GE 49218 user manual

User manual for the device GE 49218

Device: GE 49218
Category: Air Conditioner
Manufacturer: GE
Size: 1.86 MB
Added : 5/20/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE 49218. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE 49218.

For your convenience

If looking through the GE 49218 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE 49218 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE 49218 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE 49218 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE 49218 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE 49218. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Answers at your fingertips
®
GE Answer Center
saves you time by providing answers
on product features.
800.626.2000
ge.com
—features
—installation instructions
—models
—use & care manuals
—specifications
—warranty
Quick Specs
Product features and dimensions are faxed to you
FREE, wherever and whenever you need them.
800.432.3729
A nationwide network of sales professionals and
service technicians wholly dedicated to the builder
community.
800.GE.CARES (800 432 2737)
GECustomerN

Summary of the content on the page No. 2

® Vertical Zoneline units Vertical Zoneline units RAVRMS (AZ Series*—7500) Wall-Mounted Room Air Sensor • Wall-mounted room air sensor provides Temperature ™ Limiting and Freeze Sentinel capability. • Includes  -meter conductor wire for hook-up to Vertical Zoneline. • Required for Motion Sensor/Door Switch applications. RAVWP6 (AZ Series*—7500) Wall Plenum • Wall Plenum for installation in walls less than 6" thick. • Wall Plenum 19- /4" x  2". • Wall cutout dimensions 20" x  2-1/4"

Summary of the content on the page No. 3

® Vertical Zoneline units Vertical Zoneline units RAVRMS (AZ Series*—7500) Wall-Mounted Room Air Sensor • Wall-mounted room air sensor provides Temperature ™ Limiting and Freeze Sentinel capability. • Includes  -meter conductor wire for hook-up to Vertical Zoneline. • Required for Motion Sensor/Door Switch applications. RAVWP6 (AZ Series*—7500) Wall Plenum • Wall Plenum for installation in walls less than 6" thick. • Wall Plenum 19- /4" x  2". • Wall cutout dimensions 20" x  2-1/4"

Summary of the content on the page No. 4

® Vertical Zoneline units RAVWP15 (AZ Series*—7500) RAVRG2 (AZ Series*—7500) Wall Plenum Return Air Grille • Wall Plenum for installation in walls less than 15" thick. • Return Air Grille for installation in common wall to closet. • Wall Plenum 19- /4" x  2". • Exterior dimensions 22-1/2" x 22-1/2". • Wall cutout dimensions 20" x  2-1/4". • Wall cutout dimension 20- /8" x 20- /8". • Warm gray beige color. • Accepts 20" x 20" x 1" field-supplied filter. • Warm gray beige color. † RAK5

Summary of the content on the page No. 5

® Vertical Zoneline units RAVWP15 (AZ Series*—7500) RAVRG2 (AZ Series*—7500) Wall Plenum Return Air Grille • Wall Plenum for installation in walls less than 15" thick. • Return Air Grille for installation in common wall to closet. • Wall Plenum 19- /4" x  2". • Exterior dimensions 22-1/2" x 22-1/2". • Wall cutout dimensions 20" x  2-1/4". • Wall cutout dimension 20- /8" x 20- /8". • Warm gray beige color. • Accepts 20" x 20" x 1" field-supplied filter. • Warm gray beige color. † RAK5

Summary of the content on the page No. 6

® Zoneline units Zoneline units RAB71A (All Zoneline Series) Standard Wall Case The RAB71A is a galvanized steel wall sleeve with expanded polystyrene foam insulation. It is welded and protected with baked-on enamel. Welded areas are protected with a sealing compound to prevent rust. The RAB71 wall case accepts all Zoneline chassis models. RAB77A4 (All Zoneline Series) SMC Wall Case The Zoneline SMC universally designed wall case by GE utilizes a fiberglass-reinforced polyester compoun

Summary of the content on the page No. 7

® Zoneline units Zoneline units RAB71A (All Zoneline Series) Standard Wall Case The RAB71A is a galvanized steel wall sleeve with expanded polystyrene foam insulation. It is welded and protected with baked-on enamel. Welded areas are protected with a sealing compound to prevent rust. The RAB71 wall case accepts all Zoneline chassis models. RAB77A4 (All Zoneline Series) SMC Wall Case The Zoneline SMC universally designed wall case by GE utilizes a fiberglass-reinforced polyester compoun

