Delta Electronics AC Motor Drive VFD-G user manual

User manual for the device Delta Electronics AC Motor Drive VFD-G

Device: Delta Electronics AC Motor Drive VFD-G
Category: Power Supply
Manufacturer: Delta Electronics
Size: 4.75 MB
Added : 11/24/2013
Number of pages: 183
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Delta Electronics AC Motor Drive VFD-G. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Delta Electronics AC Motor Drive VFD-G.

For your convenience

If looking through the Delta Electronics AC Motor Drive VFD-G user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Delta Electronics AC Motor Drive VFD-G on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Delta Electronics AC Motor Drive VFD-G to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Delta Electronics AC Motor Drive VFD-G User manual - Online PDF
Advertisement
« Page 1 of 183 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Delta Electronics AC Motor Drive VFD-G but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Delta Electronics AC Motor Drive VFD-G. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Summary of the content on the page No. 4

Preface Thank you for choosing DELTA’s VFD-G Series for plastic molding and air compressors machinery. The VFD-G Series is manufactured with high-quality components and materials and incorporates the latest microprocessor technology available. This manual is to be used for the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drive. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC

Summary of the content on the page No. 5

WARNING! 1. DO NOT use Hi-pot test for internal components. The semi-conductor used in the AC motor drive is easily damaged by high-pressure. 2. There are highly sensitive MOS components on the printed circuit boards. These components are especially sensitive to static electricity. To prevent damage to these components, do not touch these components or the circuit boards with metal objects or your bare hands. 3. Only qualified persons are allowed to install, wire and maintain AC motor d

Summary of the content on the page No. 6

Table of Contents Preface ............................................................................................................. i Table of Contents .......................................................................................... iii Chapter 1 Introduction................................................................................ 1-3 1.1 Receiving and Inspection ................................................................... 1-3 1.1.1 Nameplate Information.....

Summary of the content on the page No. 7

2.3 Main Circuit Connection......................................................................2-3 2.4 Control Terminals ...............................................................................2-3 2.5 Specification for main circuit terminals and control terminals..............2-3 2.6 Wiring Explanation for Analog Input Terminal.....................................2-3 Chapter 3 Keypad and Start Up ..................................................................3-3 3.1 Digital Ke

Summary of the content on the page No. 8

5.9 Motor cannot Run............................................................................... 5-3 5.10 Motor Speed cannot be Changed..................................................... 5-3 5.11 Motor Stalls during Acceleration....................................................... 5-3 5.12 The Motor does not Run as Expected .............................................. 5-3 5.13 Electromagnetic/Induction Noise .....................................................

Summary of the content on the page No. 9

B.6.2 Explanation of Display Message.................................................B-3 B.6.3 PU06 Operation Flow Chart........................................................B-3 Appendix C How to Select the Right AC Motor Drive.............................. C-3 C.1 Capacity Formulas ............................................................................ C-3 C.2 General Precaution ........................................................................... C-3 C.3 How to Choose a Sui

Summary of the content on the page No. 10

Chapter 1 Introduction 1.1 Receiving and Inspection This VFD-G AC motor drive has gone through rigorous quality control tests at the factory before shipment. After receiving the AC motor drive, please check for the following: Check to make sure that the package includes an AC motor drive, the User Manual/Quick Start and CD, dust covers and rubber bushings. Inspect the unit to assure it was not damaged during shipment. Make sure that the part number indicated on the nameplate corresp

Summary of the content on the page No. 11

Chapter 1 Introduction | 1.1.3 Series Number Explanation 075F43AG4 T 7 01 0001 Production number 460V 3-PHASE 10HP(7.5kW) Production model If the nameplate information does not correspond to your purchase order or if there are any problems, please contact your distributor. 1.1.4 Drive Frames Frame Power Range Models VFD055F43B-G, VFD075F43B-G, VFD110F43A-G, C 7.5-20HP (5.5-15kW) VFD150F43A-G D 25-40HP (18.5-30kW) VFD185F43A-G, VFD220F43A-G, VFD300F43A-G E 50-75HP (37-55kW) VFD37

