Magnetek 188-10130 user manual

User manual for the device Magnetek 188-10130

Device: Magnetek 188-10130
Category: Remote Starter
Manufacturer: Magnetek
Size: 1.12 MB
Added : 1/25/2014
Number of pages: 67
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Magnetek 188-10130. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Magnetek 188-10130.

For your convenience

If looking through the Magnetek 188-10130 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Magnetek 188-10130 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Magnetek 188-10130 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Magnetek 188-10130 User manual - Online PDF
Advertisement
« Page 1 of 67 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Magnetek 188-10130 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Magnetek 188-10130. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

RVS-DX Digital Soft Starter
Instruction Manual
Power Control Systems
April 1, 2004
Part Number: 188-10130
© Copyright 2004 Magnetek

Summary of the content on the page No. 2

Contents: Disclaimer of Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii-iii Chapter1: Introduction Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Starter Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Chapter 2: Installation Physical Installat

Summary of the content on the page No. 3

Chapter 7: Start-Up Procedure Start-Up Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 Start-Up Procedure with Pump Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5 Chapter 8: Troubleshooting Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Appendix A: Technical Data/Specifications T

Summary of the content on the page No. 4

©2004 MAGNETEK All rights reserved. This notice applies to all copyrighted materials included with this product, including, but not limited to, this manual and software embodied within the product. This manual is intended for the sole use of the persons to whom it was provided, and any unauthorized distribution of the manual or dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by any means whatsoever without the expressed written permissio

Summary of the content on the page No. 5

Disclaimer of Warranty Magnetek, hereafter referred to as Company, assumes no responsibility for improper programming of a soft starter by untrained personnel. A soft starter should only be programmed by a trained technician who has read and understands the contents of this manual. Improper programming of a soft starter can lead to unexpected, undesirable, or unsafe operation or performance. This may result in damage to equipment or personal injury. Company shall not be liable for economic

Summary of the content on the page No. 6

ATTENTION 1. This product was designed for compliance with IEC 947-4-2 for class A equipment. 2. RVS-DX are listed under UL508C. RVS-DX, Digital Soft Starter Instruction Manual—4/01/04 iii

Summary of the content on the page No. 7

chapter 1 Introduction

Summary of the content on the page No. 8

This page intentionally left blank.

Summary of the content on the page No. 9

Overview The RVS-DX is a digital electronic soft starter, incorporating six SCR’s to start a three phase squirrel cage induction motor by supplying a slowly increasing voltage, providing soft start and smooth stepless acceleration, while drawing the minimum current necessary to start the motor. The RVS-DX is equipped with internal bypass relays initiated by its microprocessor control (on units 31-310 amps). Using the soft stop, the RVS-DX slowly reduces the motor voltage, thus softly stoppin

Summary of the content on the page No. 10

Model Number Max. FLA Frame Size 230/460 Volts* 575 Volt 8 RVS-DX-8-D RVS-DX-8-E 17 RVS-DX-17-D RVS-DX-17-E A1 31 RVS-DX-31-D RVS-DX-31-E 44 RVS-DX-44-D RVS-DX-44-E 58 RVS-DX-58-D RVS-DX-58-E A2 72 RVS-DX-72-D RVS-DX-72-E 85 RVS-DX-85-D RVS-DX-85-E A3 105 RVS-DX-105-D RVS-DX-105-E 145 RVS-DX-145-D RVS-DX-145-E A4 170 RVS-DX-170-D RVS-DX-170-E 210 RVS-DX-210-D RVS-DX-210-E A5 310 RVS-DX-310-D RVS-DX-310-E 390 tbd RVS-DX-390-D RVS-DX-390-E *Dual rated soft starters come pre-set for 460 volts. To s

Summary of the content on the page No. 11

chapter 2 Installation

Summary of the content on the page No. 12

This page intentionally left blank.

Summary of the content on the page No. 13

Physical Installation Location of the RVS-DX is important to achieve proper performance and normal operating life. The unit should be installed in an area where it will be protected from: • Direct sunlight, rain or moisture • Corrosive gases or liquids • Vibration, airborne dust or metallic particles When preparing to mount the RVS-DX, lift it by its base, never by the front cover. For effective cooling as well as proper maintenance, the RVS-DX must be installed on a flat, non-flammable verti

Summary of the content on the page No. 14

Built in Bypass After Acceleration The bypass after acceleration allows the RVS-DX to control the motor during starting and stopping for smooth, step-less acceleration and deceleration. However, once up to full voltage the RVS-DX is bypassed to reduce the watt loss. The RVS-DX incorporates internal bypass relays allowing current flow through the SCR’s only during the soft start process. At the end of the soft start, the built-in relays bypass the SCR’s and carry current to the motor. Upon st

Summary of the content on the page No. 15

chapter 3 RVS-DX Terminals and Wiring

Summary of the content on the page No. 16

This page intentionally left blank.

Summary of the content on the page No. 17

Control Terminals Terminal Function Description A1 Control Supply 120V control power must be connected at terminals A1 & A2. (Note 1) A2 Input from a N.O. maintained contact. Connect terminals A2 & B1 to start, and B1 Start/Stop open to stop. Input from a N.O. maintained contact. Connect terminals A2 & C1 to operate C1 Aux. Input the function. (Note 2) Auxiliary Output 13 Contact N.O. output contact can be set to Immediate or End of Acceleration. (Note 3). 14 (Note 3) 23 Fault Contact N.O.

Summary of the content on the page No. 18

Typical Wiring Diagram RVS-DX, Digital Soft Starter Instruction Manual—04/01/04 3-4

Summary of the content on the page No. 19

Operating “Inside the Delta” Using the RVS-DX soft starter “inside the delta” reduces the required soft starter rating by 1.73 ( √3) factor. For example, for a 150 amp, 460 volt motor, the RVS-DX-170-D is selected to operate in standard “line” mode. However, for “inside the delta” mode (150 amp ÷1.73=87 amps), the RVS- DX-105-D can be selected, thereby, reducing cost and physical space in the application. The following programming parameters are disabled, once the ‘inside the delta’ is selecte

Summary of the content on the page No. 20

Typical Wiring for Inside the Delta Operation: RVS-DX, Digital Soft Starter Instruction Manual—04/01/04 3-6


Alternative user manuals
# User manual Category Download
1 Edelbrock 1797 User manual Remote Starter 0
2 Sony XR-C5300RX User manual Remote Starter 25
3 Sony RM-V12 User manual Remote Starter 124
4 Altech Auto Security 5BCR10P User manual Remote Starter 43
5 APC REMOTE POWER-OFF DEVICE AP9830 User manual Remote Starter 8
6 AstroStart 2205A User manual Remote Starter 16
7 AstroStart 2504A User manual Remote Starter 1
8 AstroStart 4204 User manual Remote Starter 1
9 AstroStart 502 User manual Remote Starter 0
10 AstroStart 3106U User manual Remote Starter 3
11 AstroStart 2106U User manual Remote Starter 4
12 AstroStart 2305A User manual Remote Starter 0
13 AstroStart 5204U User manual Remote Starter 0
14 AstroStart 4204U User manual Remote Starter 0
15 AstroStart 803U User manual Remote Starter 5