Summary of the content on the page No. 1
SCC-C4253P
SCC-C4353P
SCC-C4255P
SCC-C4355P
Power Zoom Camera
User Manual
imagine the possibilities
Thanks you for purchasing this Samsung product.
To receive a more complete service, please visit
our website
www.samsungsecurity.com
EU ENGLISH.indd 1 2009-9-10 13:53:44
Summary of the content on the page No. 2
overview CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. WARNING To reduce the risk of fire or elect
Summary of the content on the page No. 3
English 7. Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire or electric shock. 8. If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the power source and contact the service center. Continued use in such a condition may cause fire or electric shock. 9. If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way. (SAMSUNG is no
Summary of the content on the page No. 4
overview FCC STATEmENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : 1) This device may not cause harmful interference, and 2) This device must accept any interference received including interference that may cause undesired operation. Caution This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection
Summary of the content on the page No. 5
English ImPORTANT SAFETy INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the po
Summary of the content on the page No. 6
overview CONTENTS 5 Important Safety Instructions OvERvIEW 6 Contents 7 Features 8 What’s Included 2 8 At a Glance 12 Preparing Installation INSTALLATION & 12 Installation CONNECTION 12 15 Main Menu SETUP 16 Profile 18 Camera Set 27 Intelligent Video 15 29 Privacy Zone 30 Preset 31 Other Set 32 Communication 32 System Info 33 Language 34 Shortcut Keys APPENDIx 35 Specifications 34 _ overview EU ENGLISH.indd 6 2009-9-10 13:53:45
Summary of the content on the page No. 7
English FEATURES With the state-of-the-art digital signal processing technology, full digital image processing and special algorithm of 600-line high resolution implemented. High Sensitivity: It implements images of high sensitivity using the up-to-date Super-HAD IT CCD(SCC-C4253P/C4353P)/ExView-HAD PS CCD(SCC-C4255P/ C4355P). VPS(Virtual Progressive Scan): This is an advanced technology that reproduces a sharp progressive image. This is appropriate to high quality recording and file t
Summary of the content on the page No. 8
overview WHAT’S INCLUDED Please check if your camera and accessories are all included in the product package. Camera Holder Camera (Mount Adaptor) User's Manual 2 Screws AT A GLANCE SIDE vIEW Mount Adapter Fixing Grooves Camera Lens Wipe out a dirty surface of the lens softly with a lens tissue or cloth to which you M have applied ethanol. _ overview EU ENGLISH.indd 8 2009-9-10 13:53:45
Summary of the content on the page No. 9
English � � � � Rear Panel � � SCC-C4353P SCC-C4355P � � � � � � � � � � � � � � � � � � SCC-C4253P SCC-C4255P � � � � � � � � � � � � � � � � � � Input/Output Connector This connector has input and output ports for RS-485 control signals, DAY/NIGHT switching, and alarm output signals. � � � � � � SCC-C4255P/C4355P SCC-C4253P/C4353P English _ EU ENGLISH.indd 9 2009-9-10 13:53:47
Summary of the content on the page No. 10
overview 1. ALARM OUT Alarm out jack for motion detection. (Open Collector, On Gnd) 2. GND Grounding jack. 3. TRIGGER IN (SCC-C4255P/C4355P) Displays the current still image when it receives the Trigger signal. (Normal Open Type) 4.5.6 FOCUS, COM, ZOOM This port is used for ZOOM/FOCUS, MENU CONTROL, HOME RETURN, and ONEAF by using an external controller. Depending on the input condition, 4 modes, A, B, C, and D are available. (SPECIAL - CTRL TYPE) (Operation Voltage Range : +3V~+13V, -3V~
Summary of the content on the page No. 11
English * 2 : For short voltage supply during MENU OFF, executes ONEAF and for more than 2 second * 3 : For more than 2 second long voltage supply, moves to the PRESET 0(HOME) position. 7. 5V OUT Power supply jack for RS-485 JIG. Use within typical DC +5V 100mA. 8. DAY/NIGHT IN This is a function to receive the external DAY/NIGHT signal from the sensor(option) and convert the signal into BW. 9. RS-485 DATA- Jack for connection to RS-485 DATA- signal line. 10. RS-485 DATA+ Jack for conne
Summary of the content on the page No. 12
