Summary of the content on the page No. 1
INSTALLATION/OPERATION
®
ES30PC/ES31PC Esprit
®
with Pressurized IOC
U.S. Patent D-472.260
C311M-L (1/05)
Summary of the content on the page No. 2
CONTENTS Section Page IMPORTANT SAFETY INSTRUCTIONS ............................................................................................................................................................................... 5 DESCRIPTION ..................................................................................................................................................................................................................... 6 MODELS ...................................
Summary of the content on the page No. 3
GAIN/AGC ................................................................................................................................................................................................................ 34 IR FILTER MODE (MODELS ES30PCBW18/ES31PCBW18 ONLY) ............................................................................................................................. 35 LIMIT STOPS .......................................................................................
Summary of the content on the page No. 4
4 C311M-L (1/05)
Summary of the content on the page No. 5
IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8. Use only with the cart, stand, tripod, bracket,
Summary of the content on the page No. 6
DESCRIPTION The ES30PC/ES31PC Esprit Series is designed to protect camera optics and electronics from moisture and airborne contaminants. The system features a receiver, pan and tilt, enclosure, and a pressurized integrated optics cartridge (IOC). The integrated optics cartridge packages an auto focus camera, lens, heater, and sensors in a small, self-contained unit pressurized to 10 psig with dry nitrogen. MODELS ES30PC16 Standard resolution, color camera with 160X zoom (16X optical zoom and 10
Summary of the content on the page No. 7
INSTALLATION ® When installing the ES30PC/ES31PC Esprit system, allow for sufficient clearance between the top of the unit and overhead obstructions. This will prevent interference when the enclosure is driven to its maximum elevation of 33 degrees. ! " LOOSEN TRANSFORMER PHILLIPS MODULE SCREWS Remove
Summary of the content on the page No. 8
120/230 VOLTAGE SELECTOR SWITCH Route the wires and cables through the center of the Esprit mount. Reinstall the transformer module into the base. The transformer module can be positioned in the mount base in only one orientation. ES30PC-5/ES31PC-5 Models Only – Set the 120/230 voltage selector switch on the transformer to the appropriate voltage. Connect wires and cables. a. Connect to power. Use the two supplied clamp connectors to connect the AC line and neutral. 120/230 VAC 24 VAC Blac
Summary of the content on the page No. 9
Turn on the power. If the red LED lights, turn off the power and proceed to the next step. If the red LED does not light, refer to the Troubleshooting section. Plug the male Esprit system connector, located on the bottom of the pan and tilt, into the female Esprit system connector located on the transformer module. Align the pan and tilt part number with the alignment label of the base and then attach the pan and tilt to the base with three 1/4-20 nuts and washers (supplied). PART NUMBER MA
Summary of the content on the page No. 10
TXB SERIES TRANSLATOR BOARD INSTALLATION (OPTIONAL) Pelco’s TXB Series allows controllers from other companies to communicate with the Esprit system. To install a TXB Series board, remove the left cover of the pan and tilt. Once the cover is removed, refer to the manual supplied with the translator board to complete the installation. HOW TO REMOVE THE PAN AND TILT COVER 1. Unscrew the Phillips head screw located on the left cover of the pan and tilt. 2. Remove cover and place to the side. 10 C31
Summary of the content on the page No. 11
HOW TO REINSTALL THE PAN AND TILT COVER The pan and tilt covers must be properly seated and have a tight seal all the way around when installed. To reinstall the pan and tilt cover, do the following: 1. Properly position the cover and slide it into place. The sides of the cover must fit under the front and back rain guards of the pan and tilt, and the top of the cover must seat against the lip of the top gasket. 2. Apply pressure and push the top of the cover down to align the fastener holes. 3.
