Tripp Lite PowerVerter 93-1911 user manual

User manual for the device Tripp Lite PowerVerter 93-1911

Device: Tripp Lite PowerVerter 93-1911
Category: Power Supply
Manufacturer: Tripp Lite
Size: 1 MB
Added : 8/29/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Tripp Lite PowerVerter 93-1911. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Tripp Lite PowerVerter 93-1911.

For your convenience

If looking through the Tripp Lite PowerVerter 93-1911 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Tripp Lite PowerVerter 93-1911 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Tripp Lite PowerVerter 93-1911 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Tripp Lite PowerVerter 93-1911 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Tripp Lite PowerVerter 93-1911 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Tripp Lite PowerVerter 93-1911. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 1
Owner’s Manual
®
APS PowerVerter
1111 W. 35th Street
Chicago, IL 60609 USA
Alternative Power Sources
Customer Support: (773) 869-1234
www.tripplite.com
(120V, 60 Hz)
 Voltage- and Frequency-Controlled
 Peak Power, High Efficiency
Español: pg. 16
Introduction: p. 2 - 3
Safety: p. 4
Configuration & Connection: p. 5-10
Features: p. 10 - 11
Maintenance & Service: p. 12
Warranty: p. 12
Troubleshooting: p. 13
Specifications: p

Summary of the content on the page No. 2

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 2 Introduction Congratulations! You’ve purchased the most advanced, feature-rich integrated inverter/battery charger on the market. Your APS provides your equipment with utility-supplied AC power when it is available, and during blackouts, overvoltages and brownouts, your APS automatically switches over to an external battery source to power connected equipment with voltage and frequency- controlled AC power. In addition to r

Summary of the content on the page No. 3

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 3 Advanced, 3-Stage Battery Charger Stage 2 Absorption Your APS recharges your battery faster than conventional chargers because its three-stage charger pro- Stage 3 file (Bulk, Absorption and Float) are Float optimized, regardless of the type of battery you use (Wet or Gel).* In addi- tion, the advanced charging system protects against over-charge and over-discharge to ensure a longer service life from your battery. *The

Summary of the content on the page No. 4

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 4 Safety This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite APS Systems. APS Location Warnings  Install your APS indoors, away from excess moisture or heat, dust or direct sunlight.  Your APS is NOT waterproof. Contact with water can cause the unit to short circuit and could cause personal injury due to electric shock. Never immer

Summary of the content on the page No. 5

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 5 Configuration CONFIGURATION DIP SWITCH SETTINGS DIP SWITCH GROUP A (All models) BATTERY TYPE / VOLTAGE POINT Using a small tool, set the 4 “Battery Type / Voltage Point” Configuration DIP Switches, Group A (located on the front panel of your APS; see Diagram 1, p. 32) to select battery type and set the voltage range outside of which your APS will switch to battery power.  Select Battery Type (DIP Switch #1, Group A) CAUTIO

Summary of the content on the page No. 6

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 6  Load Sharing (DIP Switches #1, Group B & #2, Group B) Your APS features a high-output battery charger that can draw a significant amount of power from your line power source when charging at its maximum rate. If an APS is supplying its full AC power rating to its connected load at the same time as it is charging, it could trip its line source circuit breaker. Tripping this breaker will cut off AC power to your load and st

Summary of the content on the page No. 7

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 7  Limit Battery Charger (APS 1012 and APS 2012 only) (DIP Switch #4, Group B) To prevent overheating smaller batteries, the charger on these UPS systems is initially set to deliver only a fraction of its maximum power rating to connected batteries. If you are using either of these APS systems with a larger battery or battery system (over 100 amp-hours at 12 volts for the APS 1012, over 200 amp-hours at 12 volts for the APS

Summary of the content on the page No. 8

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 8 Mounting (Optional*) (See Diagram 2, p. 32). User must supply all fasteners and brackets and verify their suitability for use with the intended mounting surface. Turn your APS PowerVerter and connected equipment OFF before mounting.  Install two 8 mm (1/4 in.) fasteners (A) into a rigid horizontal surface using the measurements in the diagram. Leave the heads of fasteners raised slightly above the surface in order to engag

Summary of the content on the page No. 9

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 9 vehicular battery connection. Choose the Basic Connection if you are running light hand tools or other small appliances for a brief period of time (see Diagram 7, p. 34). Choose the Advanced Connection if you are using your APS to power heavy loads for extended periods of time (see Diagram 8, p. 34). The Advanced Connection incorporates a battery isolator and separate battery system to provide battery power to your APS whil

Summary of the content on the page No. 10

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 10 Set Operating Mode Switch continued  Switch to “CHARGE ONLY” when you are not using connected equipment. (WARNING! APS will not provide battery backup!) ADVANTAGES: A) Continues to charge battery when power is present, and B) Turns OFF the APS’s inverter, preventing battery drain during blackouts or brownouts.  Switch to “OFF” to completely turn off the APS and connected equipment or to reset the APS after it has shut

Summary of the content on the page No. 11

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 11 8. “BATTERY HI/MED/LO” (All models) These three lights will turn ON in several sequences to show the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions: BATTERY CHARGE INDICATION (Approximate) Indicator Capacity Green 91% - Full Green & yellow 81% - 90% Yellow 61% - 80% Yellow & red 41% - 60% Red 21% - 40% All three lights off 1% - 20% Flashing red 0% (Inverter shu

Summary of the content on the page No. 12

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 12 Maintenance & Service Maintenance Your APS model requires no maintenance but should be kept dry at all times. Periodically check all cable connections both at the unit and at the battery. Clean and tighten connections as necessary. Service If returning your APS to Tripp Lite, please pack the APS carefully, using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem.

