIONAMIENTO . NOTA: OFF y e

Summary of the content on the page No. 16

Funcionamiento manual programado Funcionamiento manual de las estaciones 1. Gire el Dial de función a Estaciones manuales . IMPORTANTE: El funcionamiento Manual Verdadero 2. Pulse el botón para seleccionar el número de la anulará todos los límites de detección de caudal. estación. Funcionamiento Manual Verdadero 3. Pulse el botón o para seleccionar un tiempode 1. Gire el Dial de función a Estaciones manuales . funcionamientomanual (1 minuto – 8 horas

Summary of the content on the page No. 17

3. Pulse el botón para iniciar el ciclo de riego. Se pondrá Cuando • el funcionamiento manual haya finalizado, se en marcha la primera estación de la secuencia. reanudará el modo automático. Comenzarán a parpadear el identificador del programa Para • avanzar en la secuencia de estaciones, pulse el y el icono. botón . 4. Gire el Dial de función a FUNCIONAMIENTO . Para • terminar el funcionamiento manual en cualqui

Summary of the content on the page No. 18

• Funcionamiento de programas múltiples • Para desconectar una estación activa y poner en marcha la siguiente estación de la secuencia, sitúe 1. Gire el Dial de función a Programas manuales . adecuadamente el Selector de programas (si es 2. Utilice el Selector de programas para seleccionar el necesario) para seleccionar el programa y, a programa A, B, C o D. continuación, pulse el botón . 3. Pulse el botón para iniciar el program

Summary of the content on the page No. 19

4. Pulse el botón o para ajustar el tiempo de NOTA: No se puede seleccionar un número de tiempo de funcionamiento de la estación de Off (-- -- --) a 8 horas inicio asignado a otro programa. Si se están utilizando las (en incrementos de 1 minuto). Si está configurado el 16 asignaciones del tiempo de inicio, aparecerá NINGUNA formato de segundos, el tiempo de funcionamiento de la en la pantalla. estación puede ajustarse de 0

Summary of the content on the page No. 20

Para ajustar Días pares o impares: Ajuste del Calendario de días de riego 1. Utiliceel Selector deprogramas paraseleccionar el Nota: Si el programa está actuado con un Intervalo o un programa A, B, C o D. calendario Par/Impar, primero deberá eliminarse con el fin de 2. Gire el Dial de función a la posición Impar/Par . seleccionar otro formato. 3. Pulse el botón o para seleccionar IMPAR o PAR. Para ajustar Días naturales: 4. Para ex


Alternative user manuals
# User manual Category Download
1 Toro 24 User manual Sprinkler 56
2 Toro 34XX-10-XX User manual Sprinkler 9
3 Toro 36 User manual Sprinkler 10
4 Toro 53763 User manual Sprinkler 0
5 Toro 48 User manual Sprinkler 11
6 Toro 53764 User manual Sprinkler 4
7 Toro 640 User manual Sprinkler 103
8 Toro 53707 User manual Sprinkler 5
9 Toro 53709 User manual Sprinkler 16
10 Toro 690 User manual Sprinkler 49
11 Toro 570Z PRX User manual Sprinkler 46
12 Toro 69X-02-XX User manual Sprinkler 17
13 Toro 69X-01-XX User manual Sprinkler 5
14 Toro 69X-06-XX User manual Sprinkler 3
15 Toro 830S User manual Sprinkler 25
16 Sony CD-7335 User manual Sprinkler 1
17 Agilent Technologies Agilent Oscilloscopes, Agilent Mixed-Signal Oscilloscopes 24A User manual Sprinkler 0
18 Agilent Technologies Agilent Oscilloscopes, Agilent Mixed-Signal Oscilloscopes 54621A User manual Sprinkler 4