Summary of the content on the page No. 12
OPERATION POWER-UP DISPLAY When the system is powered up, the selected protocol, revision number, and other information is displayed on the monitor. For example, the screen might show the following information: ESPRIT 16X IOC 2.00 CONFIGURE DONE The information displayed depends on the selected protocol (C, D, or P) and the menu selection for power- up mode. (Refer to the Power-Up Mode in the Programming section). D Address 1 P Address 2 Comm 2400, N, 8, 1 The information remains on the monitor
Summary of the content on the page No. 13
PRESSURIZED INTEGRATED OPTICS CARTRIDGE The pressurized IOC houses an auto focus camera, lens, heater, and sensors in a self-contained, sealed unit. Dry nitrogen pressurized to 10 psig controls the environment inside the cartridge, eliminating internal condensation and corrosion. Sensors strategically placed inside the pressurized IOC continually monitor pressure, temperature, and relative humidity. If internal conditions reach unacceptable levels, an alert label appears on the screen describing
Summary of the content on the page No. 14
CURRENT READING MENU IOC Internal Reading Temperature 37 C 98 F Dewpoint 08 C 46 F Pressure 10.30 psig 0.71 bar Refresh Exit The Current Reading menu displays the existing status of temperature, pressure, and dewpoint inside the integrated optics cartridge. An asterisk displayed to the left of a menu item denotes that an alert condition exists. Due to the heat emitted from the electronics of the camera, normal temperature operating range is approximately 95°F. PAN AND TILT FUNCTIONS Controller
Summary of the content on the page No. 15
ZONES A zone is a programmed pan area with set boundaries and identifying label. The Esprit system has a maximum of eight zones, each with a 20-character label. Zones can be programmed to blank video when the camera pans into the zone area. If a zone is blanked, the system displays the message, VIDEO BLANK. (Refer to Zone Blank in the Programming section for instructions.) PATTERNS The Esprit system can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.5, or 3
Summary of the content on the page No. 16
PROGRAMMING – ES30PC16/ES31PC16 1. Access main menu (preset 95). Gain/AGC Menu 2. Make main menu selections. Gain Limit 27 Joystick: Move up or down to position cursor or Exit to toggle between selections. Iris Open: Enter. Camera Menu Iris Close: Cancel. Backlight comp Off Zoom limit x- - Reset camera MAIN MENU Auto Iris Menu Next Exit Auto-iris mode Auto Auto-iris level 66 * Auto-iris peak 8 Line Sync Menu Exit
Summary of the content on the page No. 17
PROGRAMMING – ES30PC22/ES31PC22 1. Access main menu (preset 95). Gain/AGC Menu 2. Make main menu selections. Gain Limit 7 Joystick: Move up or down to position cursor or Exit to toggle between selections. Iris Open: Enter. Camera Menu Iris Close: Cancel. Backlight comp Off Zoom limit x- - Reset camera MAIN MENU Auto Iris Menu Next Exit Auto-iris mode Auto Auto-iris level 66 * Auto-iris peak 16 Line Sync Menu Exit
Summary of the content on the page No. 18
PROGRAMMING – ES30PCBW18/ES31PCBW18 1. Access main menu (preset 95). Gain/AGC Menu 2. Make main menu selections. Gain Limit 28 Joystick: Move up or down to position cursor or Exit to toggle between selections. Iris Open: Enter. Camera Menu IR Filter Menu Iris Close: Cancel. Backlight comp Off IR Filter mode Auto Zoom limit x72 Auto IR Level Dusk Reset camera Exit MAIN MENU Auto Iris Menu Next Exit Auto-iris mode Auto Auto-iris level 91
Summary of the content on the page No. 19
PROGRAMMING ACCESSING MAIN MENU (PRESET 95) You can call up the main menu on your monitor by programming (setting or creating) preset 95 (28 if in 32-preset mode). Programming preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for programming preset 95 are given below for various Pelco controllers. CM6700 1. Enter the number of the camera and press the CAM key. 2. Enter 95 and hold the PRESET key for two seconds. 3. In the Edit Preset menu, a
Summary of the content on the page No. 20
ACK ACT (ACKNOWLEDGE ACTION) MAIN MENU Alert Menu Repeat Constant Disp Pos Top Right ACK Act Always On Alert Reset Exit ACK Alert Exit If an enivornmental condition inside of the IOC goes outside of the factory set limits (such as “Low Pressure”) then select ACK Alert to activate the alert label behavior. Program ACK Act to establish alert label behavior after alert acknowledgement. The following acknowledge