Summary of the content on the page No. 13

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 13 Troubleshooting Try these remedies for common APS problems before calling for help. Call Tripp Lite Customer Service at (773) 869-1234 before returning your APS for service. SYMPTOM PROBLEMS CORRECTIONS APS does not provide APS not properly connected to Connect APS to utility power. AC output (AC input present) utility power. Circuit breaker is tripped. Reset circuit breaker. APS shutdown due to excessive Turn APS “OFF”. W

Summary of the content on the page No. 14

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 14 Specifications (Corded Models) CORDED MODELS: APS 1012 APS 1024 Weight: 26.4 lbs. 26.4 lbs. INVERTER Continuous power (@ 20° C): 900 W 1000 W Surge power (5 seconds): 1800 W 2000 W Efficiency (Full Load): 90% 90% Minimum DC Fuse Rating: 225A 125A DC Input Current @ Nominal V DC Full Load 95 A 47 A No Load 2.2 A* 1.3 A* Nominal Input Volts: 12 VDC 24 VDC DC Input Voltage Range: 10-15 VDC 20-30 VDC Nominal Output Volts: 1

Summary of the content on the page No. 15

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 15 Specifications (Hardwired Models) HARDWIRED MODELS: APS 2012 APS2424 Weight: 38.0 lbs. 41.0 lbs. INVERTER Continuous power (@ 20° C): 2000 W 2400 W Surge power (5 seconds): 4000 W 4800 W Efficiency (Full Load): 90% 90% Minimum DC Fuse Rating: 500A 300A DC Input Current @ Nominal V DC Full Load 192 A 112 A No Load 2.5 A* 1.5 A* Nominal Input Volts: 12 VDC 24 VDC DC Input Voltage Range: 10-15 VDC 20-30 VDC Nominal Output

Summary of the content on the page No. 16

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 32 Diagrams/Esquemas 1.1 1.2 1 See “Configuration”, pg. 5. 1.1 is DIP Switch Group A. 1.2 is DIP Switch Group B. Refiérase a la sección “Configuración”, página 20. 1.1 representa el Grupo A de Interruptores DIP. 1.2 representa el Grupo B de Interruptores DIP 2 3 3.3 3.4 3.5 3.6 3.7 3.2 3.1 See Hardwire Electrical Connections, pg. 9. 3.1 is the cover plate, 3.2 is the five-position terminal strip, 3.3 is the output neutral (wh

Summary of the content on the page No. 17

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 33 4 4.1 X Volts APS See Battery Connection, Pg.8. 4.1 is the fuse. X = Your APS's Inverter's Nominal Input Voltage. (See specs.) Refiérase a la sección “Conexión de Baterías”, página 23. 4.1 representa el fusible. X = El Voltaje Nominal de Entrada del Inversor del APS. (Vea las especificaciones). 5 5.1 APS X Volts X Volts X Volts X Volts See Battery Connection, Pg.8. 5.1 is the fuse. X = Your APS’s Inverter's Nominal Input V

Summary of the content on the page No. 18

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 34 7 7.1 12V 7.4 7.3 7.2 APS Basic 12VDC Vehicular Battery Connection. See Pg.8. 7.1 is the alternator. 7.2 is the vehicle battery ground. 7.3 is the vehicle battery. 7.4 is the fuse. Conexión Básica de Baterías de 12V de CD en Vehículos. Vea página 23. 7.1 representa el alternador. 7.2 representa la conexión a tierra de la batería del vehículo. 7.3 representa la batería del vehículo. 7.4 representa el fusible. 8 12V 8.6 8.1

Summary of the content on the page No. 19

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 35 2 8 14 4 5 6 1 9 15 A. Corded Model Modelo con Cable 13 16 9 11 10 B. Hardwired Model 7 3 2 8 14 4 5 61 Modelo con Toma Directa al Circuito 15 13 1. Interruptor “Operating Mode” (Modo de operación) 2. Grupo A de Interruptores DIP (Todos los modelos) 12 3. Grupo B de Interruptores DIP (Modelos selectos únicamente) 4. “LINE” (Línea) (Todos los modelos) 5. “INV” (Inversor ) (Todos los modelos) 6. “LOAD” (Carga Conectada) 9 7

Summary of the content on the page No. 20

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 36 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 www.tripplite.com 93-1911 (200103046) 36


Alternative user manuals
# User manual Category Download
1 Tripp Lite 120 User manual Power Supply 9
2 Tripp Lite 120V User manual Power Supply 26
3 Tripp Lite 1500RMXL2UA User manual Power Supply 15
4 Tripp Lite 120V Input, Line-Interactive UPS System SMART750USB User manual Power Supply 20
5 Tripp Lite 200305107 User manual Power Supply 0
6 Tripp Lite 1400VA User manual Power Supply 7
7 Tripp Lite 1500SLT User manual Power Supply 8
8 Tripp Lite 200204171 93-2036_EN User manual Power Supply 1
9 Tripp Lite 200904140 User manual Power Supply 1
10 Tripp Lite 200803016 95-2924 User manual Power Supply 1
11 Tripp Lite 2009XXXXX 93-1350_EN User manual Power Supply 1
12 Tripp Lite 220 User manual Power Supply 5
13 Tripp Lite 20KVA User manual Power Supply 10
14 Tripp Lite 2-Port In-Line PS/2 KVM Switch with Audio B032-002-R User manual Power Supply 11
15 Tripp Lite 240 User manual Power Supply 2
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2