Fujitsu PRIMERGY BX600 S2 user manual

User manual for the device Fujitsu PRIMERGY BX600 S2

Device: Fujitsu PRIMERGY BX600 S2
Category: Server
Manufacturer: Fujitsu
Size: 4.07 MB
Added : 11/5/2013
Number of pages: 173
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fujitsu PRIMERGY BX600 S2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fujitsu PRIMERGY BX600 S2.

For your convenience

If looking through the Fujitsu PRIMERGY BX600 S2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fujitsu PRIMERGY BX600 S2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fujitsu PRIMERGY BX600 S2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fujitsu PRIMERGY BX600 S2 User manual - Online PDF
Advertisement
« Page 1 of 173 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fujitsu PRIMERGY BX600 S2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fujitsu PRIMERGY BX600 S2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PRIMERGY BX600 S2
Basic Unit
Operating Manual
Edition March 2007

Summary of the content on the page No. 2

Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@fujtsu-siemens.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which c

Summary of the content on the page No. 3

Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.1 Overview of the Documentation . . . . . . . . . . . . . . . . . 8 1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.3 Notational Conventions . . . . . . . . . . . . . . . . . . . . 14 1.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . 15 2 Overview: B

Summary of the content on the page No. 4

Contents 5 Preparation for Use and Operation . . . . . . . . . . . . . . . 49 5.1 Operating and Indicator Elements of the Basic Unit . . . . . 50 5.1.1 The Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.1.2 The Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 5.2 Switching the Basic Unit ON/OFF . . . . . . . . . . . . . . . 53 5.3 Management Blade Configuration . .

Summary of the content on the page No. 5

Contents 9 Ethernet Pass-Thru Blade . . . . . . . . . . . . . . . . . . . 99 9.1 Control and Connection Panel . . . . . . . . . . . . . . . . 100 9.2 Port Assignment of the Gigabit Ethernet Pass-Thru Blades 101 9.3 Replacing an Ethernet Pass-Thru Blade . . . . . . . . . . . 104 10 Fibre Channel Switch Blade . . . . . . . . . . . . . . . . . . 105 10.1 Control and Connection Panel . . . . . . . . . . . . . . . . 106 10

Summary of the content on the page No. 6

Contents 14 Power Supply Concept . . . . . . . . . . . . . . . . . . . . 139 14.1 Power Supply Units . . . . . . . . . . . . . . . . . . . . . . 140 14.1.1 Replacing a Power Supply Unit . . . . . . . . . . . . . . . . . 142 14.1.2 Adding a Power Supply Unit . . . . . . . . . . . . . . . . . . 145 15 Ventilation Concept . . . . . . . . . . . . . . . . . . . . . . 149 15.1 The Fan Unit . . . . . .

Summary of the content on the page No. 7

Introduction 1 Introduction The PRIMERGY BX600 S2 Blade Server System represents a highly compact, power-saving and scalable servers for integration in 19-inch rack systems. Figure 1: PRIMERGY BX600 S2 Basic Unit The PRIMERGY BX600 S2 basic unit occupies seven height units in the rack and can accommodate up to ten server blades of different models and configu- rations. As economical, ultra-compact systems, the server blades with up to eight CPUs are ideal for use by company data centers and I

Summary of the content on the page No. 8

Overview of the Documentation Introduction Security functions in the BIOS Setup protect the data on the server blades against manipulation. Additional security is provided by the lockable rack door. 1.1 Overview of the Documentation I PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is part of the PRIMERGY ServerView Suite delivered with each server system. The PDF files for the manuals can also be downloaded free of charge from the Internet. The overv

Summary of the content on the page No. 9

Introduction Overview of the Documentation – “BIOS Setup” (PDF file available on the ServerBooks DVD supplied) – “ServerView Suite” includes the ServerStart Disc 1, the ServerStart Disc 2 and the ServerBooks DVD. The PDF version of the “PRIMERGY ServerView Suite - ServerStart” user manual is also available on the ServerBooks DVD. I If you need a replacement copy of the ServerBooks DVD, send the details of your sever to the following e-mail address: Reklamat-PC-LOG@fujitsu-siemens.com – „PRIM

Summary of the content on the page No. 10

Features Introduction 1.2 Features The PRIMERGY BX600 S2 basic unit provides a high-level infrastructure for the installed server blades. Server capacity The PRIMERGY BX600 S2 basic unit provides slots for up to ten hot-pluggable server blades. For details of the performance features of the different server blade models, see the relevant operating manuals listed under “Related Publi- cations” on page 165. Communication interfaces The PRIMERGY BX600 S2 basic unit has four slots on the back fo

Summary of the content on the page No. 11

Introduction Features 10 Gbit switch blade 10/2 – 10 internal 10 Gbit/s ports to the server blades – 2 external 10 Gbit/s ports with optional X2 transceiver modules for Fiber optical or CX4 copper cable I The 10 Gbit switch blade 10/2 only supports server blades, each equipped with a 10 GbE daughter card. All switch blades are hot-swappable. By installing two switch blades, redundant LAN connections can be provided for the server blades. ● Ethernet LAN Pass-Thru-Blade The Ethernet LAN Pass-T

