HP (Hewlett-Packard) ProLiant DL385 user manual

User manual for the device HP (Hewlett-Packard) ProLiant DL385

Device: HP (Hewlett-Packard) ProLiant DL385
Category: Server
Manufacturer: HP (Hewlett-Packard)
Size: 7.42 MB
Added : 11/10/2014
Number of pages: 174
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for HP (Hewlett-Packard) ProLiant DL385. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with HP (Hewlett-Packard) ProLiant DL385.

For your convenience

If looking through the HP (Hewlett-Packard) ProLiant DL385 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual HP (Hewlett-Packard) ProLiant DL385 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual HP (Hewlett-Packard) ProLiant DL385 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
HP (Hewlett-Packard) ProLiant DL385 User manual - Online PDF
Advertisement
« Page 1 of 174 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual HP (Hewlett-Packard) ProLiant DL385 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to HP (Hewlett-Packard) ProLiant DL385. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HP ProLiant DL385 Server
User Guide

March 2005 (Second Edition)
Part Number 376536-002

Summary of the content on the page No. 2

© Copyright 2004, 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft, Windows, and Windows NT are U.S. registered tra

Summary of the content on the page No. 3

3 Contents Server component identification 9 Front panel components.....................................................................................................................10 Front panel LEDs and buttons............................................................................................................11 Rear panel components ......................................................................................................................12 Rear panel LEDs and

Summary of the content on the page No. 4

4 HP ProLiant DL385 Server User Guide Front fan bracket ................................................................................................................................43 Server setup 45 Optional installation services .............................................................................................................45 Rack planning resources ....................................................................................................................46 Opt

Summary of the content on the page No. 5

Contents 5 Server cabling 85 Cabling...............................................................................................................................................85 SAS model cabling ............................................................................................................................85 SAS hard drive cabling...........................................................................................................86 USB cabling....................

Summary of the content on the page No. 6

6 HP ProLiant DL385 Server User Guide HP Systems Insight Manager................................................................................................113 Redundant ROM support......................................................................................................114 System maintenance menu ...................................................................................................115 iLO ROM-Based Setup Utility ...............................................

Summary of the content on the page No. 7

Contents 7 Regulatory compliance notices 155 Federal Communications Commission notice..................................................................................155 FCC rating label....................................................................................................................155 Declaration of conformity for products marked with the FCC logo, United States only......157 Modifications.............................................................................

Summary of the content on the page No. 8

Summary of the content on the page No. 9

9 Server component identification In this section Front panel components................................................................................................................10 Front panel LEDs and buttons......................................................................................................11 Rear panel components.................................................................................................................12 Rear panel LEDs and buttons ......

Summary of the content on the page No. 10

10 HP ProLiant DL385 Server User Guide Front panel components Item SCSI model (top) SAS model (bottom) 1 Hard drive bays Hard drive bays 2 USB port USB port 3 Bay for tape drive or hard drive — with tape drive blank 4 Diskette drive bay Diskette drive bay 5 DVD/CD-ROM drive DVD/CD-ROM drive

Summary of the content on the page No. 11

Server component identification 11 Front panel LEDs and buttons Item Description Status 1 Internal health LED Green = Normal Amber (flashing) = System degraded. Refer to system board LEDs to identify component in degraded state. Red (flashing) = System critical. Refer to system board LEDs to identify component in critical state. 2 External health LED Green = Normal (power supply) Amber (flashing) = Power redundancy failure Red (flashing) = Critical power supply failure 3 NIC

Summary of the content on the page No. 12

12 HP ProLiant DL385 Server User Guide Item Description Status 5 UID LED button Blue = Activated Blue (flashing) = System being remotely managed Off = Deactivated 6 Power On/Standby Green = System on button/system power LED Amber = System shut down, but power still applied Off = Power cord not attached or power supply failure Rear panel components Item Description Connector Color 1 PCI-X expansion slot 1, 64 bit/100 MHz, Bus A N/A 2 PCI-X expansion slot 2, 64 bit/100 M

Summary of the content on the page No. 13

Server component identification 13 Item Description Connector Color 7 Power cord connector N/A 8 Keyboard connector Purple 9 NIC 1 connector N/A 10 NIC 2 connector N/A 11 USB connectors (2) Black 12 Video connector Blue Rear panel LEDs and buttons Item Description LED Status Color 1 RJ-45 activity LED Green On or flashing = Network activity Off = No network activity 2 RJ-45 link LED Green On = Linked to network Off = Not linked to network