Summary of the content on the page No. 8

® Zoneline units Zoneline units RAF453 (AZ Series*—2800,  800 and 5800 only) RAK40 (AZ Series*) Replacement Standard Room Cabinet Air Deflector Kit Room cabinet with wrap-around design has attractive Kit adapts AZ chassis for use with older GE architectural grilles. textured finish which matches unit sleeve. Cabinet is injection- The aluminum deflectors are installed to the condenser end molded of high-impact polystyrene. Cabinet fastens to chassis sheet flanges to prevent condenser airflow

Summary of the content on the page No. 9

® Zoneline units Zoneline units RAF453 (AZ Series*—2800,  800 and 5800 only) RAK40 (AZ Series*) Replacement Standard Room Cabinet Air Deflector Kit Room cabinet with wrap-around design has attractive Kit adapts AZ chassis for use with older GE architectural grilles. textured finish which matches unit sleeve. Cabinet is injection- The aluminum deflectors are installed to the condenser end molded of high-impact polystyrene. Cabinet fastens to chassis sheet flanges to prevent condenser airflow

Summary of the content on the page No. 10

® Zoneline units Zoneline units Chaseway RAK7012 (AZ Series*—2200, 2500,  200,  500, RAK204 (AZ Series*—2200, 2500,  200 and  500 only) 8- /8" 2800 and  800 only) Standard Sub-Base Duct Adapter for Replacement of The RAK204 sub-base is made of heavy-gauge steel to provide support of the wall case. It has full base enclosure with break-away side channels, simple A-B with Rounded Front AZ Chassis Power cord and junction box connection to wall case, and 4-point leveling legs. The sub

Summary of the content on the page No. 11

® Zoneline units Zoneline units Chaseway RAK7012 (AZ Series*—2200, 2500,  200,  500, RAK204 (AZ Series*—2200, 2500,  200 and  500 only) 8- /8" 2800 and  800 only) Standard Sub-Base Duct Adapter for Replacement of The RAK204 sub-base is made of heavy-gauge steel to provide support of the wall case. It has full base enclosure with break-away side channels, simple A-B with Rounded Front AZ Chassis Power cord and junction box connection to wall case, and 4-point leveling legs. The sub

Summary of the content on the page No. 12

® Zoneline units Zoneline units † RAK4157/4207/4307 RAK4002B (AZ Series*—5500 and 5800 only) (AZ Series*—2800,  800, 5500, 5800 and 7500 only) Direct Connect Junction Box 230/208-Volt Universal Power Supply Kit (2 0/208 and 265/277 Volts) • 9-pin connector with three 7" 12-gauge conductor wires. RAK4002 junction box kit for permanent connection of 2 0/208- Circuit and 265/277-volt units to building power supply. Kit No. Volts Heater Wattage Ampacity Includes multi-circuit connector h

Summary of the content on the page No. 13

® Zoneline units Zoneline units † RAK4157/4207/4307 RAK4002B (AZ Series*—5500 and 5800 only) (AZ Series*—2800,  800, 5500, 5800 and 7500 only) Direct Connect Junction Box 230/208-Volt Universal Power Supply Kit (2 0/208 and 265/277 Volts) • 9-pin connector with three 7" 12-gauge conductor wires. RAK4002 junction box kit for permanent connection of 2 0/208- Circuit and 265/277-volt units to building power supply. Kit No. Volts Heater Wattage Ampacity Includes multi-circuit connector h

Summary of the content on the page No. 14

® Zoneline units Built-in units RAK806 Universal Cover Label (10 covers per kit) The RAK806 provides a cover for the control area to refer room occupant to use a remote thermostat. Double-sided tape provided. RAA62 (AZ Series*—2200,  200 and 5200 only) Replacement Filters for AZ Models (20 pairs per box) The up-front filters on the GE Zoneline unit are conveniently accessed by simply pulling them up from the top of the room cabinet. By simplifying the task, filter cleaning is more like

