B&B Electronics ESR901W232 user manual

User manual for the device B&B Electronics ESR901W232

Device: B&B Electronics ESR901W232
Category: Server
Manufacturer: B&B Electronics
Size: 0.52 MB
Added : 9/8/2014
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for B&B Electronics ESR901W232. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with B&B Electronics ESR901W232.

For your convenience

If looking through the B&B Electronics ESR901W232 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual B&B Electronics ESR901W232 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual B&B Electronics ESR901W232 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
B&B Electronics ESR901W232 User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual B&B Electronics ESR901W232 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to B&B Electronics ESR901W232. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1







( (R RS S--2 23 32 2//4 42 22 2//4 48 85 5) )
Vlinx Wireless
Vlinx Wireless
Serial Servers

Serial Servers

M Mo od de ells s::
E ES SR R9 90 01 1W W2 23 32 2,, E ES SR R9 90 01 1W W4 48 85 5,,
E ES SR R9 90 02 2W W,, E ES SR R9 90 04 4W W




Documentation Number: ESR90xW-4905m pn#6876-rev001 Documentation Number: ESR90xW-4905m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.c

Summary of the content on the page No. 2

International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109 Technical Support e-mail: support@bb.elec.com -- Fax (815) 433-5104 European Headquarters B&B Electronics Ltd. Westlink Commercial Park Oranmore, Co. Galway, Ireland Phone +353 91-792444 -- Fax +353 91-792445 Website: www.bb-europe.com

Summary of the content on the page No. 3

© 2005 B&B Electronics. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part of B&B Electronics. B&B Electronics shall not be liable for incidental or consequential damages

Summary of the content on the page No. 4

CHAPTER 5: ADJUSTING THE BEHAVIOR OF DEVICE COMMUNICATION PORTS ................................................................................. 21 T Ta ab blle e o of f C Co on nt te en nt ts s POLLING STRINGS.................................................................................................... 22 TIMEOUTS................................................................................................................ 22 DATA QUANTITIES................................

Summary of the content on the page No. 5

Introduction Introduction Features C Ch ha ap pt te er r 1 1: : IIn nt tr ro od du uc ct tiio on n • Backward compatibility with 802.11b (up to 11 Mbps) • Multi-interface serial ports o The Vlinx 901W232 features one RS-232 serial port using a Thank you for purchasing a Vlinx ESR90xW Wireless Serial Server! standard DB-9M connector Like all B&B Electronics products, your serial server has been manufactured o The Vlinx 901W485 features one RS-422/485 serial port using to high s

Summary of the content on the page No. 6

Introduction Introduction 802.11 Wireless Networking Virtual COM Mode IEEE 802.11 is a set of standards that defines how multiple devices can Virtual COM Mode allows application programs to effectively extend their communicate on a wireless network. The standard has grown into a set of COM ports across the network. Data sent to that port is redirected via the several standards that define various features and functions. The 802.11g network to a COM port on the serial server. Windows p

Summary of the content on the page No. 7

Introduction Introduction ESR90xW Startup Procedure IEEE 802.11g Setup and configuration of your Vlinx ESR90xW wireless serial server is IEEE 802.11g standard specifies a WLAN that operates on the 2.4 GHz band fast, straightforward and simple. You have several options from which to at data rates up to 54 Mbps, but is backward compatible with the earlier choose. The following procedure outlines an easy way to get your server set 802.11b standard (which operates at up to 11 Mbps). Sys

Summary of the content on the page No. 8

Introduction Introduction 4. Set Up PC 1. Configure the PC to work in the 192.168.0.x private address range 2. Open a web browser 3. Enter 192.168.0.200 into the address bar of the browser Figure 1. Direct Connection for Configuration 3. Power Up 1. Apply power to the ESR90xW 2. Front panel LED will illuminate with the following sequence: Figure 3. Web Console Device Information Page a. Power LED will always be lit while device is powered 5. Configuration b. Signal Strength L

Summary of the content on the page No. 9

Vlinx ESR90xW Hardware Vlinx ESR90xW Hardware Hardware Features C Ch ha ap pt te er r 2 2: : V Vlliin nx x E ES SR R9 90 0x xW W H Ha ar rd dw wa ar re e Indicators Power LED Package Checklist Red: Indicates the device is receiving power from an external source Vlinx ESR90xW Wireless Serial Servers are shipped with the following Signal Strength LED items included: Tri-color: Indicates the connection quality: A Vlinx ESR901W232, ESR901W485, ESR902W or ESR904W Wire

Summary of the content on the page No. 10

Vlinx ESR90xW Hardware Vlinx ESR90xW Hardware Connectors RS-485 Receiver Biasing Configuration Port Connector Vlinx ESR90xW wireless serial servers provide built-in receiver biasing on One standard RJ-45 receptacle that allows the serial server to be connected to RS-485 ports (includes the 902W485 port, 902W Port 2 and 904W Ports 2 personal computer for programming, troubleshooting and device and 4). The Data(+) line is pulled up to 3.3V supply using a 4.7 k Ω resistor configuratio

Summary of the content on the page No. 11

Vlinx ESR90xW Hardware Vlinx ESR90xW Hardware For wireless configuration, or for typical infrastructure mode operation, the Vlinx ESR90xW communicates with a wireless access point, which is connected to a PC via a wired network. Figure 7. Connection via the Wireless LAN Other Hardware Connections Serial tunneling can occur between two ESR90xW serial servers communicating with individual access points and across a wired network. Figure 8. Serial Tunneling via Infrastructure D

