Black Box ServSensor EXP DC16 user manual

User manual for the device Black Box ServSensor EXP DC16

Device: Black Box ServSensor EXP DC16
Category: Server
Manufacturer: Black Box
Size: 11.17 MB
Added : 9/8/2014
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Black Box ServSensor EXP DC16. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Black Box ServSensor EXP DC16.

For your convenience

If looking through the Black Box ServSensor EXP DC16 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Black Box ServSensor EXP DC16 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Black Box ServSensor EXP DC16 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Black Box ServSensor EXP DC16 User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Black Box ServSensor EXP DC16 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Black Box ServSensor EXP DC16. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

March 2010
EME1DC16
ServSensor EXP DC16
Adds 16 opto-isolated dry contacts,
®
BL A CK BOX
so you can monitor more data points
from a ServSensor V4E.
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) •
Customer
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 •
Support
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 •
Information
Web site: www.blackbox.com • E-mail: info@blackbox.c

Summary of the content on the page No. 2

ServSensor EXP DC16 Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. We‘re here to help! If you have any questions about your application or our products, contact Black Box Tech Support at 724-746-5500 or go to blackbox.com and click on “Talk to Black Box.” You’ll be live with one of our technical experts in less tha

Summary of the content on the page No. 3

FCC and IC RFI Statements Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 o

Summary of the content on the page No. 4

ServSensor EXP DC16 Instrucciones de Seguridad (Normas Oficiales Mexicanas Electrical Safety Statement) 1. T odas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. T odas las instrucciones de operación y uso deben ser seguidas. 5. El ap

Summary of the content on the page No. 5

Table of Contents Table of Contents 1. Specifications ....................................................................................................................................................................................... 6 2. Overview .............................................................................................................................................................................................. 7 2.1 Introduction ................................

Summary of the content on the page No. 6

ServSensor EXP DC16 1. Specifications Components: Manufactured using highly integrated, low-power surface-mount technology to ensure long-term reliability Data Transfer Rate: 115.2 kbps Expandability/E-modules: Daisychain multiple E-modules, including EME1X8 and EME1DC16, uses standard RJ-45 connections and CAT5 LAN cable, connect up to 600 intelligent sensors Maximum Cable Length: 1000 ft. (300 m) Mean Time Between Failures (MTBF): 400,000 hours Network Interface: (1) standard 10/100BASE-T

Summary of the content on the page No. 7

Chapter 2: Overview 2. Overview 2.1 Introduction The ServSensor EXP DC16 (EME1DC16) expansion module extends the ServSensor V4E (EME134A) capabilities by connecting an additional 16 opto-isolated dry contacts. This increases the number of data points that can be monitoried from a single ServSensor V4E. 2.2 What’s Included Your ServSensor EXP DC16 package should contain the following items. If anything is missing or damaged, contact Black Box Technical Support at 724-746-5500 or info@blackbo

Summary of the content on the page No. 8

ServSensor EXP DC16 2.3 Hardware Description 2.3.1 Front Panel Figure 2-1 shows the ServSensor EXP DC16’s front panel, and Table 2-1 describes its components. 4 1 2 3 Figure 2-1. Front panel. Table 2-1. Front panel components. Number Component Description 1 Power LED Lights continuously when the ServSensor EXP DC16 is powered on. If the LED is flashing, there is a problem with the CPU. 2 Link LED Lights when a network connection is present. 3 RJ-45 ports Expansion In/Expansion Out ports.

Summary of the content on the page No. 9

Chapter 2: Overview 2.3.2 Back Panel Figure 2-2 shows the ServSensor EXP DC16’s back panel, and Table 2-3 describes its components. 6 5 Figure 2-2. Back panel. Table 2-3. Back panel components. Number Component Description 5 (16) 2-pin ports The 2-pin dry contact ports, numbered 1–16, are used to connect the input voltage. 6 (1) barrel connector This is a 7.5-VDC plug. Use a 7.0–9-V, 2.5-A power supply (included). 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com Page 9

Summary of the content on the page No. 10

ServSensor EXP DC16 3. Installation 3.1 Connecting to the Base Unit To connect the ServSensor EXP DC16 to the ServSensor V4E, follow the steps listed below. 1. Connect the cable to your chosen port. See Figure 3-1. Figure 3-1. E1 port. 2. Connect the other end to the “E-in” port. See Figure 3-2. Figure 3-2. E-in port. NOTE: Make sure that the 7.5 volt power supply is connected. The expansion modules can be mounted in either a standard configuration or a daisychained configuration, as shown i

Summary of the content on the page No. 11

Chapter 3: Installation In the example shown in Figure 3-3, two expansion modules are connected from two separate expansion ports on the ServSensor. In the example shown in Figure 3-4, the same two modules are connected to one expansion port in a daisychain configuration. Figure 3-4. Daisychained configuration. 3.2 Setting up a Sensor (Standard Configuration) This section describes the basic setup of a dry contact sensor in a standard configuration. It focuses on the dry contact sensor; ho

