Honeywell STR12D user manual

User manual for the device Honeywell STR12D

Device: Honeywell STR12D
Category: Satellite Radio
Manufacturer: Honeywell
Size: 1.61 MB
Added : 7/16/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell STR12D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell STR12D.

For your convenience

If looking through the Honeywell STR12D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell STR12D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell STR12D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell STR12D User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell STR12D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell STR12D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


34-ST-03-64
ST 3000 Smart Transmitter
2/08
Series 100 Remote Diaphragm Seals Models
Specification and
STR12D 0-10 to 0-400 inH O 0-25 to 0-1000 mbar
2
STR13D 0-5 to 0-100 psid 0-0.35 to 0-7 bar
Model Selection
STR14G 0-5 to 0-500 psig 0-0.35 to 0-35 bar
STR17G 0-100 to 0-3000 psig 0-7 to 0-210 bar
Guide
STR14A 0-5 to 0-500 psia 0-0.35 to 0-35 bar


Introduction


In 1983, Honeywell introduced the first
Smart Pressure Transmitter

Summary of the content on the page No. 2

34-ST-03-64 Page 2 Description of Diaphragm Seals Diaphragm seals are traditionally used when a standard pressure transmitter should not be exposed to the process pressure directly. Diaphragm seals typically protect the pressure transmitter from one or more damaging aspects of the process media. Consideration for using a diaphragm seal should be made in the following circumstances. • High Process Temperature • Process Media is Viscous or Contains Suspended Solids • Process Media

Summary of the content on the page No. 3

34-ST-03-64 Page 3 Description of Diaphragm Seals Figure 6 - Seals with Threaded Process Connections can be used with differential, gauge and absolute pressure transmitters and are available with ½”, ¾” and 1” NPT Female process connections. Figure 6 Figure 7 - Sanitary Seals can be used with differential, gauge and absolute pressure transmitters and are available with 3” and 4” Tri-Clover-Tri-Clamp process connections. Figure 7 Figure 8 - Saddle Seals can be

Summary of the content on the page No. 4

34-ST-03-64 Page 4 Figure 12 - Welded Meter Body for All-Welded Remote Seal Solution. The welded ST 3000 meter body is an important part of an All-Welded Remote Seal Solution, which is commonly used in Vacuum applications. Figure 12 Description Features • Choice of linear or square root The ST 3000 transmitter can replace any 4 to 20 mA output output conformity is a simple transmitter in use today and operates over a standard two-wire configuration selection.

Summary of the content on the page No. 5

34-ST-03-64 Page 5 Specifications Operating Conditions – All Models Parameter Reference Condition Rated Condition Operative Limits Transportation and Storage °C °F °C °F °C °F °C °F Ambient Temperature * 25 ±1 77 ±2 — — — — –55 to 90 –67 to 194 Humidity % RH 10 to 55 0 to 100 0 to 100 0 to 100 Maximum Allowable MAWP is minimum of Body Rating or Seal Rating (See Model Selection Guide for Seal Working Pressure (MAWP) MAWP) Body MAWP STR12D 2500 psig (17

Summary of the content on the page No. 6

34-ST-03-64 Page 6 Performance Under Rated Conditions * - Model STR12D (0-10 to 0-400 inH O) 2 Parameter Description Upper Range Limit ** inH2O 400 (39.2°F/4°C is standard reference temperature for inH O range.) 2 mbar 1000 Minimum Span inH2O 10 Note: Recommended minimum span in square root mode is 20 inH O (50 mbar). 2 mbar 25 Turndown Ratio 40 to 1 Zero Elevation and Suppression No limit except minimum span within ±100% URL. Accuracy (Reference – Includes In Analog Mode: ±0.2

Summary of the content on the page No. 7

34-ST-03-64 Page 7 Performance Under Rated Conditions * - Model STR13D (0-5 to 0-100 psid) Parameter Description Upper Range Limit ** psid 100 bar 7 Minimum Span psid 5 bar 0.35 Turndown Ratio 20 to 1 Zero Elevation and Suppression No limit except minimum span within –18% and +100% of URL. Specifications valid from –5% to 100% of URL. Accuracy (Reference – Includes In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is combined effects of linearit