Summary of the content on the page No. 15

® Zoneline units Built-in units RAK806 Universal Cover Label (10 covers per kit) The RAK806 provides a cover for the control area to refer room occupant to use a remote thermostat. Double-sided tape provided. RAA62 (AZ Series*—2200,  200 and 5200 only) Replacement Filters for AZ Models (20 pairs per box) The up-front filters on the GE Zoneline unit are conveniently accessed by simply pulling them up from the top of the room cabinet. By simplifying the task, filter cleaning is more like

Summary of the content on the page No. 16

Built-in units Built-in units RAD4A1 Drain Kit RAG13 Stamped Aluminum Exterior Grille “J” Series Internal/External Drain Kit Used to replace exterior grille on old “J” wall case to maximize efficiency and capacity of new chassis. The grille is included Drain kit for use on “J” series wall cases. For more positive with new wall cases RAB46, 47, or 48. control of condensate water, the RAD4A1 drain kit routes condensate to the exterior or to the interior of the building through the wall case.

Summary of the content on the page No. 17

Built-in units Built-in units RAD4A1 Drain Kit RAG13 Stamped Aluminum Exterior Grille “J” Series Internal/External Drain Kit Used to replace exterior grille on old “J” wall case to maximize efficiency and capacity of new chassis. The grille is included Drain kit for use on “J” series wall cases. For more positive with new wall cases RAB46, 47, or 48. control of condensate water, the RAD4A1 drain kit routes condensate to the exterior or to the interior of the building through the wall case.

Summary of the content on the page No. 18

Built-in units Built-in units RAA72 Replacement Filter RAK1072 Hotpoint Chassis Sleeve Adapter for Rounded Front “J” Chassis Kit adapts Hotpoint ACXB 10 and ACXB 11 wall case (used with • Replacement filter for use in Room Fronts with ACTB chassis) to the sloped front or rounded front “J” chassis. 2 Round Control Knob openings ONLY. Existing case dimensions are 25- /4" W, 16-7/8" H, 18-5/8" D. • Washable/reusable nylon mesh filter. All needed gaskets and hardware, including the outdoor

Summary of the content on the page No. 19

Built-in units Built-in units RAA72 Replacement Filter RAK1072 Hotpoint Chassis Sleeve Adapter for Rounded Front “J” Chassis Kit adapts Hotpoint ACXB 10 and ACXB 11 wall case (used with • Replacement filter for use in Room Fronts with ACTB chassis) to the sloped front or rounded front “J” chassis. 2 Round Control Knob openings ONLY. Existing case dimensions are 25- /4" W, 16-7/8" H, 18-5/8" D. • Washable/reusable nylon mesh filter. All needed gaskets and hardware, including the outdoor

Summary of the content on the page No. 20

Thermostats—Heat pump Thermostats—Electric Resistance Heat RAK147 (A-B, AZ, and AZR Series*) RAK163A1 (A-B, AZ, and AZR Series*) Wall-Mounted Remote Thermostat Cooling with Electric Heat Remote Thermostat RAK147 is used with heat pump units. Units have integral RAK16 A1 is used with resistance heat models. Units have low-voltage terminal board to connect with thermostat. integral low-voltage terminal board to connect with thermostat. Temperature, operation mode, and fan operation are cont


Alternative user manuals
# User manual Category Download
1 GE 10 ACB AJCQ 10 User manual Air Conditioner 292
2 GE 12 DCA User manual Air Conditioner 137
3 GE 10 DCA User manual Air Conditioner 26
4 GE 10 DCB User manual Air Conditioner 15
5 GE 23-11-2129N-002 User manual Air Conditioner 30
6 GE 12 DCB AJCQ 08 User manual Air Conditioner 26
7 GE 10 ACB AJCS 09 User manual Air Conditioner 5
8 GE 10 AZA User manual Air Conditioner 3
9 GE 2500 User manual Air Conditioner 38
10 GE 2900 User manual Air Conditioner 10
11 GE 3500 User manual Air Conditioner 38
12 GE 3800 User manual Air Conditioner 9
13 GE 3900 User manual Air Conditioner 12
14 GE 49-7400 User manual Air Conditioner 4
15 GE 5500 User manual Air Conditioner 35
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21