Black Box Modbus Hardened Serial user manual

User manual for the device Black Box Modbus Hardened Serial

Device: Black Box Modbus Hardened Serial
Category: Server
Manufacturer: Black Box
Size: 25.63 MB
Added : 11/5/2014
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Black Box Modbus Hardened Serial. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Black Box Modbus Hardened Serial.

For your convenience

If looking through the Black Box Modbus Hardened Serial user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Black Box Modbus Hardened Serial on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Black Box Modbus Hardened Serial to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Black Box Modbus Hardened Serial User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Black Box Modbus Hardened Serial but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Black Box Modbus Hardened Serial. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

LES431A
Modbus Hardened Serial Server
Connect Modbus networks (RS-232, RS-422,
®
BL A CK BOX
or RS-485) to Ethernet networks, allowing
the Modbus network to become a node
on the network.
Access the Modbus network over a LAN/WAN using direct IP mode
connections.
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
Customer
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Support
Mailing address: Black Box Corporation,

Summary of the content on the page No. 2

Trademarks Used in this Manual Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Firefox is a registered trademark of Mozilla Foundation. Internet Explorer, Windows, and Windows Vista are registered trademarks of Microsoft Corporation. UL is a registered trademark of Underwriters Laboratories. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. We‘re here to help! If you h

Summary of the content on the page No. 3

FCC and IC RFI Statements Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15

Summary of the content on the page No. 4

NOM Statement Instrucciones de Seguridad (Normas Oficiales Mexicanas Electrical Safety Statement) 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. T odas las instrucciones de operación y uso deben ser seguidas. 5. El aparato

Summary of the content on the page No. 5

Table of Contents Table of Contents 1. Specifications .........................................................................................................................................................................6 2. Overview ...............................................................................................................................................................................9 2.1 Introduction ...............................................................

Summary of the content on the page No. 6

Chapter 1: Specifications 1. Specifications General Specifications ® Approvals FCC Part 15, Class A, CE, NEMA TS2, UL Class 1, Division 2, Groups A, B, C, and D ® ® Compatible Windows XP (32/64 bit), 2003 Server (32/64 bit), Windows Vista (32/64 bit), Operating Systems 2008 Server (32/64 bit), Windows 7 (32/64 bit) Configuration Via serial port using Modbus Hardened Serial Server Software, via network using Modbus Hardened Serial ® Options Server Software with an Ethernet connection or a stan

Summary of the content on the page No. 7

Chapter 1: Specifications Network Specifications Character Count 0 to 65535 Connection Modes Server, Client Memory Serial: 8 KB per port; Network memory: 4 KB Firmware Upgrade Via serial, Ethernet, or auto Web search IP Port Addresses 5300: heartbeat and configuration setting in TCP mode; 8888: LES431A update Network LAN: 10-/100-Mbps auto-detecting 10BASE-T and 100BASE-TX Communications Network Physical Ethernet: IEEE 802.3 autodetecting and auto MDI/MDI-X 10BASE-T and 100BASE-TX Layer Standa

Summary of the content on the page No. 8

Chapter 1: Specifications Dimensional Diagrams Figure 1-1. Dimensional diagram of a LES431A Modbus Hardened Serial Server. Page 8 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com

Summary of the content on the page No. 9

Chapter 2: Overview 2. Overview 2.1 Introduction The 1-Port Modbus Hardened Serial Server connects Modbus networks (RS-232, RS-422, or RS-485) to Ethernet networks, allowing the Modbus network to become a node on the network. The serial port can be accessed over a LAN/WAN using Direct IP Mode connections. Modbus Hardened Serial Servers use 10BASE-T or 100BASE-TX copper network media. The servers are built for use in industrial environments and feature an IP30 approved slim-line DIN-rail-moun

Summary of the content on the page No. 10

Chapter 2: Overview 2.4 Hardware Description 1-Port Modbus Hardened Serial Server (LES431A) Figures 2-1 and 2-2 show the front, back, and top panels of the LES431A. Table 2-2 describes its components. 4 7 5 6 1 2 3 Figure 2-1. LES431A front and back panels. 4 8 Figure 2-2. LES431A top panel. Page 10 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com

Summary of the content on the page No. 11

Chapter 2: Overview Table 2-2. LES431A components. Number in Figure 2-1 or 2-2 Component Description 1 (1) RJ-45 connector Connects a standard Ethernet network drop using a straight-through RJ-45 male Ethernet cable. 2 (1) 5-position terminal block connector Connects to an RS-422 or RS-485 serial device when the DB9 M (RS-232) connector is disabled. 3 (1) DB9 male connector Connects to an RS-232 serial device when the 5-position terminal block (RS-422/RS-485) is disabled. 4 (1) 2-wire terminal

