Summary of the content on the page No. 1
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 1
Owner’s Manual
®
APS PowerVerter
1111 W. 35th Street
Chicago, IL 60609 USA
Alternative Power Sources
Customer Support: (773) 869-1234
www.tripplite.com
(120V, 60 Hz)
Voltage- and Frequency-Controlled
Peak Power, High Efficiency
Español: pg. 16
Introduction: p. 2 - 3
Safety: p. 4
Configuration & Connection: p. 5-10
Features: p. 10 - 11
Maintenance & Service: p. 12
Warranty: p. 12
Troubleshooting: p. 13
Specifications: p
Summary of the content on the page No. 2
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 2 Introduction Congratulations! You’ve purchased the most advanced, feature-rich integrated inverter/battery charger on the market. Your APS provides your equipment with utility-supplied AC power when it is available, and during blackouts, overvoltages and brownouts, your APS automatically switches over to an external battery source to power connected equipment with voltage and frequency- controlled AC power. In addition to r
Summary of the content on the page No. 3
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 3 Advanced, 3-Stage Battery Charger Stage 2 Absorption Your APS recharges your battery faster than conventional chargers because its three-stage charger pro- Stage 3 file (Bulk, Absorption and Float) are Float optimized, regardless of the type of battery you use (Wet or Gel).* In addi- tion, the advanced charging system protects against over-charge and over-discharge to ensure a longer service life from your battery. *The
Summary of the content on the page No. 4
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 4 Safety This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite APS Systems. APS Location Warnings Install your APS indoors, away from excess moisture or heat, dust or direct sunlight. Your APS is NOT waterproof. Contact with water can cause the unit to short circuit and could cause personal injury due to electric shock. Never immer
Summary of the content on the page No. 5
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 5 Configuration CONFIGURATION DIP SWITCH SETTINGS DIP SWITCH GROUP A (All models) BATTERY TYPE / VOLTAGE POINT Using a small tool, set the 4 “Battery Type / Voltage Point” Configuration DIP Switches, Group A (located on the front panel of your APS; see Diagram 1, p. 32) to select battery type and set the voltage range outside of which your APS will switch to battery power. Select Battery Type (DIP Switch #1, Group A) CAUTIO
Summary of the content on the page No. 6
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 6 Load Sharing (DIP Switches #1, Group B & #2, Group B) Your APS features a high-output battery charger that can draw a significant amount of power from your line power source when charging at its maximum rate. If an APS is supplying its full AC power rating to its connected load at the same time as it is charging, it could trip its line source circuit breaker. Tripping this breaker will cut off AC power to your load and st
Summary of the content on the page No. 7
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 7 Limit Battery Charger (APS 1012 and APS 2012 only) (DIP Switch #4, Group B) To prevent overheating smaller batteries, the charger on these UPS systems is initially set to deliver only a fraction of its maximum power rating to connected batteries. If you are using either of these APS systems with a larger battery or battery system (over 100 amp-hours at 12 volts for the APS 1012, over 200 amp-hours at 12 volts for the APS
Summary of the content on the page No. 8
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 8 Mounting (Optional*) (See Diagram 2, p. 32). User must supply all fasteners and brackets and verify their suitability for use with the intended mounting surface. Turn your APS PowerVerter and connected equipment OFF before mounting. Install two 8 mm (1/4 in.) fasteners (A) into a rigid horizontal surface using the measurements in the diagram. Leave the heads of fasteners raised slightly above the surface in order to engag
Summary of the content on the page No. 9
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 9 vehicular battery connection. Choose the Basic Connection if you are running light hand tools or other small appliances for a brief period of time (see Diagram 7, p. 34). Choose the Advanced Connection if you are using your APS to power heavy loads for extended periods of time (see Diagram 8, p. 34). The Advanced Connection incorporates a battery isolator and separate battery system to provide battery power to your APS whil
Summary of the content on the page No. 10
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 10 Set Operating Mode Switch continued Switch to “CHARGE ONLY” when you are not using connected equipment. (WARNING! APS will not provide battery backup!) ADVANTAGES: A) Continues to charge battery when power is present, and B) Turns OFF the APS’s inverter, preventing battery drain during blackouts or brownouts. Switch to “OFF” to completely turn off the APS and connected equipment or to reset the APS after it has shut
Summary of the content on the page No. 11
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 11 8. “BATTERY HI/MED/LO” (All models) These three lights will turn ON in several sequences to show the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions: BATTERY CHARGE INDICATION (Approximate) Indicator Capacity Green 91% - Full Green & yellow 81% - 90% Yellow 61% - 80% Yellow & red 41% - 60% Red 21% - 40% All three lights off 1% - 20% Flashing red 0% (Inverter shu
Summary of the content on the page No. 12
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 12 Maintenance & Service Maintenance Your APS model requires no maintenance but should be kept dry at all times. Periodically check all cable connections both at the unit and at the battery. Clean and tighten connections as necessary. Service If returning your APS to Tripp Lite, please pack the APS carefully, using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem.