Summary of the content on the page No. 12

Chapter 1 Introduction | 50-125HP/37-90kW(Frame E, E1) 150-215HP/110-160kW(Frame G) 250-300HP/185-220kW(Frame H) Revision July 2008, EG03, SW V1.06 1-3

Summary of the content on the page No. 13

Chapter 1 Introduction | 1.3 Remove Instructions 1.3.1 Remove Keypad 7.5-20HP/5.5-15kW(Frame C) 25-40HP/18.5-30kW(Frame D) 50-125HP/37-90kW(Frame E, E1) 150-215HP/110-160kW(Frame G) 1-4 Revision July 2008, EG03, SW V1.06

Summary of the content on the page No. 14

Chapter 1 Introduction | 250-300HP/185-220kW(Frame H) 1.3.2 Remove Front Cover 7.5-20HP/5.5-15kW(Frame C) 25-40HP/18.5-30kW(Frame D) Revision July 2008, EG03, SW V1.06 1-5

Summary of the content on the page No. 15

Chapter 1 Introduction | 50-125HP/37-90kW(Frame E, E1) 150-215HP/110-160kW(Frame G) 250-300HP/185-220kW(Frame H) 1-6 Revision July 2008, EG03, SW V1.06

Summary of the content on the page No. 16

Chapter 1 Introduction | 1.4 Lifting Please carry only fully assembled AC motor drives as shown in the following. For 50-125HP (Frame E, E1) Step 1 Step 2 Step 3 Step 4 Revision July 2008, EG03, SW V1.06 1-7

Summary of the content on the page No. 17

Chapter 1 Introduction | For 150-215HP (Frame G) Step 1 Step 2 Step 3 Step 4 1-8 Revision July 2008, EG03, SW V1.06

Summary of the content on the page No. 18

Chapter 1 Introduction | For 250-300HP (Frame H) Step 1 Step 2 Step 3 Step 4 Revision July 2008, EG03, SW V1.06 1-9

Summary of the content on the page No. 19

Chapter 1 Introduction | 1.5 Preparation for Installation and Wiring 1.5.1 Ambient Conditions Install the AC motor drive in an environment with the following conditions: Air Temperature: -10 ~ +40°C (14 ~ 104°F) Relative Humidity: <90%, no condensation allowed Atmosphere 86 ~ 106 kPa Operation pressure: Installation Site <1000m Altitude: 2 <20Hz: 9.80 m/s (1G) max Vibration: 2 20 ~ 50Hz: 5.88 m/s (0.6G) max Temperature: -20°C ~ +60°C (-4°F ~ 140°F) Relative Humidity: <90%, no co

Summary of the content on the page No. 20

Chapter 1 Introduction | CAUTION! 1. Operating, storing or transporting the AC motor drive outside these conditions may cause damage to the AC motor drive. 2. Failure to observe these precautions may void the warranty! 3. Mount the AC motor drive vertically on a flat vertical surface object by screws. Other directions are not allowed. 4. The AC motor drive will generate heat during operation. Allow sufficient space around the unit for heat dissipation. 5. The heat sink temperature ma


Alternative user manuals
# User manual Category Download
1 Delta Electronics 0.75-3.3V User manual Power Supply 13
2 Delta Electronics 1Phase CliQ II DIN Rail DRP024V060W1BA User manual Power Supply 4
3 Delta Electronics 10A User manual Power Supply 0
4 Delta Electronics 4.5V~ 5.5V User manual Power Supply 1
5 Delta Electronics 1-phase 35W User manual Power Supply 0
6 Delta Electronics 3KVA User manual Power Supply 5
7 Delta Electronics 33W Family User manual Power Supply 0
8 Delta Electronics 20A User manual Power Supply 0
9 Delta Electronics 2.8-5.5Vin User manual Power Supply 0
10 Delta Electronics 700VA User manual Power Supply 0
11 Delta Electronics 4.5V~13.8Vin User manual Power Supply 0
12 Delta Electronics 7V ~ 13.2V User manual Power Supply 0
13 Delta Electronics AC Motor Drive VFD-E User manual Power Supply 23
14 Delta Electronics AC Motor Drive VFD-EL User manual Power Supply 608
15 Delta Electronics AC Motor Drive VFD-M User manual Power Supply 1352
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2