GE AE0CD20DM user manual

User manual for the device GE AE0CD20DM

Device: GE AE0CD20DM
Category: Air Conditioner
Manufacturer: GE
Size: 6.38 MB
Added : 5/20/2014
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE AE0CD20DM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE AE0CD20DM.

For your convenience

If looking through the GE AE0CD20DM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE AE0CD20DM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE AE0CD20DM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE AE0CD20DM User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE AE0CD20DM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE AE0CD20DM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Safety Instructions . . . . . . . . . . . . 2
Owner’s Manual and
Installation Instructions
Operating Instructions
Cool Only Models
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Care and Cleaning . . . . . . . . . . . . . . .6, 7 AE1CD10AM / AE0CD10AM
Remote Control Features . . . . . . . . 4, 5
AE1CD14DM / AE0CD14DM
AE1CD20DM / AE0CD20DM
Installation Instructions
Air Purging and Leakage Test . . . . . 15
Heat/Cool Models
Before You Begin . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 2

IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS  Use this equipment only for its intended  All electrical work must be completed by a purpose as described in this Owner’s qualified electrician and completed to local Manual. and national building codes and regulations.  This system must be properly installed  Any servic

Summary of the content on the page No. 3

Operating Installation Safety Instructions Troubleshooting Tips Consumer Support Instructions Instructions Operating the air conditioner. GEAppliances.com General Procedure NOTE: For best results, point the remote control Press the FAN pad to set the desired fan speed 4 at the indoor unit. (AUTO/Low/Medium/High). Make sure power is connected and press the Press the TEMP +/– pads to set the desired 1 5 ON/OFF pad to start the system. temperature. Press the MODE pad to select the desired NOTE: For

Summary of the content on the page No. 4

About the remote control. The remote control transmits the signals to the system. Features and appearance may vary. AUTO—In this mode, the unit automatically controls the room temperature within the range of 77ºF and 68ºF. The fan will run continuously while the unit is in AUTO mode. Fan setting Operation When the room temperature exceeds 77ºF, the Mode unit will go into COOL Mode. When the room temperature drops to 73ºF, the fan will Sleep on Temperature continue to run but COOL Mode will turn

Summary of the content on the page No. 5

Operating Installation Safety Instructions Troubleshooting Tips Consumer Support Instructions Instructions About the remote control. (cont.) GEAppliances.com The remote control transmits the signals to the system. Features of the Remote Control Display T-ON (Timer ON) Pad Displays all set contents when turned on. When the air conditioner is off, press T-ON Displays only the set temperature and time (timer on) to set it to turn on automatically when turned off. (using its previous settings)

Summary of the content on the page No. 6

Care and cleaning of the air conditioner. CAUTION: Before performing any maintenance, turn off the main power to the system. Indoor Unit Grille, Case and Remote Control Air Filters The two air filters behind the front grille should be Turn the system off before cleaning. To clean, checked and cleaned at least every 30 days or wipe with a soft, dry cloth. Do not use bleach more often, if necessary. or abrasives. Air intake vent Air outlet vent Open the front access panel. 1 Pull the filter tab

Summary of the content on the page No. 7

Operating Installation Safety Instructions Troubleshooting Tips Consumer Support Instructions Instructions GEAppliances.com Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. Air intake If clogged with dirt or debris, the heat exchanger vents and panel vents should be professionally cleaned. Air outlet NOTES: vent  Power supply must be disconnected before cleaning the outdoor unit.  Dirty or clogged coils will reduce the operating effici

Summary of the content on the page No. 8

Installation Mini Split-System Air Conditioners Instructions BEFORE YOU BEGIN ELECTRICAL REQUIREMENTS Read these instructions completely and carefully. • Be certain all wiring complies with local building codes and • NEC and that the supply voltage for this system is correct. IMPORTANT — Save these instructions for local inspector’s use. The system supply voltage is connected to the outdoor unit only. • IMPORTANT — Observe all governing codes • Check the rating nameplate on the side panel of o

Summary of the content on the page No. 9

Installation Instructions PARTS INCLUDED INSTALLATION DIMENSIONS • Mounting plate • Remote control • Sealer • Batteries AAA (2) • Screws (5 for 10,000 and • Drainage hose 14,000 BTU models/10 for • Insulation hose 20,000 BTU models) • Two (2) filters 6” or more space to the ceiling 6” or more 6” or more SUPPLIED BY INSTALLER space to space to the wall the wall Adapter: 1/4″ male flare with Schrader valve x 5/16″ female (1/2″-20UN) Wrapping 118” or more 79” or more OPTIONAL ACCESSORY KITS air

Summary of the content on the page No. 10

Installation Instructions Read these instructions completely and carefully; then follow step by step. 1 SELECT THE BEST LOCATION A B INDOOR UNIT OUTDOOR UNIT • Do not allow any heat or steam near the unit. • If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat • Select a location where there are no obstacles radiation from the condenser is not restricted. in front of the unit. • Ensure that the space around the back and sides • Make sure that con

Summary of the content on the page No. 11

Installation Instructions 2 INSTALLATION 4 1 INSTALL THE MOUNTING PLATE INSTALL THE CONNECTION TUBING • Always mount the mounting plate horizontally. • Connect the copper tubing with the relevant union tubes of the indoor unit and tighten the flare nut • Attach the mounting plate at the selected location of the connection tubes. with screws supplied with the unit. NOTE: Be careful when bending the connection • Be sure that the mounting plate has been tubes to avoid damaging them. attached firm