Summary of the content on the page No. 12

Web Console Web Console You can change the Device Name of the serial server by typing in a different name Chapter 4: Device Configuration via Chapter 4: Device Configuration via For changes to take effect on this or any other Web Console page, you must Web Console Web Console click the Apply button before navigating away from the page. Configuring the Serial Port The Web Console can be used to configure your Vlinx ESR90xW Wireless Serial Server from any web browser software (such

Summary of the content on the page No. 13

Web Console Web Console • Connection Protocol (RAW Client, RAW Server, Virtual COM Port Server, RFC2217 Client) • Server (Remote) IP Address • Server (Remote) Port • Local Port • Send Serial Data to Ethernet… conditions For explanations of these configuration parameters see Adjusting the behavior of device communication ports. Configuring Network Properties To view or change network properties, click Network on the Web Console banner. The Device Network Settings appears. This page

Summary of the content on the page No. 14

Web Console Web Console Figure 13. The Vlinx Web Console Users Page Using Device Status Information To view or change device status properties, click Status on the Web Console banner. The following page will appear: Figure 14. The Vlinx Web Console Status Page Documentation Number: ESR90xW-4905m Chapter 4 19 20 Chapter 4 Documentation Number: ESR90xW-4905m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-ele

Summary of the content on the page No. 15

Device Communication Ports Device Communication Ports Polling Strings Chapter 5: Adjusting the Behavior of Chapter 5: Adjusting the Behavior of Polling strings are used when you want the ESR90xW to look for a specific data pattern before taking the data in it’s serial buffer and creating an Ethernet packet with Device Communication Ports Device Communication Ports it. Polling strings can be configured to monitor not only the serial traffic but the Ethernet traffic as well. There i

Summary of the content on the page No. 16

Device Communication Ports Device Communication Ports VCOM Port Setup C Ch ha ap pt te er r 6 6: : D De ev viic ce e D Diis sc co ov ve er ry y a an nd d To install and manage Virtual COM ports, Serial IP software will be provided. The software will be installed in the start menu at Serial-IP. To run the setup Virtual COM Ports Virtual COM Ports software, choose Control Panel and this screen will be displayed: Device Detection Utility To find devices on a wireless network,

Summary of the content on the page No. 17

Vlinx ESR90xW Technical Data Vlinx ESR90xW Technical Data Parity: None, Even, Odd, Mark, Space Data Bits: 5, 6, 7 or 8 A Ap pp pe en nd diix x A A: : V Vlliin nx x E ES SR R9 90 0x xW W T Te ec ch hn niic ca all D Da at ta a Stop Bits: 1, 1.5 or 2 Set-up Options: Vlinx Web Console Configuration Product Specifications Configuration Modes: Direct TCP Server, Client Virtual COM Port Connection Serial Server Model: Vlinx ESR901W232, Vlinx ESR901W485, Vlinx ESR902W or Vlinx Pair

Summary of the content on the page No. 18

Vlinx ESR90xW Technical Data Vlinx ESR90xW Technical Data Default Server Properties Vlinx ESR90xW Dimensional Diagrams Server Name Vlinx ESR901W232 or Vlinx ESR901W485 or Vlinx ESR902W or Vlinx ESR904W Serial Number: (printed on bottom of unit) Password: Blank DHCP: Disable IP Address: 192.168.0.200 Net Mask: 255.255.255.0 Gateway: 192.168.0.254 MAC Address: Fixed – see bottom label Version&Date: current firmware version number & date Serial server port: 1 Figure 15. Dime

Summary of the content on the page No. 19

Vlinx ESR90xW Technical Data Vlinx ESR90xW Technical Data Figure 17. Dimensional Diagram of the Vlinx 902W Figure 18. Dimensional Diagram of the Vlinx 904W Documentation Number: ESR90xW-4905m Appendix A 29 30 Appendix A Documentation Number: ESR90xW-4905m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-510

Summary of the content on the page No. 20

RXDA(-)/Data(-) RXDB(+)/Data(+) TXDB(+) TXDA(-) GND RS-232/422/485 Connections RS-232/422/485 Connections A Ap pp pe en nd diix x B B: : R RS S- -2 23 32 2//4 42 22 2//4 48 85 5 C Co on nn ne ec ct tiio on ns s Terminal Block Pin-out for RS-422 and RS-485 (Vlinx ESR901W485 only) DB-9 Pin-outs for RS-232 and RS-232/422/485 Connections 1 2 3 4 5 DB-9M RS-232 RS-232 DTE RS-422 RS-485 Pin Signal Name 1 Carrier Detect DCD In TXDA(-) 2 Receive Data RXD In TXDB(+) 3 Transmit Da


Alternative user manuals
# User manual Category Download
1 B&B Electronics RS-422 User manual Server 0
2 B&B Electronics ESR902W User manual Server 0
3 B&B Electronics VLINX WIRELESS SERIAL User manual Server 1
4 B&B Electronics Multi-Interface Ethernet Serial s User manual Server 0
5 B&B Electronics RS-485 User manual Server 0
6 B&B Electronics ESR904W User manual Server 0
7 B&B Electronics ESP904 User manual Server 1
8 B&B Electronics ESP904E User manual Server 0
9 B&B Electronics RS-232 User manual Server 0
10 B&B Electronics ESR901W485 User manual Server 0
11 Edelbrock 1921 User manual Server 0
12 Sony VAIO VGF-HS1 User manual Server 11
13 Sony NAS-SV20DI User manual Server 1
14 3Com 10031370-01 User manual Server 1
15 3Com SuperStack 3 User manual Server 9