Summary of the content on the page No. 1
Dell™ PowerEdge™
M1000e, M910, M905, M805,
M710HD, M710, M610x, M610,
M605, and M600
Getting Started
With Your System
Guide de mise en route
Primeiros passos com o sistema
Procedimientos iniciales con el sistema
Summary of the content on the page No. 2
Summary of the content on the page No. 3
Dell™ PowerEdge™ M1000e, M910, M905, M805, M710HD, M710, M610x, M610, M605, and M600 Getting Started With Your System Model BMX01, HHB Series, FHB Series
Summary of the content on the page No. 4
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. ____________________ Information in this document is subject to change without notice. © 2010 Dell Inc. All rights reserved. Reproduction of these materials in any manner w
Summary of the content on the page No. 5
Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. This section describes the steps required to set up your system for the first time. Unpack the System Unpack your system and identify each item. Installing the Rails and System in a Rack Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your enclosure. Getting Sta
Summary of the content on the page No. 6
Installing the Blades Beginning at the top, slide the modules into the enclosure from left to right. When the blade is securely installed, the handle returns to the closed position. Connecting the CMC and KVM Modules Connect the serial cable and network cable(s) from the management system to the CMC module. If a second, optional CMC module is installed, connect it as well. Connect the keyboard, mouse, and monitor to the optional iKVM module. 4 Getting Started With Your System
Summary of the content on the page No. 7
Connecting the System to Power Connect the system’s power cables to the system power supplies. CAUTION: To prevent the power cables from being disconnected accidentally, use the plastic clip on each power supply to secure the power cable to the power supply, and use the Velcro strap to secure the cable to the strain-relief bar. Plug the other end of the power cables into a power distribution unit (PDU). CAUTION: Do not plug the power cables directly into a power outlet; you must use a PDU.
Summary of the content on the page No. 8
Turning On the System Press the power button on the enclosure. The power indicator should light. NOTE: Once you have connected the system to the power supplies, there may be a minimal delay before you can turn on your system. Turning On the Blades Press the power button on each blade, or power on the blades using the systems management software. 6 Getting Started With Your System
Summary of the content on the page No. 9
Complete the Operating System Setup If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system. Supported Operating Systems Operating System M710HD M910 M905 M805 M710 M610 M610x M605 ® Citrix Xe
Summary of the content on the page No. 10
Operating System M710HD M910 M905 M805 M710 M610 M610x M605 Microsoft Windows Web Server 2008 (x64) Edition with SP2 Microsoft Windows Server 2008 R2 Standard, Enterprise, and Datacenter (x64) Editions Microsoft Windows Server 2003 Standard and Enterprise Editions Microsoft Windows Server 2003 Web Edition Microsoft Windows Server 2003 Standard Enterprise, and Web Editions with SP1 and later Microsoft Windows Server 2003 R2 Standard and Enterprise (x86) Edition
Summary of the content on the page No. 11
Operating System M710HD M910 M905 M805 M710 M610 M610x M605 Red Hat Enterprise Linux AS and ES (version 4.8) (x86) Red Hat Enterprise Linux AS and ES (version 4.8) (x86_64) Red Hat Enterprise Linux (version 5.0) (x86) Red Hat Enterprise Linux (version 5.0) (x86_64) Red Hat Enterprise Linux (version 5.2) (x86) Red Hat Enterprise Linux (version 5.5) (x86) Red Hat Enterprise Linux (version 5.5) (x86_64) ® SUSE Linux Enterprise Server 9 (x86_64) SP3 SUSE
Summary of the content on the page No. 12
Other Information You May Need WARNING: Before performing the following procedure, review the safety instructions that came with the system. The Configuration Guide provides information on configuring the system enclosure and the blades. Rack Installation Instructions included with your rack solution describes how to install your system into a rack. The Hardware Owner’s Manual provides information about system features and describes how to troubleshoot the system and install or replac