Summary of the content on the page No. 8

34-ST-03-64 Page 8 Performance Under Rated Conditions * - Model STR14G (0-5 to 0-500 psig) Parameter Description Upper Range Limit ** psig 500 bar 35 Minimum Span psig 5 bar 0.35 Turndown Ratio 100 to 1 Zero Elevation and Suppression No limit except minimum span from absolute zero to 100% of URL. Specifications valid over this range. Accuracy (Reference – Includes In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is combined effects of linearity, g

Summary of the content on the page No. 9

34-ST-03-64 Page 9 Performance Under Rated Conditions * - Model STR17G (0-100 to 0-3000 psig) Parameter Description Upper Range Limit ** psig 3000 bar 210 Minimum Span psig 100 bar 7 Turndown Ratio 30 to 1 Zero Elevation and Suppression No limit except minimum span from absolute zero to 100% of URL. Specifications valid over this range. Accuracy (Reference – Includes In Analog Mode: ±0.15% of calibrated span or upper range value (URV), whichever is combined effects of line

Summary of the content on the page No. 10

34-ST-03-64 Page 10 Performance Under Rated Conditions * - Model STR14A (0-5 to 0-500 psia) Parameter Description Upper Range Limit ** psia 500 bar absolute 35 Minimum Span psia 5 bar absolute 0.35 Turndown Ratio 100 to 1 Zero Elevation and Suppression No limit except minimum span from 0 to 100% URL. Accuracy (Reference – Includes In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is combined effects of linearity, greater. hysteresis, and repeata

Summary of the content on the page No. 11

34-ST-03-64 Page 11 Physical and Approval Bodies Parameter Description Process Interface See Model Selection Guide for Material Options for desired seal type. Seal Barrier Diaphragm 316L Stainless Steel, Monel, Hastelloy C, Tantalum Seal Gasket Materials Klinger C-4401 (non-asbestos) Grafoil Teflon Gylon 3510 Mounting Bracket Carbon Steel (Zinc-Chromate plated) or Stainless Steel. Fill Fluid (Meter Body) Silicone (DC 200) S.G. @ 25°C = 0.94 CTFE (Chlorotrifluoroethylene) S.G. @ 2

Summary of the content on the page No. 12

34-ST-03-64 Page 12 Parameter Description Pressure Equipment Directive The ST 3000 pressure transmitters listed in this Specification have no pressurized (97/23/EC) internal volume or have a pressurized internal volume rated less than 1,000 bar (14,500 psig) and/or have a maximum volume of less than 0.1 liter. Therefore, these transmitters are either; not subject to the essential requirements of the directive 97/23/EC (PED, Annex 1) and shall not have the CE mark, or the manufacturer

Summary of the content on the page No. 13

34-ST-03-64 Page 13 Figure 15—ST 3000 Remote Seals operable limits for pressure vs. temperature.

Summary of the content on the page No. 14

34-ST-03-64 Page 14 1440 1440 1200 1200 Not Note e: A : A minimu minimum m of of 2 25 50 o 0 oh hms ms Loop Loop 800 800 of of loop r loop re esist sistan ance is n ce is ne ece cessa ssary ry Re Resi sistan stanc ce e to to suppo suppor rtt co com mm mun uniicat catiion ons. s. (ohm (ohms) s) 650 650 Loop r Loop re esist sistan ance ce equa equals ba ls bar rr riie er r r re esistance plus w sistance plus wiir re e resistanc resistance e plus rec plus rece eiver resista iver re

Summary of the content on the page No. 15

34-ST-03-64 Page 15 Application Data* Max Level LP Liquid Level: Closed Tank Determine the minimum and maximum pressure differentials to be measured (Figure 18). b P = (SG x a) – (SG x d) Min p f Min = LRV when HP at bottom HP Level of tank a = –URV when LP at bottom of tank Transmitter above datum P = (SG x b) – (SG x d) Max p f = URV when HP at bottom of tank Max LP = –LRV when LP at bottom Level of tank Where: b Minimum level at 4 mA Maximum leve