installation & connection PREPARING INSTALLATION To install and use the camera, first prepare the following cables. Power Adapter Cable (sold separately) The requirements for the power adapter, which connects to the camera’s POWER IN terminal, are as follows: - SCC-C4253P/C4255P : DC 12V 600mA - SCC-C4353P/C4355P: A C 24V 300mA DC 12V 600mA video Cable(sold separately) Use a BNC cable, such as the one shown below, to connect the camera’s VIDEO OUT to the monitor. INS
Summary of the content on the page No. 13
English 1 2 3 4 5 6 7 8 CZOOM OM FOCUS 1. 2. GND ALARAM OUT 5. 6. 3. TRIGGER IN 7. 5V OUT 4. 8. DAY/NIGHT IN Video In Terminal of Monitor Rear Surface BNC cable(not included) Video Out Terminal 3. Plug in the power adapter(not inlcluded). Use a “minus” screwdriver to connect one part of the power adapter, which consists of two lines, to the POWER terminal of the camera as follows : +12V GND SCC-C4253(P)/C4255(P) SCC-C4353(P)/C4355(P) English _1 EU ENGLISH.indd 13 2009-9-10 13:53:48
Summary of the content on the page No. 14
installation & connection 4. Determine the type of power supply and set the POWER SELECTION switch accordingly. Next, plug the power adapter into a wall outlet. 5. If the camera operates normally, the following screen will be displayed for 5 seconds and then disappears. TYPE 4_ZOM_WDR_P PROTOCOL SAMSUNG ADDRESS 0 COMM.TYPE RS485,HALF BAUD RATE 9600 CAMERA VER. V1.00_090817 LENS OK 6. The requirements for RS485 control is as follows : - Signaling Speed: 9600 bps - Data Bit : 8 bits - St
Summary of the content on the page No. 15
English setup Using OSD icons _+ : If these icons appear in the left and right corner of a menu item, you can use them move to the previous or next menu. (EXIT): Exits the menu setup screen. Before exiting the setup screen, select to save your settings to the whole menus, or to cancel them. (RET): Saves your settings and returns to the previous screen. (HOME): Returns to the main menu. (SAVE): Use this icon if you want to save your settings after you specified the
Summary of the content on the page No. 16
setup COmmUNICATION Configures the settings pertaining to RS-485 communication. SySTEm INFO Shows the system information such as the camera version or communication settings. LANGUAGE Select a preferred one from the supported languages. PROFILE You can select one from the pre-determined configurations as appropriate to your specific camera installation environment. Your selection on each item in PROFILE will affect all other settings of the camera. STANDARD Automatically optimizes the
Summary of the content on the page No. 17
English CAmERA SETUP mENU STANDARD ITS BACKLIGHT DAy/NIGHT GAmING Parent menu Sub-menus vPS OFF ON OFF OFF OFF ALC ALC ALC ALC ALC ALC - - - - - LEvEL 0 0 0 0 0 BACKLIGHT OFF OFF WDR OFF OFF IRIS WDR - - - - - WEIGHT Custom Setting Custom Setting MEDIUM Custom Setting Custom Setting WDR LEvEL Custom Setting Custom Setting 0 Custom Setting Custom Setting WHITE BAL Custom Setting Custom Setting Custom Setting Custom Setting Custom Setting (F.FAST) (F.FAST) (F.FAST) NORM SLOW mOTION --- --- --- ME
Summary of the content on the page No. 18
setup CAmERA SET You can configure the general settings of the camera module. 1. Select - . CAMERA SET The Camera Setup menu appears. CAMERA ID OFF VPS OFF 2. Change the settings as necessary, or select IRIS ALC an item to check. MOTION (F.FAST) --- DNR MID SHUTTER (OFF) --- SENS-UP AUTO X4 FLICKERLESS OFF XDR MID CAmERA ID Provide the ID and location for a camera that displays on the screen. 1. Select - . CAMERA ID ABCDEFGHIJKLMNOPQRST
Summary of the content on the page No. 19
English IRIS The IRIS menu is useful if you set to adjust the ALC intensity of radiation incoming to the camera. LEVEL [ 00] ----I---- BACKLIGHT BLC ALC : Adjust the open and close of the iris. AREA USER - LEVEL : Select an overall brightness level. - BLC : With set to , you can specify the BLC area. With AREA set to , you can specify the position and size. - WDR : If you set < BACKLIGHT> to ALC , you will see a menu where you [
Summary of the content on the page No. 20
setup AGC With this, you can adjust the AGC level of a CAMERA SET camera. CAMERA ID OFF With AGC active, if the signal strength falls VPS OFF below the standard level, AGC will amplify the IRIS ALC video signal to automatically improve the AGC (VERY HIGH) --- DNR MID sensitivity. SHUTTER OFF If is set to or SENS-UP OFF mode, the menu will switch to FLICKERLESS OFF XDR MID . With the USER ( ) submenu selected, press [ENTER] to display the corresp