Fujitsu PRIMERGY BX960 S1 user manual

User manual for the device Fujitsu PRIMERGY BX960 S1

Device: Fujitsu PRIMERGY BX960 S1
Category: Server
Manufacturer: Fujitsu
Size: 1.29 MB
Added : 11/5/2013
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fujitsu PRIMERGY BX960 S1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fujitsu PRIMERGY BX960 S1.

For your convenience

If looking through the Fujitsu PRIMERGY BX960 S1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fujitsu PRIMERGY BX960 S1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fujitsu PRIMERGY BX960 S1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fujitsu PRIMERGY BX960 S1 User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fujitsu PRIMERGY BX960 S1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fujitsu PRIMERGY BX960 S1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operating Manual - English
PRIMERGY BX960 S1
Server Blade
Operating Manual
May 2011

Summary of the content on the page No. 2

Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to email: manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system whic

Summary of the content on the page No. 3

Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product

Summary of the content on the page No. 4

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this

Summary of the content on the page No. 5

Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) – Replacing the lithium battery BX960 S1 Operating Manual

Summary of the content on the page No. 6

Operating Manual BX960S1 © cognitas. Gesellschft für Technik-Dokumentation mbH 2011 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-7320-002.fm

Summary of the content on the page No. 7

Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.1 Concept and target groups for this manual . . . . . . . . . . 9 1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 10 1.3 Performance features . . . . . . . . . . . . . . . . . . . . . 11 1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 17 1.5 Technical data . . . . . . . .

Summary of the content on the page No. 8

Contents 5.2 Switching the Server Blade on and off . . . . . . . . . . . . . 45 5.3 Configuring the Server Blade . . . . . . . . . . . . . . . . . . 46 5.3.1 Preparing for local installation . . . . . . . . . . . . . . . . . . 46 5.3.2 Configuring the onboard SATA controller . . . . . . . . . . . . . 46 5.3.3 Configuring the server and installing the operating system with the ServerView Installation Manager . . . . . . . . . .

Summary of the content on the page No. 9

1 Introduction The PRIMERGY BX960 S1 server blade is an Intel-based quad-socket server blade. It is ideal for use in data centers belonging to enterprises or Internet service providers, and makes an excellent large application server, terminal server for compute-intensive applications or DBMS server. Security functions in the BIOS Setup protect the data on the server blade from unauthorized changes. The server blade occupies 2 bays one upon the other in the BX900 S1 system unit. I You can f

Summary of the content on the page No. 10

Documentation overview 1.2 Documentation overview I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server. If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server http://primeserver.fujitsu.com/primergy/system.html). The PDF

Summary of the content on the page No. 11

Performance features Further sources of information: – PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2 – Manual for the monitor – Documentation for the boards and drives – Operating system documentation – Information files in your operating system 1.3 Performance features Customer Self Service (CSS) The PRIMERGY Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios. In the CSS concept, yo

Summary of the content on the page No. 12

Performance features In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question. (This feature is not available for the Japanese market.) System board The features of the system board are described in the technical manual for the system board D2873 for the hardware and in the BIOS Setup chapter of this manual for the firmware. Trusted Platform Module (TPM) A Tru

Summary of the content on the page No. 13

Performance features – 10 Gbit/s Ethernet mezzanine card with 2 ports (Intel 82599EB controller) – 8 Gbit/s fiber-channel card with 2 ports (compatible with Emulex LPe12002) I If a server blade is configured with up to four mezzanine cards, this does not exclude other configurations for any of the other server blades in a BX900 S1 system unit. If you want to install mezzanine cards in server blades, the system unit must be fitted with the corresponding Fibre Channel, Infiniband and/or Ethern

Summary of the content on the page No. 14

Performance features High level of availability and data security When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method. ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system components. The PDA (Prefailure Detection and Analyzing) technology from Fujitsu Technology Solutions analyzes and monitors all compone

Summary of the content on the page No. 15

Performance features ● Automatic network configuration via DNS / DHCP ● Power supply of the iRMC S2 via the system standby supply ● Full-coverage alarm management ● System Event Log (SEL) reading and processing More information about the iRMC S2 can be found in the "iRMC S2 - integrated Remote Management Controller" user’s guide (on the ServerView Suite DVD 2 under Industry Standard Servers - Software - ServerView Suite - Out-Of-Band Management). Server management Server management is implem

Summary of the content on the page No. 16

Performance features ServerView Installation Manager You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided. User-guided menus are available for installing the server operating system (for further details see section "Configuring the Server Blade" on page 46). Service and support PRIMERGY servers are service-friendly and modular, thus enabling quick and simple maintenance. The two redundant hot-pluggable management blades of th

Summary of the content on the page No. 17

Notational conventions 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands or menu items. "Quotation marks" indicate names of chapters and terms that are being emphasized. Ê describes activities that must be performed in the order shown. V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. I indicates

Summary of the content on the page No. 18

Technical data 1.5 Technical data Electrical data Energy consumption 1,178 W (fully equipped)* Heat dissipation 4,241 kJ/h* * applies to processors up to 105 W Compliance with regulations and standards Product safety and IEC 60950-1/2 / EN 60950-1/2, ergonomics UL/CSA 60950-1/2, CNS 14336 / GB 4943 / EN 50371 Electromagnetic compatibility FCC class A CNS 13438 class A; VCCI class A AS/NZS CISPR 22 class A / GB 9254 class A GB 17625 Interference emissions EN 55022 class A Harmonic current EN

Summary of the content on the page No. 19

Technical data Certification Product safety approved with the PRIMERGY BX900 S1 system unit Global CB Germany GS, CE USA/Canada CSA /CSA US C Japan VCCI China/Taiwan BSMI Mechanical specifications Width 45 mm Depth 508 mm Height 420 mm (2 bays in the system unit) Weight Max. 12.4 kg (depending on the configuration). Ambient conditions Environment class 3K2 EN 60721 / IEC 721 Part 3-3 Environment class 2K2 EN 60721 / IEC 721 Part 3-2 Temperature: Operation (3K2) 5 ºC ... 35 ºC Transport (2K2) -20

Summary of the content on the page No. 20

Technical data 20 Operating Manual BX960S1 © cognitas. Gesellschft für Technik-Dokumentation mbH 2010 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-7322-002.fm


Alternative user manuals
# User manual Category Download
1 Fujitsu BX900 S1 User manual Server 23
2 Fujitsu 2000 User manual Server 1
3 Fujitsu CM71-00101-5E User manual Server 1
4 Fujitsu 5.0L10 User manual Server 1
5 Fujitsu 2000 SERIES User manual Server 1
6 Fujitsu Cloud Edition V3.1.0 User manual Server 0
7 Fujitsu C122-E180-01EN User manual Server 0
8 Fujitsu C120-E361-04EN User manual Server 2
9 Fujitsu M10-4S User manual Server 0
10 Fujitsu M10 User manual Server 1
11 Fujitsu M10-4 User manual Server 0
12 Fujitsu C122-H007-01EN User manual Server 0
13 Fujitsu J2X0-2273-01EN User manual Server 0
14 Fujitsu M8000 User manual Server 0
15 Fujitsu RX300 S2 User manual Server 25
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9