Summary of the content on the page No. 12

Chapter 3: Installation and Initial Setup 3. Installation and Initial Setup NOTE: In this section, devices to be connected to the Modbus Hardened Serial Server’s serial connections are simply referred to as the “Modbus network.” 3.1 Connecting the Power Supply Connect a DC power supply to the power terminals on the side of the Modbus Hardened Serial Server. Polarity of the wires is indicated on the label on the side of the Modbus Hardened Serial Server. Acceptable voltages are between 10 VDC

Summary of the content on the page No. 13

Chapter 3: Installation and Initial Setup If you select RS-232 mode when you configure the Modbus Hardened Serial Server, you must connect the Modbus serial network to the Modbus Hardened Serial Server via a serial cable. The LES431A is a DTE. If the Modbus network is a DTE, use a null- modem (crossover) cable. If the Modbus network is a DCE, use a straight-through cable. DTE and DCE ports are complementary; the output signals on a DTE port are inputs to a DCE port, and output signals on a DCE

Summary of the content on the page No. 14

Chapter 3: Installation and Initial Setup 3.4.1 Installing Modbus Hardened Serial Server Configuration Software Step 1: Download the Modbus Configuration Manager Software from ftp://ftp.blackbox.com. Double-click on the executable file. The file name is Modbus Hardened Serial Server Manager Vx.x.x. a. The following screen will be displayed on your computer. Figure 3-3. Modbus Hardened Serial Server Manager Installation Welcome screen. b. Click “Next.” The License Agreement Screen will be displ

Summary of the content on the page No. 15

Chapter 3: Installation and Initial Setup c. Click “Next.” The User Information Screen will be displayed on your computer. Enter your name and organization (optional) and select if the software will be accessible to your account or anyone who uses the computer. Figure 3-5. User information screen. d. Click “Next.” The Destination Folder Screen will be displayed on your computer. The default directory is: C:\Program Files\Black Box\Modbus Hardened Serial Server\ If desired, you can select anot

Summary of the content on the page No. 16

Chapter 3: Installation and Initial Setup Figure 3-7. Ready to Install Application screen. f. Click “Next.” The software will begin installing. Figure 3-8. Software Installing screen. Page 16 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com

Summary of the content on the page No. 17

Chapter 3: Installation and Initial Setup g. After the installation is complete, an information screen will be displayed containing contact information and release notes. Click “Next.” Figure 3-9. Information screen. h. The Installation Complete screen will be displayed on your computer. Click “Finish” to finish the installation. Figure 3-10. Installation Complete screen. 3.4.2 Configuring the Modbus Hardened Serial Server via the Network Connection To configure via the network, you can use

Summary of the content on the page No. 18

Chapter 3: Installation and Initial Setup To open Modbus Hardened Serial Server Configuration Manager: 1. From the Desktop, click Start—>Programs—>Modbus Hardened Serial Server Manager. An alternate method is to double-click the shortcut installed on the desktop. Figure 3-11. Opening Modbus Hardened Serial Server Configuration Manager. Figure 3-12. Modbus Hardened Serial Server Configuration Manager Shortcut Icon. Page 18 724-746-5500 | blackbox.com 724-746-5500 | blackbox.com

Summary of the content on the page No. 19

Chapter 3: Installation and Initial Setup 2. The Modbus Hardened Serial Server Configuration Manager Device Discovery window appears. Figure 3-13. Modbus Hardened Serial Server Configuration Manager Discovery window. 3. I f you do not know the IP address, check the “Network” and “I don’t know the IP address of this device” selections and press the “Connect Button.” The software will discover any LES431A Gateways on the network. The configuration manager screen will be displayed on your compute

Summary of the content on the page No. 20

Chapter 3: Installation and Initial Setup 5. The default password is no password. Click the “Login” button. The “General” Settings screen will be displayed on your computer. 6. See the Modbus Hardened Serial Server Manager Settings Screen Overview in Figure 3-15. Figure 3-15. Settings Screen Overview. A. This area shows Modbus Hardened Serial Servers available on the network. B. This area is used to skip directly to the specific configuration screen you need to access. An alternate method of


Alternative user manuals
# User manual Category Download
1 Black Box LES1216A-R2 User manual Server 17
2 Black Box EME1DC16 User manual Server 0
3 Black Box 5000 User manual Server 1
4 Black Box LES1132A User manual Server 1
5 Black Box LES1248A-R2 User manual Server 13
6 Black Box 26589 User manual Server 0
7 Black Box LES1116A User manual Server 4
8 Black Box LES1208A-R2 User manual Server 1
9 Black Box EME144A-R2 User manual Server 1
10 Black Box LES1432A User manual Server 0
11 Black Box LES1408A User manual Server 0
12 Black Box LES431A User manual Server 7
13 Black Box LES1332A User manual Server 1
14 Black Box LES144BA User manual Server 0
15 Black Box LES1416A User manual Server 0
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9