Summary of the content on the page No. 1
Type 508
ISSUE 1
Downloaded from: http://www.guardianalarms.net
Summary of the content on the page No. 2
Introduction Congratulations on choosing a Dennard Series 508 Camera Housing. This operation manual provides information on the mounting variations, and access to the Series 508 Camera Housings. This operation manual will provide all the necessary information to install the Series 508 Camera Housing. Rotate 180° Unpacking Locking nut Fig.1 Locking nut Fig.2 Method The type 508 housing comes packed in the orientation shown in (fig.1) To bring the 508 into operational service follow the followin
Summary of the content on the page No. 3
List of contents Before installation please remove the components from the packaging and check that all items listed below have been supplied. A. 1 x Type 508 housing G. 1 x Insulating Pad B. 1 x Type 508 Handbook H. 1 x Screw Insulator C. 1 x 3mm A/F Allen Key I. 1 x 1/4 UNC x 3/8 Hex Hd. screw D. 1 x 4mm A/F Allen Key J. 1 x M6 Plain Washer E. 1 x 5mm A/F Allen Key K. 1 x M20 Cable Gland F. 1 x Spanner Component Spares Description Ref.No. Quantity Heater - 240V C590 1 Heater - 110V C622 1
Summary of the content on the page No. 4
Circuit Diagram Unit fitted with a 20 x 5mm 1 Amp fuse as standard. It is the customers responsibility to change the fuse to suit their own application. 508 operation manual Sheet. 3 Cover Earth FS1 FTB L PCB1 E N Chassis Earth PTC Spare PLATFORM TB1
Summary of the content on the page No. 5
Operation 1. Body Camera Platform locates in the middle slots only Arrow A Suspension Platform Hook Bracket View on Arrow A 2. 3. Body Hook Platform Body Suspension Hook Platform Bracket To gain access to the 508 housing the following procedure should be fol- lowed. 1. Remove the 6 off M5 x 20 soc. hd. screws from the back plate, using the 4mm A/F long series ball allen key, these screws are held captive for convenience. 2. Slide the body & sunsheild along the camera platform until it becom
Summary of the content on the page No. 6
Mounting Instructions 1.(2 x M6 x40 Soc. Cap hd screws) 180° 4 x M6 x 16 Soc. Hd. Screws Ceiling mounted configuration Arrow A 2 x M6 Grub Screws View on arrow A Housing body & M20 Cable Gland sunsheild Wall mounted configuration 3. Remove 4 x M6 x 16 Soc. Hd. screws from rear bracket and rotate cast base until desired position of M20 cable gland is acheived. Replace M6 screws and tighten firmly. to convert the housing from wall mounted to ceiling mounted orientation. Remove 2 off fixings (
Summary of the content on the page No. 7
WARNING HOT SURFACE AT ALL TIMES Outline Dimensions 508 Housing Outline Hidden Cable Bracket (Ceiling Mounted Orientation) (-90° tilt down) (+/-90° Pan) A Hidden Cable Bracket (Wall Mounted Orientation) 4 off mounting (-90° tilt down) (+/-90° Pan) holes Ø7.5 equi-spaced Fused Mains Terminal Block and 6 way terminal block on a 101.6 Locking Nuts Customer Cable Run Poly- 260 useable internal length carbonate 551 Window 10mm Thick +/-90° Pan 508 Camera Platform Outline One 3 Way Fused T.B. One 6 W
Summary of the content on the page No. 8
Customer Electrical Connections Housing Wiring Layout 6. 7. 9. Arrow B 8. 5. 1. 10. 4. 2. 3. Components 1. Platform 2. Gasket 3. Housing Back 4. Plate 5. 423 Bracket 6. Assembly 7. Cable Run 8. Locking Nut 9. Rubber 10. Diaphragm 508 operation manual Sheet. 7
Summary of the content on the page No. 9
Customer Electrical Connections L E N 1 to 6 View on Rear T.B.s Arrow B Ref. Function Line L Earth E N Neutral Spare 1 2 Spare Spare 3 Spare 4 5 Spare Spare 6 508 operation manual Sheet. 8 From Heater