Summary of the content on the page No. 13
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 13 Troubleshooting Try these remedies for common APS problems before calling for help. Call Tripp Lite Customer Service at (773) 869-1234 before returning your APS for service. SYMPTOM PROBLEMS CORRECTIONS APS does not provide APS not properly connected to Connect APS to utility power. AC output (AC input present) utility power. Circuit breaker is tripped. Reset circuit breaker. APS shutdown due to excessive Turn APS “OFF”. W
Summary of the content on the page No. 14
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 14 Specifications (Corded Models) CORDED MODELS: APS 1012 APS 1024 Weight: 26.4 lbs. 26.4 lbs. INVERTER Continuous power (@ 20° C): 900 W 1000 W Surge power (5 seconds): 1800 W 2000 W Efficiency (Full Load): 90% 90% Minimum DC Fuse Rating: 225A 125A DC Input Current @ Nominal V DC Full Load 95 A 47 A No Load 2.2 A* 1.3 A* Nominal Input Volts: 12 VDC 24 VDC DC Input Voltage Range: 10-15 VDC 20-30 VDC Nominal Output Volts: 1
Summary of the content on the page No. 15
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 15 Specifications (Hardwired Models) HARDWIRED MODELS: APS 2012 APS2424 Weight: 38.0 lbs. 41.0 lbs. INVERTER Continuous power (@ 20° C): 2000 W 2400 W Surge power (5 seconds): 4000 W 4800 W Efficiency (Full Load): 90% 90% Minimum DC Fuse Rating: 500A 300A DC Input Current @ Nominal V DC Full Load 192 A 112 A No Load 2.5 A* 1.5 A* Nominal Input Volts: 12 VDC 24 VDC DC Input Voltage Range: 10-15 VDC 20-30 VDC Nominal Output
Summary of the content on the page No. 16
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 32 Diagrams/Esquemas 1.1 1.2 1 See “Configuration”, pg. 5. 1.1 is DIP Switch Group A. 1.2 is DIP Switch Group B. Refiérase a la sección “Configuración”, página 20. 1.1 representa el Grupo A de Interruptores DIP. 1.2 representa el Grupo B de Interruptores DIP 2 3 3.3 3.4 3.5 3.6 3.7 3.2 3.1 See Hardwire Electrical Connections, pg. 9. 3.1 is the cover plate, 3.2 is the five-position terminal strip, 3.3 is the output neutral (wh
Summary of the content on the page No. 17
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 33 4 4.1 X Volts APS See Battery Connection, Pg.8. 4.1 is the fuse. X = Your APS's Inverter's Nominal Input Voltage. (See specs.) Refiérase a la sección “Conexión de Baterías”, página 23. 4.1 representa el fusible. X = El Voltaje Nominal de Entrada del Inversor del APS. (Vea las especificaciones). 5 5.1 APS X Volts X Volts X Volts X Volts See Battery Connection, Pg.8. 5.1 is the fuse. X = Your APS’s Inverter's Nominal Input V
Summary of the content on the page No. 18
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 34 7 7.1 12V 7.4 7.3 7.2 APS Basic 12VDC Vehicular Battery Connection. See Pg.8. 7.1 is the alternator. 7.2 is the vehicle battery ground. 7.3 is the vehicle battery. 7.4 is the fuse. Conexión Básica de Baterías de 12V de CD en Vehículos. Vea página 23. 7.1 representa el alternador. 7.2 representa la conexión a tierra de la batería del vehículo. 7.3 representa la batería del vehículo. 7.4 representa el fusible. 8 12V 8.6 8.1
Summary of the content on the page No. 19
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 35 2 8 14 4 5 6 1 9 15 A. Corded Model Modelo con Cable 13 16 9 11 10 B. Hardwired Model 7 3 2 8 14 4 5 61 Modelo con Toma Directa al Circuito 15 13 1. Interruptor “Operating Mode” (Modo de operación) 2. Grupo A de Interruptores DIP (Todos los modelos) 12 3. Grupo B de Interruptores DIP (Modelos selectos únicamente) 4. “LINE” (Línea) (Todos los modelos) 5. “INV” (Inversor ) (Todos los modelos) 6. “LOAD” (Carga Conectada) 9 7
Summary of the content on the page No. 20
200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 36 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 www.tripplite.com 93-1911 (200103046) 36