Summary of the content on the page No. 1
Installation Instructions
® ™
Preference and Millennia Ranges
For use with models: MRES30, RSD30, RSE30
SAVE ANd REAd ThESE INSTRUCTIONS
TESTEd IN ACCORdANCE wITh ThE LATEST EdITION OF ANSI Z21.1 STANdARd FOR hOUSEhOLd GAS
COOkING APPLIANCES.
CONVENTIONS USEd IN ThESE INSTRUCTIONS
wARNINGS:
Must be followed carefully to avoid personal injury or damage.
NOTES:
Contain helpful hints and tips to facilitate the installation.
IMPORTANT
1. Before beginning installation, pleas
Summary of the content on the page No. 2
IMPORTANT SAFETY INSTRUCTIONS wARNINGS: 7. This appliance must not NOTE: be used in combination 1. Read all instructions before 1. Some products, such as whole with surface (countertop) using the appliance. eggs, and sealed containers, ventilation systems. The use such as closed glass jars, may of an overhead hood, or dacor 2. If the information in this explode and should not be Raised Vent is recommended manual is not followed exactly, heated on this cooktop. for ventilation. a fir
Summary of the content on the page No. 3
Verifying the Package Contents If any item is missing or damaged, please dacor dedicated Total Min. gas contact your dealer immediately. Do not install a Model electrical connected Manifold supply damaged or incomplete appliance. Number circuit required load Gas type pressure pressure All Ranges • Use & Care Manual RSD30 4” water 5” water Natural • Anti-tip Bracket column column 120/240VAC, 5.4kW (23.3A) • Broiler Grill and Pan 60Hz, 30A RSD30LP 10” water 11” water • Oven Racks Liquid Prop
Summary of the content on the page No. 4
Utilities may be located: Contact your local building department to verify Overall dimensions 1. In the lower left corner of the adjacent right compliance with local code interpretation. cabinet. (Recommended) 2. Alternate location, in the lower right corner behind the range. (Note: Some building departments do not permit concealing gas valves behind appliances.) 36" (914mm) Recommended 30" (762mm) Min. Hood 13" (330mm) Max. 25" (635mm) RSd30 Overall dimensions (dual Fuel) Vertical Top of
Summary of the content on the page No. 5
30" Removing the Oven door 4. do not install a fuse in the (762mm) neutral or ground circuit. A wARNINGS: fuse in the neutral or ground circuit may result in an 1. do not attempt to disengage 23 1/2" electrical shock hazard. Range Top the hinge catches with the (597mm) 5. do not ground the appliance door removed from the oven. 26 9/16" to a gas supply pipe or hot The hinge springs could Rear of Control (675mm) water pipe. Panel/Oven Door release causing personal 6. A grounded cold w
Summary of the content on the page No. 6
4. Connect the red appliance wire to the red wARNING: 5. The maximum gas supply (L2) power supply wire in the junction box. pressure to the appliance gas **do not connect the green 5. Connect the green appliance wire to a pressure regulator must never grounded supply wire in the junction box or appliance wire to the neutral exceed 1/2 pound per square to a grounded cold water pipe. (white) supply wire unless local 6. If connecting to a grounded cold water inch (3.5kPa). building code
Summary of the content on the page No. 7
NOTE: Verify Proper Operation for Electric Ranges (RSE and MRES) Prior to operating the cooktop or For RSE range top, rotate one surface element oven sections of the range, please knob at a time, counterclockwise, to the “HI” read the accompanying Use and position. Within 5 seconds, the element should be fully energized and glowing red. Verify that Care Manual carefully. Important the residual heat indicator light comes on in safety, service and warranty conjunction with the proper el
Summary of the content on the page No. 8
The information and images in this book are the copyright property of distinctive Appliances Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of distinctive Appliances Inc. Web Site: www.Dacor.com Corporate Phone: (800) 793-0093 Copyright © 2006 dacor, all rights reserved.