Metrologic Instruments MS700i user manual

User manual for the device Metrologic Instruments MS700i

Device: Metrologic Instruments MS700i
Category: Scanner
Manufacturer: Metrologic Instruments
Size: 0.47 MB
Added : 12/30/2013
Number of pages: 57
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Metrologic Instruments MS700i. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Metrologic Instruments MS700i.

For your convenience

If looking through the Metrologic Instruments MS700i user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Metrologic Instruments MS700i on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Metrologic Instruments MS700i to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Metrologic Instruments MS700i User manual - Online PDF
Advertisement
« Page 1 of 57 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Metrologic Instruments MS700i but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Metrologic Instruments MS700i. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Code Projection Scanner
Installation and User’s Guide
MLP N 2178
Printed in USA
October 1998

Series Laser Bar i MS700

Summary of the content on the page No. 2

Table of Contents .................................................. ................................................. ................................... ...................... ................................................ ................................... 6 .................................. ............................... ............ .............................. ....................... 9, 10 ........................................... 11 ............................. 12 ..............

Summary of the content on the page No. 3

i ........................ 25 i ........... 26 i i .................. 27 i i . 28, 29 i ............................ 30 i ........... 31, 32 .................................................. 33 ...................................... 33 ...................................... 34, 35 ..................................... 36-41 .................................... 42-46 ............................. 47, 48 ........................................... 49, 50 ..........................................

Summary of the content on the page No. 4

The MS700 i V L D MS700 i i i 1 15") is ideal. ’s depth of field of 178mm - 381mm (7" - window is preferred, the MS720 accommodate applications where scanning items farther away from the scan ’s depth of field of 0.0mm - 178mm (0" - 7") is ideal. To and MS715 codes immediately on the first pass at any roll angle. For close scanning, the poorly printed bar codes and read torn and bent UPC, EAN and JAN bar With a scan speed of 2,000 lines per second, these scanners aggressively scan compatible sof

Summary of the content on the page No. 5

Unpacking List ! ! ! ! MS700 i /MS715 or MS720 i ! ! ! 2 Stand #45483 (optional) Communication Cable (optional) Communication cable with connection for power supply (optional) or Power Supply (optional) Laser Bar Code Projection Scanner i Volume Control Card (MLPN: 2346) ScanSelect™ Scanner Programming Guide (MLPN: 2186) Installation and User’s Guide (MLPN: 2178) The shipping carton should contain the following:

Summary of the content on the page No. 6

Scanner Connections to the Host S E L V 1. 2. 3. 4. 5. Note: 3 time indicating that the laser is on. startup sequence, the green LED will remain on for a specified then the scanner will beep once. After the scanner performs this When the scanner first receives power, the LEDs will flash and Power up the host system. outlet to supply power to the scanner. located on the communication cable. Plug the transformer into the AC Plug the transformer into the side of the female D-type connector equipmen

Summary of the content on the page No. 7

Configuration of the Scanner to the Host System Default Settings ScanSelect Scanner Programming Guide the ScanSet 1. Scanner Connections to the Host 2. 3. 4. Note: 4 the same interface is selected with ScanSet. Programming Guide do not match the default settings loaded when Non-RS-232 interfaces chosen in Section B of the ScanSelect normal operation.) code again. (The new options will be saved and the scanner is ready for Exit program mode by scanning the ENTER/EXIT program mode bar time. With

Summary of the content on the page No. 8

Cloning Feature 1. 2. 3. 4. 5 CLONING that has the settings that need to be transferred to the other scanner. Once each scanner is ready, scan the cloning bar code with the scanner Turn both scanners on by plugging in the transformers. Connect the cloning cable between the two scanners. Turn off both scanners. scanners. This is done by connecting the cloning cable (MLPN: #51544) between two To program several scanners with the same settings, use the Cloning feature.

Summary of the content on the page No. 9

Warning : Note: 6 this time for IBM 4693 terminals. connecting to an IBM 4694. Metrologic has no recommendations at recommends using an external power supply for the scanner when certain scanner models. Specifically, Metrologic currently and IBM 4694 terminals may be restricted from supplying power to record of supplying power to Metrologic scanners. The IBM 4693 The IBM 4683 and IBM 4684 terminals have a good proven track use at the site. which operating system (4680.OS, 4690.OS, POS/DOS or DOS

Summary of the content on the page No. 10

ON ON ON ON 7 Should be OFF (Reserved) Switch 8 Must be ON Switches 4, 5, 6, and 7 Reserved (Should be OFF) Switch 3 Reserved Port 17, IBM 4014 Adaptor for 3687-2 to 468X OFF Port 9B, CCD (IBM 4500/Opticon) OFF (default setting) Port 5B, IBM 1520 Model 2 Laser Scanner OFF OFF Emulation Mode Switch 2 Switch 1 switches. There are eight DIP switches on the board that are both software and hardware 46XX SIOC communications. is a list of switch settings for the internal interface board that handles t

Summary of the content on the page No. 11

8 scanner has been selected. selected. Initialize the RIPPS drivers for a "POS scanner" if the 3687-2 Initialize the RIPPS drivers for a hand scanner if hand scanner emulation was IBM 4684 and 4694 Systems configuration to the terminal(s) per standard procedures. Save the configuration and activate it for the desired terminals. Download the base of users. configuration and device driver support would be provided for the installed While IBM has withdrawn this product, it was not clear how termina