Summary of the content on the page No. 12

Installation Instructions 2 INSTALLATION (cont.) 5 6 CONNECT ELECTRICAL WIRING WIRE THE INDOOR UNIT (cont.) BETWEEN INDOOR AND OUTDOOR NOTE: Wiring must be done by a qualified electrician according to the local codes and regulations and UNITS this manual. The connecting wire should be correctly • All wiring should be rated appropriately for the connected to the circuit interface. current value listed on the rating plate. • The power supply should accommodate the rated 4-way voltage. terminal boa

Summary of the content on the page No. 13

Installation Instructions 2 INSTALLATION (cont.) 7 INSTALL THE INDOOR UNIT 7 INSTALL THE INDOOR UNIT (cont.) • Route the tubes and wiring from the right side of • Wrap the tubes and wiring and pull them through the indoor unit. Cut off the tailings from the the cut-off-tailings hole. chassis as necessary. 1. Cut off tailings 1 when routing the wiring only. Wrapping tape 2. Cut off tailings 1 and 2 (or tailings 1, 2 and 3) when routing both the wiring and tubing. 1 and Connection tubes 2 below

Summary of the content on the page No. 14

Installation Instructions 2 INSTALLATION (cont.) 8 WIRE THE OUTDOOR UNIT 8 WIRE THE OUTDOOR UNIT (cont.) 1. Open the cover of the outdoor unit. NOTES: • Wiring should be consistent with the above wiring 2. The connecting wire lead from the terminal board diagrams. of the indoor unit must be connected correctly. • Wiring must be correct. 3. The connecting wire should be a little longer so • Tighten the nut of the terminal board to keep the that it can be maintained easily. board secured. 6-way t

Summary of the content on the page No. 15

Installation Instructions 2 INSTALLATION (cont.) 10 INSTALL THE OUTDOOR UNIT 11 PURGE THE AIR AND TEST FOR LEAKAGE • Install the connection tube 1. Align the center of the tubing flare with the 1. Install the connecting tubes of the relevant valve. indoor/outdoor unit. 2. Screw in the flare nut by hand and then tighten 2. DO NOT OPEN THE GAS VALVES UNTIL THE the nut with spanner and torque wrench. See EVACUATION PROCESS IS COMPLETE. the table below for the correct torque. 3. Remove the gas li

Summary of the content on the page No. 16

Installation Instructions TEST OPERATION AND CHECK AFTER INSTALLATION 13 Test operation 1. Before test operation • Do not switch on power before installation is finished completely. • Electrical wiring must be connected correctly and securely. • Shut-off valves of the connection tubes should be opened. • All impurities such as scraps and particulates must be cleared from the unit. 2. Test operation method • Switch on power and press the ON/OFF pad on the remote control to turn on the air conditi

Summary of the content on the page No. 17

Operating Installation Safety Instructions Troubleshooting Tips Consumer Support Instructions Instructions Before you call for service… GEAppliances.com Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do The system The fuse is blown/circuit • Check the house fuse/circuit breaker box and does not start breaker is tripped. replace the fuse or reset the breaker. The Timer operation is not set • Check

Summary of the content on the page No. 18

Split System Warranty. All warranty service provided by our designated service network. Staple your receipt here. To schedule service, call 866.404.5245. For service in Canada, contact Proof of the original purchase Gordon Williams Corp. at 1.888.209.0999. Please have serial number date is needed to obtain service and model number availa ble when calling for service. under the warranty. For The Period Of: GE Will Replace: One Year Any part of the air conditioner which fails due to a defect in

Summary of the content on the page No. 19

Consignes Consignes Instructions Conseils de Assistance de sécurité d’Utilisation de montage dépannage à la clientèle Consignes de sécurité . . . . . . . . . . . 20 Consignes d’utilisation Entretien et nettoyage . . . . . . . . . . . . . . . . .24 Fonctions de la télécommande . . . . 22, 23 Piles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Instructions de montage Avant de commencer . . . . . . . . . . . . . . . . .25 Branchements . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 20

IMPORTANTES CONSIGNES DE SÉCURITÉ. VEUILLEZ LIRE TOUTES LES CONSIGNES AVANT UTILISATION. AVERTISSEMENT! Pour votre sécurité, les informations contenues dans ce manuel doivent être suivies afin de minimiser les risques d’incendie, de chocs électriques ou de blessures corporelles. CONSIGNES DE SÉCURITÉ  N’utilisez cet appareil qu’aux fins prévues  La maintenance doit être effectuée par décrites dans le manuel d’utilisation. un technicien qualifié.  Ce système doit être correctement installé 


Alternative user manuals
# User manual Category Download
1 GE 10 ACB AJCQ 10 User manual Air Conditioner 292
2 GE 12 DCA User manual Air Conditioner 137
3 GE 10 DCA User manual Air Conditioner 26
4 GE 10 DCB User manual Air Conditioner 15
5 GE 23-11-2129N-002 User manual Air Conditioner 30
6 GE 12 DCB AJCQ 08 User manual Air Conditioner 26
7 GE 10 ACB AJCS 09 User manual Air Conditioner 5
8 GE 10 AZA User manual Air Conditioner 3
9 GE 2500 User manual Air Conditioner 38
10 GE 2900 User manual Air Conditioner 10
11 GE 3500 User manual Air Conditioner 38
12 GE 3800 User manual Air Conditioner 9
13 GE 3900 User manual Air Conditioner 12
14 GE 49-7400 User manual Air Conditioner 4
15 GE 49218 User manual Air Conditioner 5
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21