MSi MS-9246 user manual

User manual for the device MSi MS-9246

Device: MSi MS-9246
Category: Server
Manufacturer: MSi
Size: 7.56 MB
Added : 7/15/2014
Number of pages: 123
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MSi MS-9246. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MSi MS-9246.

For your convenience

If looking through the MSi MS-9246 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MSi MS-9246 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MSi MS-9246 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MSi MS-9246 User manual - Online PDF
Advertisement
« Page 1 of 123 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MSi MS-9246 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MSi MS-9246. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MS-9246 1U Rackmount Server
English Version
G52-S9246X1
i

Summary of the content on the page No. 2

Manual Rev: 1.0 Release Date: July 2004 FCC-A Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruct

Summary of the content on the page No. 3

Copyright Notice The material in this document is the intellectual property of MICRO-STAR INTERNATIONAL. We take every care in the preparation of this document, but no guarantee is given as to the correctness of its contents. Our products are under continual improvement and we reserve the right to make changes without notice. Trademarks All trademarks are the properties of their respective owners. ® ® Intel and Pentium are registered trademarks of Intel Corporation. ® PS/2 and OS /2 are registe

Summary of the content on the page No. 4

Safety Instructions 1. Always read the safety instructions carefully. 2. Keep this User’s Manual for future reference. 3. Keep this equipment away from humidity. 4. Lay this equipment on a reliable flat surface before setting it up. 5. The openings on the enclosure are for air convection hence protects the equip- ment from overheating. DO NOT COVER THE OPENINGS. 6. Make sure the voltage of the power source and adjust properly 110/220V be- fore connecting the equipment to the power inlet. 7. Plac

Summary of the content on the page No. 5

CONTENTS FCC-A Radio Frequency Interference Statement .......................................................... ii Copyright Notice ........................................................................................................... iii Trademarks .................................................................................................................... iii Revision History .........................................................................................................

Summary of the content on the page No. 6

Chapter 3. Mainboard Hardware ......................................................................... 3-1 Quick Components Guide ................................................................................... 3-2 Central Processing Unit: CPU ............................................................................. 3-3 CPU Installation Procedures for Socket 604 .............................................. 3-4 Memory .....................................................................

Summary of the content on the page No. 7

Appendix A: SCSI BIOS Setup (Optional) .......................................................... A-1 Entering SCSI BIOS ............................................................................................ A-2 Control Keys .............................................................................................. A-2 Selecting the SCSI Channel ....................................................................... A-2 Selecting the Management Type .....................................

Summary of the content on the page No. 8

Getting Started Chapter 1. Getting Started Getting Started The MS-9246 1U Rackmount Server is a high-performance ® TM barebone system powered by dual Intel Xeon processors, Lindenhurst MCH, ICH5R/PXH PCI Bridges, and NS PC87366-ICK/VLA I/O Bridge. With high scalability, reliability, ease of use, and overall value, the MS-9246 makes an ideal choice for value conscious customers. 1-1

Summary of the content on the page No. 9

MS-9246 1U Rackmount Server Packing Checklist Unpack the package and check if all items listed below are present. If any item contained in the package is damaged or missing, please contact your local dealer for replacement. In addition, keep the box and packing materials for possible future use. Your MS-9246 1U Rackmount Server Barebone package should contain the following items: MS-9246 1U Rackmount Server (includes a mainboard, an SSI EPS 1U Power Supply and a Fan Duct ) User’s Guide Server Dr

Summary of the content on the page No. 10

Getting Started Ear Set Rail Set Power Supply Options Single Power 1 + 1 Redundant Power 1 Redundant Power 1-3

Summary of the content on the page No. 11

MS-9246 1U Rackmount Server System Overview This section shows the configuration of the MS-9246 from different angles, and the connectors and buttons on the front and back panel. Top View 7 8 6 5 4 2 3 1 1 HDD Tray 2 Slim CD-ROM Drive 3 Slim Floppy Disk Drive 4 Axial Fan Module (redundant) 5 Fan Duct 6 Memory DIMM Slots 7 PCI Riser Card Bracket 8 SSI EPS 1U Power Supply 1-4

Summary of the content on the page No. 12

Getting Started Front View 1 2 3 Front Bezel 8 9 6 5 4 10 7 11 13 12 CD-ROM Drive 1 Slim CD-ROM Drive Floppy Disk Drive 2 Slim Floppy Disk Drive HDD Bay 3 Swappable Hard Disk Drive Bays Port 4 Serial Port 5 USB Ports 1-5

Summary of the content on the page No. 13

MS-9246 1U Rackmount Server LED 6 Power LED This indicator shows the power status of the system. It glows when the main power is turned on. 7 HDD Activity LED This indicator shows the activity status of the hard disk drive. It flashes when the system is accessing data on the hard disk and remains off when no disk activity is detected. 8 Status LEDs of LAN# 1/2 1. The green LED is on when there is an active connection on the LAN port. 2. This LED flashes when transmitting or receiving activi