Summary of the content on the page No. 12

Scanner Installation to a PC Keyboard Port The MS700 i /MS715 i /MS720 PC Type ® ! ! XT ! Keyboard Country Type ! USA ! ! ! ! ! ! ! ® 9 Guide or ScanSet™ Scanner Configuration Guide. delay. For further information, refer to the ScanSelect™ Scanner Programming recall defaults, select the PC type, keyboard country type and intercharacter interface. For instance, to configure the scanner for keyboard wedge emulation, interface versus another, change all necessary parameters for that particular 232

Summary of the content on the page No. 13

S E L V 1. (#51573) the 5M 6F 2. 3. 4. 5. 6. 7. 8. 10 Turn the PC on. outlet to supply power to the scanner. located on the communication cable. Plug the transformer into the AC Plug the transformer into the side of the female D-type connector easily accessible.) (A socket-outlet shall be installed near the equipment and shall be voltage matches the AC outlet. Check the AC input requirements of the transformer to make sure the communication cable. Connect the 25-pin D-type connector on the scan

Summary of the content on the page No. 14

Note: 11 green LED will remain on for a specified time indicating the laser is on. will beep once. After the scanner performs this startup sequence, the the scanner first receives power, the LEDs will flash and then the scanner ever, bar codes will not be read until the scanner receives power. When normally even if the scanner's transformer plug is not in. How- Once the scanner connects to the PC, the PC can be turned on and will operate inter scan code options. Network system installatio

Summary of the content on the page No. 15

Installation of the MS700 Series Stand 1 4 2 5 3 6 7 1. 2. 3. 4. 5. 12 screw the shoe to the shaft with the machine screw. Place the internal lock washer on top of the flexible shaft and then Screw the flexible shaft to the stand base. Position the stand cover on top of the stand base. Use the four wood screws to secure the base to the work surface. holes. Use the 2½ inch x 2½ inch stand base to mark the position for pilot Flexible Shaft Internal Lock Washer Stand Base One Machine (¼-20) Screw S

Summary of the content on the page No. 16

1. 2. 3. Note : 13 Figure 3 push the shaft to a north, south, east, or west direction. the flexible shaft. To adjust the angle, firmly hold the shaft and Fasten the stand to the work surface before adjusting the angle of shoe. This screw holds the scanner in place. Tighten the small screw (A) located at the center of the long part of the scanner into position. Align the foot of the scanner with the shoe of the stand and slide the 3/32" hex key wrench. (Refer to Figure 3) small screw (A) located

Summary of the content on the page No. 17

i and i Features 1 Speaker 2 3 InfraRed Object 4 Head Cable 5 14 This aperture emits laser light. Output Window device or to a communication cable. This cable can connect directly to the host hand is passed in front of the IR sensor. to scanning until an object or a wave your “standby” mode. The scanner will not return without any scanning, the unit will enter a Sensor When a specified time has elapsed complete. light turns off, communication to the host is read a bar code successfully. When th

Summary of the content on the page No. 18

Steady Red and Green Alternating Red and Green Steady Red Flashing Red 15 repair at an authorized service center. This indicates the scanner has experienced a laser subsystem failure. Return the unit for This indicates the scanner is in ScanSet mode. This indicates the scanner is in program mode. data can be transmitted. is not ready to accept the information, the scanner’s red LED will remain on until the After a successful scan, the scanner transmits the data to the host device. When the host

Summary of the content on the page No. 19

Signaux optiques 16 concessionnaire pour réparation. Indique une panne de laser pendant la lecture. Veuillez envoyer votre appareil chez un Diode rouge clignotante Indique que le scanner se trouve en mode ScanSet. La diode rouge reste allumée Indique que le scanner se trouve en mode de programmation. Les diodes rouges et vertes clignotent en alternance reste allumée jusqu'à ce que les données puissent être transmises. central. Si ce dernier n'est pas prêt à recevoir les données, la diode rouge d

Summary of the content on the page No. 20

17 Vertragsservicecenter. Bringen Sie das Gerät zur Reparatur in ein Zeigt an, daß beim Scanner ein Laserausfall vorliegt. Aufblinkende rote Leuchtanzeige Zeigt an, daß sich der Scanner im ScanSet-Modus befindet. Feststehende rote Leuchtanzeige Zeigt an, daß sich der Scanner im Programmiermodus befindet. Alternierende rote und grüne Leuchtanzeige können. werden Daten übertragen bis die des Scanners solange auf, das Hostgerät zur Datenannahme nicht bereit ist, leuchtet die rote Leuchtdiodenanze


Alternative user manuals
# User manual Category Download
1 Metrologic Instruments 160 User manual Scanner 5
2 Metrologic Instruments FocusBT MS1633 User manual Scanner 15
3 Metrologic Instruments Cubit MS6520 Series User manual Scanner 66
4 Metrologic Instruments Cubit IS6520 Series User manual Scanner 83
5 Metrologic Instruments Genesis MS7580 User manual Scanner 44
6 Metrologic Instruments 185 User manual Scanner 0
7 Metrologic Instruments FOCUSE IS1650 User manual Scanner 3
8 Metrologic Instruments iQ160 User manual Scanner 0
9 Metrologic Instruments Hand-Held User manual Scanner 1
10 Metrologic Instruments FocusBT MS9535 User manual Scanner 387
11 Metrologic Instruments ARGUSSCANTM MS7220 User manual Scanner 4
12 Metrologic Instruments IS4813 User manual Scanner 2
13 Metrologic Instruments IS4823 User manual Scanner 0
14 Metrologic Instruments IS4910 Series User manual Scanner 0
15 Metrologic Instruments IS4825 User manual Scanner 2
16 Sony ICF-SC1 User manual Scanner 11
17 Sony SFM1 User manual Scanner 1
18 Sony ICF-SC1PC User manual Scanner 9
19 3M G4000 User manual Scanner 3
20 3M G4000 User manual Scanner 1