Summary of the content on the page No. 12

ServSensor EXP DC16 Figure 3-6. Summary page. The dry contact sensor should be listed along with its current reading and status. 4. Click on the dry contact sensor’s name (indicated in previous screen). The Sensors page appears. Figure 3-7. Sensors page. NOTE: You can also access this page by clicking on the Sensors tab at the top of the page. 5. Extended ports are listed from 1–4 on the left side of the sensor menu page. Page 12 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com

Summary of the content on the page No. 13

Chapter 3: Installation Figure 3-8. Sensors menu. 6. Click on the dry contact sensor icon (or another type of sensor icon). 7. The page shown in Figure 3-9 appears. Figure 3-9. Sensor Settings page. As with the ServSensor V4E, the procedure for changing sensor values remains the same. For more information on sensor set- tings, refer to the ServSensor (EME134A) manual or individual sensor manual. 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com Page 13

Summary of the content on the page No. 14

ServSensor EXP DC16 3.3 Setting up a Sensor (Daisychained Configuration) This section describes the basic setup of a sensor in a daisychained configuration. It focuses on the dry contact sensor; however, this basic setup process applies to all compatible sensors. If you require information on specific functions of a particular sensor, then download the manual for that sensor from our Web site or locate it on your product CD. Connect the two modules together by following the instructions belo

Summary of the content on the page No. 15

Chapter 3: Installation 3. When the unit is connected, the LEDs will enter the boot-up sequence indicating that the expansion module (EME1DC16) is communicating with your ServSensor V4E (EME134A). 4. Plug a sensor into one of the dry contact ports on the rear panel of the unit. In this example, we will use Port 1. Figure 3-12. Plug sensor into Port 1. 5. After the unit is connected, access your Web interface, type the desired IP address into your browser and log in, and navigate to the sum

Summary of the content on the page No. 16

ServSensor EXP DC16 Figure 3-14. Sensors page. 7. Click on any available sensor icon (see Figure 3-15). The settings for that particular sensor will appear as shown in Figure 3-16. Figure 3-15. Temperature sensor settings icon. Page 16 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com

Summary of the content on the page No. 17

Chapter 3: Installation Figure 3-16. Sensor Settings page. 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com Page 17

Summary of the content on the page No. 18

ServSensor EXP DC16 4. Notifications Set up a notification to define what to do when the sensor gives a reading beyond your previously set thresholds. This allows you to determine how you will be notified that a sensor's reading has reached the specified parameters (high warning, critical, etc.). 4.1 Adding a Notification 1. Login as the administrator. 2. Click the “Notification” tab. 3. Click the “Notification Wizard.” Figure 4-1 appears. Figure 4-1. Notification Wizard tab. 4. The Notificati

Summary of the content on the page No. 19

Chapter 4: Notifications Figure 4-2. Notification Wizard page. NOTE: Next you’ll see a sample notification. To learn what the other types of notifications do, refer to the separate notification manuals on your product CD. 4.2 SNMP Traps Set up a notification via SNMP trap, so that when your sensor reaches a certain threshold it will send a notification to your SNMP server. 1. Log in as the administrator. 2. Click on the “Notifications” tab. 3. Choose “Notifications Wizard.” 4. Select “SNMP

Summary of the content on the page No. 20

ServSensor EXP DC16 Figure 4-3. SNMP Trap screen. 5. Fill in the following information: • Enter a name for the SNMP notification. • Enter the IP address of the SNMP trap. 6. Press the “Add Trap Destination” button. 7. Input another trap or click the “Next” button. The screen shown in Figure 4-4 appears. Figure 4-4. SNMP Trap Notification screen. 8. Enter the Maximum Times to Resend and the Resend Intervals (secs). These parameters set the maximum number of times to send the trap notification


Alternative user manuals
# User manual Category Download
1 Black Box LES1216A-R2 User manual Server 17
2 Black Box EME1DC16 User manual Server 0
3 Black Box 5000 User manual Server 1
4 Black Box LES1132A User manual Server 1
5 Black Box LES1248A-R2 User manual Server 13
6 Black Box 26589 User manual Server 0
7 Black Box LES1116A User manual Server 4
8 Black Box LES1208A-R2 User manual Server 1
9 Black Box EME144A-R2 User manual Server 1
10 Black Box LES1432A User manual Server 0
11 Black Box LES1408A User manual Server 0
12 Black Box LES431A User manual Server 7
13 Black Box LES1332A User manual Server 1
14 Black Box LES144BA User manual Server 0
15 Black Box LES1416A User manual Server 0
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9