Summary of the content on the page No. 14

Getting Started Front Bezel LEDs LED Color State Description Power/Sleep Green On Legacy power on/ACPI S0 state Blink (~1/sec) Sleep/ACPI S1 state Off Off Power off/ACPI S4, S5 state HDD Activity Green Blink HDD accesss activity Off Off No disk activity LAN1/LAN2 Activity Green On LAN link Green Blink LAN access activity System Status Green On Running/normal operation w/ BMC Amber On Critical or non-recoverable condition Amber Blink Non-critical condition Off Off POST/system stop System Sta

Summary of the content on the page No. 15

MS-9246 1U Rackmount Server Diagnostic LEDs: DLED1/DLED2/DLED3/DLED4 Memory LEDs:D29/D30/D31/D32/D33/D35 Component LEDs and four Diagnostic LEDs are integrated onboard, helping users diagnose their systems. When POST or Service Processor detects an error, the corresponding LEDs light up to alert users to the condition and help service personnel identify the failing component. A system status LED on the front panel of the system first alerts users that an error has occurred. Service personn

Summary of the content on the page No. 16

Getting Started D-LEDs Description Processor Initialization 1 2 - This will show information regarding the processor (like brand 3 4 name, system bus, etc...) Testing RTC (Real Time Clock) 1 2 3 4 BIOS Sign On 1 2 - This will start showing information about logo, processor brand 3 4 name, etc... Testing Base and Extended Memory 1 2 - Testing base memory from 240K to 640K and extended m

Summary of the content on the page No. 17

MS-9246 1U Rackmount Server Rear View Rear Bezel 9 5 6 7 8 1 2 3 4 1 2 VGA Port Gigabit LAN Jacks 3 4 USB Ports Serial Port 5 6 NMI Switch System ID Button 7 8 System ID LED Ultra320 SCSI Connector 9 PS/2 Keyboard/Mouse Connector (through Y-type converter) Rear Bezel LEDs LED Color State Description RJ45 NIC 1 Linkage Green On LAN linked /RJ45 NIC 2 Linkage Green Blinking LAN accessing Off Off No LAN linked RJ45 NIC 1 Access Yellow On Gigabit mode access /RJ45 NIC 2 A

Summary of the content on the page No. 18

Getting Started Mouse/Keyboard Connector USB Port Pin5 PIN SIGNAL Pin6 1 2 3 4 Keyboard Clock Mouse Clock 1 VCC 2 -Data 3 +Data 4 GND Pin4 VCC Pin3 GND SCSI Connector Pin2 Pin1 Mouse Data Keyboard Data 34 1 68 35 Serial Port PIN SIGNAL 68-Pin Ultra320 SCSI Connector 1DCD 1 2 3 4 5 2 SIN Pin Description Pin Description 3 SOUT 4 DTR 1 +DB(12) 35 -DB(12) 5 GND 2 +DB(13) 36 -DB(13) 6 DSR 3 +DB(14) 37 -DB(14) 7 RTS 6 7 8 9 8 CTS 4 +DB(15) 38

Summary of the content on the page No. 19

MS-9246 1U Rackmount Server System Specifications Mainboard MS-9146 server board CPU ® TM Dual Intel Xeon (800MHz FSB) processors in 604-pin package 1MB L2 cache 6.4GB/s transmission rate Core voltage: 1.10~1.40V VTT: 1.2V Chipset ® MCH: Intel Lindenhurst (E7520) Memory Controller Hub ® ® PCI Bridge: Intel PXH; Intel ICH5R I/O Bridge: NS PC87366-ICK/VLA Memory Bus Feature Supports six dual-channel DDR266 (4-DIMM per channel)/DDR333 (3-DIMM per channel) registered ECC DIMMs Chipkill Su

Summary of the content on the page No. 20

Getting Started 1 serial port 1 VGA port 2 RJ-45 Gigabit LAN jacks NMI switch/system ID button/system ID LED Network ® Intel 82546GB Gigabit Ethernet Controller Server Management (Optional) QLogic Zircon UL BMC (Baseboard Management Controller) - Incorporates an embedded microcontroller, two System Management Bus ® (SMBus ) interfaces, a Chassis Management interface, Bi-color LED control, an integrated EEPROM, Fan control, ADC channels, and Digital Input Event and General-Purpose Input/Out


Alternative user manuals
# User manual Category Download
1 MSi MS-9258 User manual Server 0
2 Edelbrock 1921 User manual Server 0
3 Sony VAIO VGF-HS1 User manual Server 11
4 Sony NAS-SV20DI User manual Server 1
5 3Com 10031370-01 User manual Server 1
6 3Com SuperStack 3 User manual Server 9
7 3Com CS/2500 User manual Server 11
8 8e6 Technologies 8e6 Enterprise Reporter Administrator Console ER User manual Server 0
9 Accton Technology Fike Cheetah FS-8700-48 User manual Server 10
10 Acer AR380 F1 User manual Server 1
11 Acer Altos G300 Series User manual Server 4
12 Acer Altos R310 User manual Server 4
13 Acer Altos G701 User manual Server 4
14 Acer Altos G300 User manual Server 0
15 Acer AT350 User manual Server 2