Summary of the content on the page No. 14

14 HP ProLiant DL385 Server User Guide Item Description LED Status Color 3 UID LED button Blue On = Activated Flashing = System remotely managed Off = Deactivated 4 Power supply LED Green On = Power turned on and power supply functioning properly Off = One or more of the following conditions exists:  AC power unavailable  Power supply failed  Power supply in standby mode  Power supply exceeded current limit System board components Item Description 1 Smart Array 6i

Summary of the content on the page No. 15

Server component identification 15 Item Description 4 PCI riser cage connector 5 DIMM slots (5-8) 6 Remote management connector 7 SCSI connector (port 2) * 8 Fan connector 9 DVD/CD-ROM drive system connector 10 Fan connector 11 SCSI connector (port 1) * 12 Fan connector 13 System maintenance switch 14 Diskette drive system connector 15 Power supply signal connector 16 Fan connector 17 System power connector 18 Processor socket 2 19 PPM for processor 2 20 DIMM slots (1-4) 21

Summary of the content on the page No. 16

16 HP ProLiant DL385 Server User Guide Position Default Function S2 Off Off = System configuration can be changed. On = System configuration is locked. S3 Off Reserved S4 Off Reserved S5 Off Off = No function On = Clears power-on password and administrator password S6 Off Off = No function On = Clear NVRAM. S7 Off Reserved S8 Off Reserved When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings

Summary of the content on the page No. 17

Server component identification 17 Systems running Microsoft® Windows® experience a blue-screen trap when the OS crashes. When this happens, Microsoft® recommends that system administrators perform an NMI event by temporarily shorting the NMI header with a jumper. The NMI event enables a hung system to become responsive again. DIMM slots DIMM slots are numbered sequentially (1 through 8) and the paired banks are identified by the letters A, B, C, and D. Item Description 1 DI

Summary of the content on the page No. 18

18 HP ProLiant DL385 Server User Guide SCSI backplane components Item Description 1 Power button/LED connector 2 SCSI connector (port 2) 3 DVD/CD-ROM drive connector 4 SCSI connector (port 1) 5 Diskette drive connector 6 Power connector 7 USB connector 8 Diskette drive system connector 9 SCSI connector (used with a jumper cable in simplex mode or terminator board in duplex mode) 10 DVD/CD-ROM drive system connector

Summary of the content on the page No. 19

Server component identification 19 SAS backplane components Item Description 1 Power button/ LED connector 2 DVD/CD-ROM drive connector 3 DVD/CD-ROM drive system connector 4 SAS connector 5 Diskette drive system connector 6 Diskette drive connector 7 SAS connector 8 Power connector 9 USB connector

Summary of the content on the page No. 20

20 HP ProLiant DL385 Server User Guide System board LEDs Item LED Description Status 1 Power good Green = Normal Off = Power failure 2 Riser interlock Amber = PCI riser cage not seated Off = PCI riser cage is seated 3 PPM 1 failure Amber = PPM failure Off = Normal 4 System Amber = Cautionary or critical temperature overtemperature level detected Off = Temperature OK 5 Processor 2 Amber = Cautionary or critical temperature overtemperature level detected Off = Temperature


Alternative user manuals
# User manual Category Download
1 HP (Hewlett-Packard) 11I V1 User manual Server 32
2 HP (Hewlett-Packard) 5971-0825 User manual Server 16
3 HP (Hewlett-Packard) 11I V2 User manual Server 10
4 HP (Hewlett-Packard) 545740-002 User manual Server 19
5 HP (Hewlett-Packard) 5992-4859 User manual Server 8
6 HP (Hewlett-Packard) 5187-2725 User manual Server 2
7 HP (Hewlett-Packard) 9000 V2500 SCA User manual Server 0
8 HP (Hewlett-Packard) A7818-IE002 User manual Server 1
9 HP (Hewlett-Packard) A3661B User manual Server 3
10 HP (Hewlett-Packard) 354556-002 User manual Server 0
11 HP (Hewlett-Packard) A9834-9001B User manual Server 0
12 HP (Hewlett-Packard) AB300A User manual Server 0
13 HP (Hewlett-Packard) AA-RTDRB-TE User manual Server 0
14 HP (Hewlett-Packard) 9000 V2600 SCA User manual Server 1
15 HP (Hewlett-Packard) AMS DL320 User manual Server 4
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9