Dell POWEREDGE M905 user manual

User manual for the device Dell POWEREDGE M905

Device: Dell POWEREDGE M905
Category: Server
Manufacturer: Dell
Size: 7.25 MB
Added : 6/23/2013
Number of pages: 90
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dell POWEREDGE M905. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dell POWEREDGE M905.

For your convenience

If looking through the Dell POWEREDGE M905 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dell POWEREDGE M905 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dell POWEREDGE M905 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dell POWEREDGE M905 User manual - Online PDF
Advertisement
« Page 1 of 90 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dell POWEREDGE M905 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dell POWEREDGE M905. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Dell™ PowerEdge™
M905, M805, M605, and M600
Getting Started
With Your System
Guide de mise en route
Primeiros passos com o sistema
Procedimientos iniciales con el sistema

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Dell™ PowerEdge™ M905, M805, M605, and M600 Getting Started With Your System

Summary of the content on the page No. 4

Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death. ____________________ Information in this document is subject to change without notice. © 2008 Dell Inc. All rights reserved. Reproduction in any manner whatsoever

Summary of the content on the page No. 5

System Features This section describes the major hardware and software features of your system. It also provides information about other documents you may need when setting up your system and how to obtain technical assistance. System Enclosure Features The M1000e system enclosure (chassis) includes the following features: Scalability Features  Support for up to 16 half-height or 8 full-height blades (server modules).  Support for three layers of I/O fabric, selectable between combinations

Summary of the content on the page No. 6

Systems Management Features  A Chassis Management Controller (CMC), which provides several essential systems management features: – Enclosure-level power management and thermal management:  The CMC monitors system power requirements and supports the optional Dynamic Power Supply Engagement mode so that the CMC can enable or place power supplies in standby dynamically, depending on load and redundancy requirements, to improve power efficiency.  The CMC reports real-time power consumptio

Summary of the content on the page No. 7

The CMC has two Ethernet ports. "Gb1" is used to connect to the external management network. "Stack" allows CMCs in adjacent enclosures to be daisy-chained. A 24-port Ethernet switch provides internal 100-Mb communication with the blades, I/O modules, optional iKVM, and optional second, redundant CMC, and provides a 10/100/1000-Mb connection to the external management network. NOTE: The 24-port Ethernet switch is reserved for internal communication between the iDRAC on the blades to the C

Summary of the content on the page No. 8

Blade Features Performance Features PowerEdge M905 ™ ™  Four AMD Opteron 8000 Series dual-core or quad-core processors.  A minimum of 8 GB of 677 MHz DDR2 memory modules, upgradable to a maximum of 192 GB by installing pairs of 1-GB, 2-GB, 4-GB, or 8-GB modules in the 24 memory module sockets on the blade system board. The blade also supports memory sparing if eight or sixteen memory module sockets are populated with identical memory modules.  An SD (Secure Digital) card slot for embedde

Summary of the content on the page No. 9

PowerEdge M605  One or two AMD Opteron 2000 Series dual-core or quad-core processors.  A minimum of 1 GB of 677-MHz or 800-MHz DDR2 memory modules, upgradable to a maximum of 64 GB by installing pairs of 512-MB, 1-GB, 2-GB, 4-GB, or 8-GB modules in the eight memory module sockets on the blade system board. The blade also supports memory sparing. Common Features  The PowerEdge M805 and M905 blades support one or two 2.5 inch SAS hard drives.  The PowerEdge M600 and M605 blades support

Summary of the content on the page No. 10

The following software is included with your system:  A System Setup program for quickly viewing and changing system configuration information. For more information on this program, see "Using the System Setup Program" in your Hardware Owner’s Manual.  Enhanced security features, including a system password and a setup password, available through the System Setup program.  System diagnostics for evaluating system components and devices. For information about the system diagnostics, see "R

Summary of the content on the page No. 11

 Red Hat Enterprise Linux Server AS and ES (version 5) (ia32)  Red Hat Enterprise Linux Server AS, ES, and WS (version 5) and EM64T ® SUSE Linux Enterprise Server 9 (x86_64) with SP3 and EM64T  SUSE Linux Enterprise Server 10 (x86_64) and EM64T ® VMWare ESX 3.1  VMWare ESX 3.5 Other Information You May Need CAUTION: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document.  The Configura

Summary of the content on the page No. 12

 Updates are sometimes included with the system to describe changes to the system, software, and/or documentation. NOTE: Always check for updates on support.dell.com and read the updates first because they often supersede information in other documents.  Release notes or readme files may be included to provide last-minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians. Obtaining Technical Assistance If you do n