Summary of the content on the page No. 12

Features Introduction KVM-Blade For administering the server blades, the PRIMERGY BX600 S2 basic unit offers a KVM blade, which allows the individual server blades to be connected to a console. – The standard KVM blade allows a monitor, PS2 keyboard and PS2 mouse to be connected for local administration of the server blades. – The adv. KVM blade offers the same functionality as the standard version of the KVM blade plus a LAN port for connecting a Web-based console. – The digital KVM blade o

Summary of the content on the page No. 13

Introduction Features Server Management Server management is implemented via the supplied ServerView software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers. PDA warns of system errors or overloading before they occur so that preventive measures can be taken. ServerView allows the management of all PRIMERGY servers in the network via a central console. Here ServerView supports the following functions: ● Remote startup (Wake On LAN) ● Temperature monito

Summary of the content on the page No. 14

Notational Conventions Introduction The flash EPROM program supplied with the Fujitsu Siemens utilities supports fast BIOS update. The two redundant and hot-swappable management blades with independent management LAN and COM ports ensure complete remote control. Together they facilitate remote diagnosis for system analysis, remote configuration and remote restart, should the operating system or hardware fail. 1.3 Notational Conventions The following notational conventions are used in this ma

Summary of the content on the page No. 15

Introduction Technical Data 1.4 Technical Data Electrical Data (single power supply unit) Rated voltage range 200 - 240 V Rated frequency 50 Hz - 60 Hz Max. rated current 230V / 11,6 A Max. active power 230 V / 2650 W Max. apparent power 2680 VA (230V) Thermal dissipation 2050 kJ/h Protection class I Electrical Data (basic unit without server blades) Power consumption 360 W Thermal dissipation 1300 kJ/h Compliance Standards Product safety and ergonomics IEC 60950 / EN 60950 UL 1950 3rd Edition,

Summary of the content on the page No. 16

Technical Data Introduction Europe ENEC Germany GS USA/Canada CSA / CSA US C Japan VCCI Mechanical Values Width 446 mm Installation depth 740 mm Height 307 mm oder 7 HE Weight max. 131.5 kg (depending on the configuration) 16 PRIMERGY BX600 S2 Basic Unit © cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: H:\windows\_projekte\Bxz\Betriebsanleitung\Version_Maerz-2007\Archiv\BX600S2_en\blade-us.k01

Summary of the content on the page No. 17

Introduction Technical Data Environmental Conditions Environment class 3K2 DIN IEC 721 section 3-3 Environment class 2K2 DIN IEC 721section 3-2 Temperature: Operation (3K2) 5 ºC .... 35 ºC Transport (2K2) -20 °C .... 60 °C Relative humidity 10%...85% Condensation during operation must be avoided. Noise Level Sound power level L (ISO 7779) 7.8 BA WAd Sound pressure level at bystander position ≤ 59 dB(A) (in the L (ISO 9296) standard configuration) pAm PRIMERGY BX600 S2 Basic Unit 17

Summary of the content on the page No. 18

© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: H:\windows\_projekte\Bxz\Betriebsanleitung\Version_Maerz-2007\Archiv\BX600S2_en\blade-us.k01

Summary of the content on the page No. 19

2 Overview: Basic Unit Installation Steps In this chapter you will find an overview of the steps necessary to install your BX600 S2 basic unit. Links guide you to sections where you can find more detailed information on the individual steps. Ê Before you begin, please read the chapter “Important Notes” beginning on page 21, especially the section “Notes on Safety”. Ê Unpack the system, check the contents of the package for visible transport damage, and check whether the delivery matches th

Summary of the content on the page No. 20

Overview: Basic Unit Installation Steps – Remote installation with ServerStart This installation method is recommended if a LAN connection and a DHCP server are available but the requirements for cloning are not satisfied. – Local installation with or without ServerStart Since the local installation is the least convenient installation method, it is only recommended if the requirements for remote installation or cloning are not satisfied. If you wish to install an operating system that is n


Alternative user manuals
# User manual Category Download
1 Fujitsu BX900 S1 User manual Server 23
2 Fujitsu 2000 User manual Server 1
3 Fujitsu CM71-00101-5E User manual Server 1
4 Fujitsu 5.0L10 User manual Server 1
5 Fujitsu 2000 SERIES User manual Server 1
6 Fujitsu Cloud Edition V3.1.0 User manual Server 0
7 Fujitsu C122-E180-01EN User manual Server 0
8 Fujitsu C120-E361-04EN User manual Server 2
9 Fujitsu M10-4S User manual Server 0
10 Fujitsu M10 User manual Server 1
11 Fujitsu M10-4 User manual Server 0
12 Fujitsu C122-H007-01EN User manual Server 0
13 Fujitsu J2X0-2273-01EN User manual Server 0
14 Fujitsu M8000 User manual Server 0
15 Fujitsu RX300 S2 User manual Server 25
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9