INSTALLATION
EH1512 Series
Enclosures
EH1512 Enclosure with EM1512 Mount
C3453M-C (5/09)
Summary of the content on the page No. 2
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Models . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 3
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the pola
Summary of the content on the page No. 4
Description The EH1512 Series indoor/outdoor enclosures are designed for use with small- to medium-sized analog and IP cameras. They will accommodate both fixed and variable focal length lenses (with or without auto-iris operation). They can be wall mounted using either Pelco’s EM1512 (feedthrough wall mount) or any light to medium duty mount. The tethered, removable enclosure lid provides easy access during installation and when camera and lens adjustments are necessary. Power and video cabl
Summary of the content on the page No. 5
OPTIONAL ACCESSORIES Blower Kit EH1512-1BKIT Continuous duty, 120 VAC, 1 W, 1.45 cfm EH1512-2BKIT Continuous duty, 24 VAC, 1 W, 1.45 cfm EH1512-3BKIT Continuous duty, 230 VAC, 1 W, 1.45 cfm Heater/Blower Kit EH1512-1HBKIT 120 VAC, 11 W, 1.45 cfm EH1512-2HBKIT 24 VAC, 11 W, 1.45 cfm EH1512-3HBKIT 230 VAC, 11 W, 1.45 cfm NOTE: Heaters are thermostatically controlled to turn on at 50°F (10°C) and turn off at 80°F (27°C). The blower operates continuously. Sun Shroud SS1512 Marine Kit EH-MKIT (requi
Summary of the content on the page No. 6
PACKAGE CONTENTS NOTE: A metric Allen wrench (5 mm) is required for installation but is not included. A Phillips screwdriver, flat head screwdriver, or 1/4-inch nut driver is needed for the EH1512-1 and EH1512-3 only. The Allen wrench is needed to open and close the enclosure and to secure the enclosure to all mounts. It is also needed to secure the pan/tilt (swivel head) on the EM1512 mount. The following items are supplied: Qty Description 1 EH1512 Series enclosure 1 Screw, 1/4-20 x 3/8-inc
Summary of the content on the page No. 7
Installation INSTALLING THE OPTIONAL SECURITY KIT The optional security kit (EH-SKIT) contains three tamper-resistant screws and a 1/8-inch hollow screwdriver bit. To install the security kit: 1. Use a 5-mm Allen wrench (not supplied) to remove the three 10-24 x 0.75-inch hex head screws (factory installed) that are located on the enclosure base. (Refer to Figure 2.) 2. Insert the three tamper-resistant screws in the bottom of the enclosure. 3. Tighten the screws using the 1/8-inch hollow scre
Summary of the content on the page No. 8
3. Remove the camera sled from the enclosure rail (refer to Figure 3). a. Squeeze the two plastic tabs (located near the front window) that hold the camera sled in place. b. Pull up and slide the sled forward. c. Remove the sled. Figure 3. Removing the Sled 4. Remove the parts bag. This includes the screws, split washers, glands, and nuts. 5. Remove the glands and nuts from the parts bag. 6. Wire the enclosure: � Without conduit (for example, the EM1512 mount): Install and tighten the glands an
Summary of the content on the page No. 9
8. (EM1512 mount only) Attach the mount to the wall: a. Use the mount as a template to mark and drill holes in the mounting surface. b. Pull the video and power cables from the wall through the mount. If wiring with conduit, use a step drill to drill a 0.875 inches (2.22 cm) hole in one of the three knockout locations for 1/2-inch conduit. (Knockouts are indicated on the side and bottom of the mount arm.) Refer to Table B on page 11 to determine the size of the power wire needed. Refer to Tabl
Summary of the content on the page No. 10
17. Adjust the camera focal length and focus, if necessary. 18. Position the enclosure lid and close it. If using the 10-24 x 0.75-inch hex head screws, tighten them using a 5-mm Allen wrench (not supplied). If using the optional security kit, insert the three tamper-resistant screws (supplied) and tighten them using the 1/8-inch hollow screwdriver bit (supplied). When tightening either kind of screw, ensure that the gasket is properly seated. 120 VAC MODEL WIRING 24 VAC CAMERA OUTPUT 24 VAC C
Summary of the content on the page No. 11
INSTALLING THE SUN SHROUD The optional sun shroud fits over the top of the EH1512 enclosure. Perform the following steps to install the sun shroud. 1. Position the front of the sun shroud above the front of the enclosure. 2. Press the sun shroud down and against the enclosure until the sun shroud snaps into place. Table A. Allowable Cable Diameter Gland Cable Diameter PG9 0.181-inch to 0.312-inch PG11 0.230-inch to 0.395-inch NOTE: Conduit must be used if the cable diameter is greater than 0.
Summary of the content on the page No. 12
Table C. 24 VAC Wiring Distances Wire Gauge 2 2 2 2 Total VA 20 AWG (0.5 mm ) 18 AWG (1.0 mm ) 16 AWG (1.5 mm ) 14 AWG (2.5 mm ) 10 283 ft (86 m) 451 ft (137 m) 716 ft (218 m) 1142 ft (348 m) 20 141 ft (42 m) 225 ft (68 m) 358 ft (109 m) 571 ft (174 m) 30 94 ft (28 m) 150 ft (45 m) 238 ft (54 m) 380 ft (115 m) 40 70 ft (21 m) 112 ft (34 m) 179 ft (54 m) 285 ft (86 m) 50 56 ft (17 m) 90 ft (27 m) 143 ft (43 m) 228 ft (69 m) Table C describes the recommended maximum distances for 24 VAC applicati
Summary of the content on the page No. 13
Specifications MECHANICAL Camera Mounting Single slot for adjustable camera positioning on snap-in camera sled † Camera and Lens Size Accepts camera and lens combinations (including BNC connector) up to 9.00" L x 2.87" W x 3.00" H (22.86 x 7.28 x 7.62 cm) ® Viewing Window 0.118-inch (3 mm) thick scratch-resistant Lexan Viewing Area 2.81" W x 2.47" H (7.14 x 6.27 cm) Cable Entry 1 x PG9 and 1 x PG11 compression glands on bottom; PG9 0.312-inch (0.8 cm) and PG11 0.395 (1.0 cm) maximum cable diam
Summary of the content on the page No. 14
RECOMMENDED CAMERAS AND LENSES Cameras C10CH-6, C10CH-6X, C10CH-7X, C10DN-6, C10DN-6X, C10DN-7X, CCC1390H-6, CCC1390H-6X, IP3701H-2, IP3701H-2X, IXS0C, IXS0DN, IX10C, IX10DN, IXE20C, IXE20DN, IX30C, IX30DN Lenses 13VD2.8-12, 13VD3-8, 13VD5-40, 13VD5-50, 13VDIR2.8-11, 13VDIR3-8.5, 13VDIR7.5-50 NOTE: These lenses are for use with all cameras except Pelco IP cameras with Sarix™ technology. Refer to the specific camera specification sheet for information on recommended lenses. (Design and product
Summary of the content on the page No. 15
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in Pelco will warrant all replacement parts and repairs for 90 days from the date of material or workmanship for a period of one year after the date of shipment. Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse, Exceptions to this warranty are as n
Summary of the content on the page No. 16