Summary of the content on the page No. 1
INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING GAS RANGE
with standard clean oven
Table of Contents..................................................2
IMPORTANT: Save for local electrical inspector’s use.
W10032070
Summary of the content on the page No. 2
TABLE OF CONTENTS RANGE SAFETY .......................................................................... 2 INSTALLATION REQUIREMENTS .............................................. 4 Tools and Parts .......................................................................... 4 Location Requirements.............................................................. 4 Electrical Requirements ............................................................ 6 Gas Supply Requirements ...........................
Summary of the content on the page No. 3
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
Summary of the content on the page No. 4
INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Do Read and follow the instructions provided with any tools listed not obstruct flow of combustion and ventilation air. here. ■ It is the installer’s responsibility to comply with installation Tools needed clearances specified on the model/serial rating plate. The model/serial rating plate is located on the oven f
Summary of the content on the page No. 5
Product Dimensions Installation Clearances Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height. If the cabinet depth is greater than 24" (61 cm), the oven frame must extend beyond cabinet fronts by ¹⁄₂" (13 mm) minimum. 13" (33.0 cm) max. upper cabinet depth 26-3/4" (67.9 cm) 30" (76.2 cm) min. For minimum depth with cabinet opening width clearance to 36" handle top of cooktop, (91.4 cm) 30-1/8" (76.5 cm) see
Summary of the content on the page No. 6
Electrical Requirements Gas Supply Requirements WARNING WARNING Electrical Shock Hazard Explosion Hazard Plug into a grounded 3 prong outlet. Use a new CSA International approved gas supply line. Do not remove ground prong. Install a shut-off valve. Do not use an adapter. Securely tighten all gas connections. Do not use an extension cord. If connected to LP, have a qualified person make sure Failure to follow these instructions can result in death, gas pressure does not exceed 14" (36 cm) water
Summary of the content on the page No. 7
Flexible metal appliance connector: Burner Input Requirements ■ If local codes permit, a new CSA design-certified, 4-5 ft (122-152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible Input ratings shown on the model/serial rating plate are for metal appliance connector may be used for connecting range elevations up to 2,000 ft (609.6 m). to the gas supply line. For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level. Gas Sup
Summary of the content on the page No. 8
INSTALLATION INSTRUCTIONS Contact a qualified floor covering installer for the best procedure Unpack Range for drilling mounting holes through your type floor covering. Before moving range, slide range onto shipping base, cardboard WARNING or hardboard. Excessive Weight Hazard 1. Remove template from the anti-tip bracket kit (found inside the oven cavity). Use two or more people to move and install range. 2. Place template on the floor in the cabinet opening so that the Failure to do so can resu
Summary of the content on the page No. 9
3. If range is not level, pull range forward until rear leveling leg is 8. Move the range close to the opening. Remove the shipping removed from the anti-tip bracket. Use ³⁄₈" drive ratchet and base, cardboard or hardboard from under the range. slip-joint pliers to adjust leveling legs up or down until range is 9. Open the broiler door. Use a 3/8" drive ratchet to lower the level. rear leveling legs one-half turn. Use flip-joint pliers to lower 4. Push range back into position. the front l
Summary of the content on the page No. 10
Complete Connection Check Operation 1. Locate gas pressure regulator in the broiler. Electronic Ignition System A Cooktop and oven burners use electronic ignitors in place of standing pilots. When a cooktop control knob is turned to the “LITE” position, the system creates a spark to light the burner. This sparking continues until the control knob is turned to the desired setting. A. Gas pressure regulator When the oven control is turned to the desired setting, a hot surface ignitor heats to a br
Summary of the content on the page No. 11
6. When the flame has been properly adjusted, turn the oven off, Check Operation of Oven/Broil Burner wait for the burner to cool down. 1. Open broiler door. A 2. Push in and turn the oven control knob to “350˚F.” The oven pilot should now be larger with the flame burning against a B small metal bulb. The oven burner should light in 20–40 seconds; this delay is normal. The oven valve requires a A. Shutter screw certain time before it will open and allow gas to flow. B. Air shutter To avoid dama
Summary of the content on the page No. 12
GAS CONVERSIONS 2. Unplug or disconnect power. WARNING 3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment. A Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. A. Gas pressure regulator If connected to LP, have a qualified person make sure IMPORTANT: Do not remove the gas pressure regulator. gas pressure does not exceed 14"
Summary of the content on the page No. 13
2. Locate LP gas orifice spuds for top burners in the bag To Convert Oven Burner containing literature included with the range. Three LP gas spuds are stamped “88” and one “96.” 1. Open oven door and remove oven racks, oven tray, flame 3. Remove natural gas orifice spuds using a 7mm combination spreader and set aside. wrench. 2. Lift oven burner. The orifice spud is behind the oven burner air 4. Install LP gas orifice spuds. shutter. NOTE: Depending on model, the range cooktop may be 3. Locate
Summary of the content on the page No. 14
5. Turn the cap over so that N or NAT is visible. Natural Gas Conversion A WARNING A. Cap 6. Reinstall the cap. Tip Over Hazard A child or adult can tip the range and be killed. To Convert Surface Burners Connect anti-tip bracket to rear range foot. 1. Remove burner grates, burner caps, and burners. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. A To Convert Gas Pressure Regulator 1. Ensure
Summary of the content on the page No. 15
4. Install natural gas orifice spuds. 5. Install the number “47” natural gas spud. NOTE: Depending on model, the range cooktop may be IMPORTANT: Do not over tighten. equipped with 4 standard burners or 3 standard burners and 6. Place LP gas oven burner spud in plastic parts bag along 1 power burner. Spud size/location remain the same. with LP gas cooktop burner spuds for future use and keep with bag containing literature. 7. Reinstall oven burner. 8. Reinstall oven racks, oven tray and flame spr
Summary of the content on the page No. 16
W10032070 Printed in Mexico ©2006 Whirlpool Corporation 07/2006 All rights reserved.