Summary of the content on the page No. 13

Install the System in a Rack Install the system in the rack once you have read the "Safety Instructions" located in the rack installation documentation for your system. See your rack installation documentation for instructions on installing your system in a rack. For power and cooling guidelines, see the rack capacity planner tool on www.dell.com. Install the Blades Beginning at the top, slide the modules into the enclosure from left to right. When the blade is securely installed, the handl

Summary of the content on the page No. 14

Connect the CMC and KVM Modules Connect the serial cable and network cable from the management system to the CMC module. If a second, optional CMC module is installed, connect it as well. (If your chassis was shipped with M805 or M905 blades pre-installed, the included CMC firmware will be version 1.2 or greater.) Connect the keyboard, mouse, and monitor to the optional iKVM module. Connect the System to Power Connect the system’s power cables to the system power supplies. NOTICE: To preven

Summary of the content on the page No. 15

Turn on the System Press the power button on the enclosure. The power indicator should light. Getting Started With Your System 13

Summary of the content on the page No. 16

Turn on the Blades Press the power button on each blade, or power on the blades using the systems management software. Complete the 0perating System Setup If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the Quick Installation Guide. Be sure the operating system is installed before installing hardware or software not purchased with the system. 14 Getting Started With Y

Summary of the content on the page No. 17

Technical Specifications Blade Specifications Processor Processor type PowerEdge M905 Four dual-core or quad-core AMD Opteron 8000 Series processors PowerEdge M805 Two dual-core or quad-core AMD Opteron 2000 Series processors PowerEdge M600 One or two dual-core or quad-core Intel Xeon processors PowerEdge M605 One or two dual-core or quad-core AMD Opteron 2000 Series processors Memory Architecture PowerEdge M600 FBD memory modules, rated for 677-MHz operation PowerEdge M905, M805, M605 DDR2

Summary of the content on the page No. 18

Memory Maximum RAM PowerEdge M905 192 GB PowerEdge M805 128 GB PowerEdge M600, M605 64 GB Drives Hard Drives PowerEdge M805, M905 One or two 2.5-inch SAS hard drives PowerEdge M600, M605 SATA configuration One or two 2.5-inch SATA hard drives SAS configuration One or two 2.5-inch SAS hard drives NOTE: SAS and SATA hard drives cannot be mixed within a M600 or M605 blade. Connectors External USB PowerEdge M805, M905 Three 4-pin, USB 2.0 compliant PowerEdge M600, M605 Two 4-pin, USB 2.0 complian

Summary of the content on the page No. 19

Video Controller Video type ATI RN50 video controller Video memory 32 MB Physical PowerEdge M905, M805 Height 38.5cm (15.2 in) Width 5 cm (2 in) Depth 48.6 cm (19.2 in) Weight (maximum configuration) 11.1 kg (24.5 lb) PowerEdge M605, M600 Height 18.9 cm (7.4 in) Width 5 cm (2 in) Depth 48.6 cm (19.2 in) Weight (maximum configuration) 5.2-6.4 kg (11.5-14.0 lb) Battery Blade battery CR 2032 3.0-V lithium ion coin cell System Enclosure Specifications Physical Height 44.0 cm (17.3 in) Width 44.7 cm

Summary of the content on the page No. 20

Power Supply Module AC/DC power supply (per power supply) Wattage 2360 W Connector NEMA C20 receptacle Heat dissipation 1205 BTU/hr. maximum Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less. System Voltage Requirements 200 - 240V, 16A, 3-Phase, 50 /60Hz 200 - 240V, 40.5A, Single Phase, 50 /60Hz Optional Avocent iKVM Module Rear externally accessible connectors USB Two 4


Alternative user manuals
# User manual Category Download
1 Dell 2450 User manual Server 5
2 Dell 750N. 755N User manual Server 1
3 Dell C6220 User manual Server 5
4 Dell 35XX User manual Server 1
5 Dell C5220 User manual Server 3
6 Dell 350 User manual Server 2
7 Dell 530F User manual Server 2
8 Dell 2950 User manual Server 14
9 Dell E600I User manual Server 0
10 Dell CX4 User manual Server 10
11 Dell E19S User manual Server 26
12 Dell R200 User manual Server 22
13 Dell MD3620F User manual Server 1
14 Dell MD3600F User manual Server 3
15 Dell R420 User manual Server 5
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9