Summary of the content on the page No. 16

34-ST-03-64 Page 16 Density or Interface* Calculate the minimum and maximum pressure differentials to be measured. P = (SG - SG ) x (d); min min f LP minimum density, 4mA output P = (SG - SG ) x (d); max max f maximum density, 20mA output Where: HP d = distance between the taps 24257 SG = maximum Specific max Gravity SG = minimum Specific min Gravity SGf = Specific Gravity of capillary fill fluid (see page 11 for values) Figure 19—Dens

Summary of the content on the page No. 17

34-ST-03-64 Page 17 82.9 94.9 With Smart meter With Analog 3.26 3.74 meter 53.1 65.1 3.6 135 Reference Removal 45.7 2.09 2.56 5.32 0.14 Without Without Clearance 1.8 Dimensions: meter meter Plug for All Caps millimeters 55.3 inches 2.18 Optional meters 23.5 .925 Rotational Optional external STR12D, STR13D lock ground DP/I Remote Seal LP seal with Horizontal omitted for Pipe Mount clarity 85 3.35 42.5 50 1.97 1.67 82.9 94.9 With Smart meter With Analog meter 3.26 3.74 53

Summary of the content on the page No. 18

34-ST-03-64 Page 18 82.9 94.9 With Smart meter With Analog 3.26 3.74 meter 53.1 65.1 Reference 3.6 135 Removal 45.7 2.09 2.56 Dimensions: 5.32 0.14 Without Without 1.8 Clearance meter meter Plug millimeters for All Caps inches 55.3 2.18 Optional meters 23.5 .925 LP seal Rotational omitted Optional external lock for clarity ground STR12D, STR13D 85 DP/I Remote Seal 3.35 with Vertical SQ Pipe Mount 50 42.5 1.97 1.67 82.9 94.9 With Smart meter With Analog 3.26 3.74 meter

Summary of the content on the page No. 19

34-ST-03-64 Page 19 Options Ordering Information Mounting Bracket NAMUR NE43 Compliance Contact your nearest Honeywell sales The angle mounting bracket is (Option NE) office, or available in either zinc-plated This option provides software the carbon steel or stainless steel and meets the NAMUR NE43 In the U.S.: is suitable for horizontal or vertical requirements for failsafe software. Honeywell mounting on a two inch (50 Transmitter failure information is Industrial

Summary of the content on the page No. 20

34-ST-03-64 Page 20 Model Selection Guide (34-ST-16-32) Model Selection Guide 34-ST-16-32 Issue 39 Instructions ● Select the desired Key Number. The arrow to the right marks the selection available. ● Make one selection from each Table I and II using the column below the proper arrow. ● Select as many Table III options as desired (if no options or approvals are desired, specify 9X). ● A ( ●) denotes unrestricted availability. A letter denotes restricted availability.


Alternative user manuals
# User manual Category Download
1 Honeywell ADEMCO 5817 User manual Satellite Radio 13
2 Honeywell ST 3000 User manual Satellite Radio 3
3 Honeywell ST 3000 SMART TRANSMITTER STR93D User manual Satellite Radio 83
4 Honeywell ST 3000 User manual Satellite Radio 521
5 Honeywell SMV 3000 User manual Satellite Radio 27
6 Honeywell ST 3000 SMART TRANSMITTER STR94G User manual Satellite Radio 9
7 Sony DRN-XM01HK2 User manual Satellite Radio 1
8 Sony 3-873-945-12 (1) User manual Satellite Radio 0
9 Sony SA-VE812ED User manual Satellite Radio 1
10 Sony DRN-XM01R2 User manual Satellite Radio 0
11 Sony AIR-SA17TI User manual Satellite Radio 6
12 Sony SAT-HD100 User manual Satellite Radio 2
13 Sony 346 User manual Satellite Radio 0
14 Sony E672 User manual Satellite Radio 0
15 Sony User manual Satellite Radio 0