Summary of the content on the page No. 13
Technical Specifications Blade Specifications Processor Processor type ® ® PowerEdge M910 Two or four Intel Xeon 7000 series processors (up to eight-core processors) ® ® PowerEdge M905 Four dual- or quad-core AMD Opteron 8000 series processors PowerEdge M805 Two dual- or quad-core AMD Opteron 2000 series processors PowerEdge M710HD, One or two dual-, quad-, or six-core Intel Xeon 5000 M710, M610, M610x series processors PowerEdge M605 One or two dual- or quad-core AMD Opteron 2000 series p
Summary of the content on the page No. 14
Memory (continued) Memory module sockets PowerEdge M910 32 240-pin sockets PowerEdge M905 24 240-pin sockets PowerEdge M805 16 240-pin sockets PowerEdge M710HD 18 240-pin sockets PowerEdge M710 18 240-pin sockets PowerEdge M610x, M610 12 240-pin sockets PowerEdge M605, M600 Eight 240-pin sockets Memory module capacities PowerEdge M910 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs PowerEdge M905, M805, 1 GB, 2 GB, 4 GB, and 8 GB PowerEdge M710HD 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs and LV DIMMs Po
Summary of the content on the page No. 15
Memory (continued) Maximum RAM PowerEdge M910 512 GB PowerEdge M905 192 GB PowerEdge M805 128 GB PowerEdge M710HD 144 GB (dual-rank DIMMs) or 192 GB (quad-rank DIMMs) PowerEdge M710 192 GB (12 16-GB RDIMMs); 36 GB (18 2-GB UDIMMs) PowerEdge M610, M610x 192 GB (12 16-GB RDIMMs); 24 GB (12 2-GB UDIMMs) PowerEdge M600, M605 64 GB Drives Hard Drives PowerEdge M910 Up to two 2.5-inch SAS hard-disk drives support through value RAID or performance RAID storage card. or Up to two 2.5-inch SSD hard-d
Summary of the content on the page No. 16
Drives (continued) PowerEdge M600, One 2.5-inch SATA hard-disk drive support through M610x, M610 non-RAID, value RAID, or performance RAID storage card. or Two 2.5-inch SATA hard-disk drives support through value RAID or performance RAID storage card. or One solid-state disk (SSD) hard drive support through non-RAID storage card. or Up to two SAS hard-disk drives support through value RAID or performance RAID storage card. PowerEdge M605 Up to two SATA hard-disk drives support through valu
Summary of the content on the page No. 17
Connectors (continued) Internal Internal Secure Digital One optional flash memory card slot (SD) module (PowerEdge with the internal SD module. M910, M805, M905, M710HD, M710, M610x, M610) Internal Secure Digital One optional vFlash memory card slot for (SD) vFlash module use with the iDRAC Enterprise support. (PowerEdge M910, M710HD, M710, M610x, M610) USB key (PowerEdge One internal USB key connector. M910, M710HD, M710, M610x, M610) PCIe Expansion Solution PowerEdge M610x Supports two
Summary of the content on the page No. 18
Mezzanine Cards (continued) PowerEdge M610x, M610 Up to two PCIe Gen 2 x8 mezzanine card slots, supporting dual-port Gb Ethernet, 10 Gb Ethernet, FC8 or FC4 (M610 only) Fibre Channel, or 4x DDR Infiniband mezzanine cards. PowerEdge M605, M600 Up to two PCIe x8 mezzanine card slots, supporting dual-port Gb Ethernet, 10 Gb Ethernet, FC8 or FC4 Fibre Channel, or 4x DDR Infiniband mezzanine cards. Embedded Ethernet Controllers PowerEdge M910, M905, Four Ethernet ports with TOE and iSCSI boot
Summary of the content on the page No. 19
Physical (continued) PowerEdge M905, M805, M710, M610x Height 38.5cm (15.2 in) Width 5 cm (2 in) Depth 48.6 cm (19.2 in) Weight (maximum 11.1 kg (24.5 lb) configuration) PowerEdge M710HD Height 18.9 cm (7.4 in) Width 5 cm (2 in) Depth 48.6 cm (19.2 in) Weight (maximum 7.4 kg (16.3 lb) configuration) PowerEdge M605, M600 Height 18.9 cm (7.4 in) Width 5 cm (2 in) Depth 48.6 cm (19.2 in) Weight (maximum 5.2–6.4 kg (11.5–14.0 lb) configuration) Battery NVRAM backup battery CR 2032 3.0-V lithium co
Summary of the content on the page No. 20
System Enclosure Specifications Physical Height 44.0 cm (17.3 in) Width 44.7 cm (17.6 in) Depth 75.5 cm (29.7 in) Weight (maximum 178.3 kg (392.2 lb) configuration) Weight (empty) 44.6 kg (98.1 lb) Power Supply Module AC/DC power supply (per power supply) Wattage 2360 W and 2700 W Connector IEC C20 Heat dissipation 1205 BTU/hr. maximum Maximum inrush Under typical line conditions and over the entire current system ambient operating range, the inrush current may reach 55 A per power supply for