APC SYPM2KU user manual

User manual for the device APC SYPM2KU

Device: APC SYPM2KU
Category: Power Supply
Manufacturer: APC
Size: 1.04 MB
Added : 10/28/2013
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC SYPM2KU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC SYPM2KU.

For your convenience

If looking through the APC SYPM2KU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC SYPM2KU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC SYPM2KU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC SYPM2KU User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC SYPM2KU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC SYPM2KU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

APC Symmetra RM
Installation Manual
English
990-1031, Revision 1 8/00

Summary of the content on the page No. 2

Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase, except in India where the period is one year for battery module(s). Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support (see Serv

Summary of the content on the page No. 3

Table of Contents Chapter 1: Safety Information ............................................................. 1 Conventions Used in this Manual ......................................................... 1 Handling Safety..................................................................................... 1 Electrical Safety .................................................................................... 1 Deenergizing Safety....................................................................

Summary of the content on the page No. 4

List of Figures Figure 1: Symmetra RM..................................................................................................................................... 5 Figure 2: Front View of the Symmetra RM ....................................................................................................... 7 Figure 3: Rear View of the Symmetra RM (200/208 Vac / L1-L2-G version shown)....................................... 8 Figure 4: System Block Diagram ............................

Summary of the content on the page No. 5

CHAPTER 1: SAFETY INFORMATION This Safety section contains important instructions that should be followed during installation and maintenance of the APC equipment and batteries. It is intended for APC customers who setup, install, relocate, or maintain APC equipment. Connection to the branch circuit (mains) must be performed by a Licensed Electrician. Installation and removal of the Power, Battery, and Intelligence modules must be performed by service personnel. Installation and removal of in

Summary of the content on the page No. 6

• Use one hand, whenever possible, to connect or disconnect signal cables to avoid a possible shock from touching two surfaces with different electrical grounds. • Connect the equipment to a three wire AC outlet (two poles plus ground). The receptacle must be connected to appropriate branch circuit/mains protection (fuse or circuit breaker). Connection to any other type of receptacle may result in a shock hazard. • The protective earth conductor for the Symmetra RM carries the leakage current

Summary of the content on the page No. 7

Recycling of Batteries See your dealer or Replacing Modules in the SYMMETRA RM OPERATION MANUAL, for information on replacement battery kits and battery recycling. • Do not install the battery module(s) in the frame until you are ready to power up the Symmetra RM. Failure to so can result in a deep discharge of the batteries, which may cause permanent damage. • Store the battery module(s) in a cool ambient temperature of < 25 ° ° ° °C. Radio Frequency Interference This equipment has been tested

Summary of the content on the page No. 8

4

Summary of the content on the page No. 9

CHAPTER 2: BASICS About Your UPS The Symmetra RM is a high-performance, uninterruptible power system in a “power array” configuration, designed to power high availability servers and other sensitive electronic equipment. It provides conditioned, reliable AC power to connected equipment, and provides protection from power blackouts, brownouts, swells, sags, surges, and interference. The Symmetra RM is comprised of a frame and a variable set of modules. A system can be configured to deliver a max

Summary of the content on the page No. 10

How To Contact APC Internet http://www.apc.com/support North America Phone 1.800.800.4272 Fax 1.401.788.2743 Email apctech@apcc.com Latin America, South America Argentina.....0800.9.APCC (0800.9.2722) Mexico....................... 95.800.804.4283 Brazil ...........0800.12.72.21 Uruguay..................... 000.413.598.2139 Colombia .....980.15.39.47 Venezuela.................. 8001.2544 Europe, Middle East, and Africa Phone................+353 91 702020 Email...............apceurtech @ apcc.com

Summary of the content on the page No. 11

Product Overview Front View Component Identification              Figure 2: Front View of the Symmetra RM Power Module(s) : The Symmetra RM can support between one and four power modules. Each module provides 2 kVA/1.4 KW power. Redundant Intelligence Module : The redundant intelligence module (RIM) is a backup version of the main intelligence module(MIM). It provides redundancy in the event of a MIM failure or while a MIM is being replaced. Main Intelligence Module : The ma

Summary of the content on the page No. 12

Rear View Component Identification         Figure 3: Rear View of the Symmetra RM (200/208 Vac / L1-L2-G version shown) System Fan : The system fan can be replaced in the field. Refer to Replacing the System Fan, in the SYMMETRA RM OPERATION MANUAL, for instructions. Accessory Ports : APC manufactures a set of auxiliary user interface accessories. The Symmetra RM contains a total of three accessory ports. The top slot is preloaded with the SYCC card that provides computer and

Summary of the content on the page No. 13

Input Voltage Selection Switch : Set this switch to the appropriate setting, either 200/208 (L1-L2-G) or 220/230/240 (L1-N-G) before powering up the Symmetra RM. Products rated 200/208 are typically installed in North America (208 V, phase to phase, grounding conductor) and Japan (200V, phase to phase, grounding conductor). Products rated 2020/230/240 are typically installed in the rest of the world (220 V, 230 V, or 240 V, phase to neutral, protective earth). These products must be hard wire

Summary of the content on the page No. 14

System Block Diagram Accessory ACCESSORY PASS THROUGH BUS Cards DB9 COM Port PowerView Display External Battery Battery MIM RIM COM Card Frame Monitor COM Bus Power Module Battery Power or Module Battery 120 VDC Module Power or Battery Battery Module Module 120 VDC Power or Battery Battery Module Module 120 VDC Automatic External Battery Bypass Power AC in 155 to 276 VAC Backfeed Relay Input Circuit Breaker Manual Bypass Figure 4: System Block Diagram 10

Summary of the content on the page No. 15

CHAPTER 3: INSTALLATION Unpacking APC has taken care to design robust packaging for your product. However, accidents and damage may occur during shipment. Inspection Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Contents The shipping package contains the UPS, one PowerView display bezel, three blank bezels, the mounting rail kit (containing the mounting rails, and hardware), one blank

Summary of the content on the page No. 16

Determine the Location of the Symmetra RM in the Rack 1. Select a location for the Symmetra RM in your NetShelter enclosure or other 19-inch (46.5 cm) rack. Select a location with adequate air flow that is free from excessive dust. Ensure that the air vents on the sides of the Symmetra are not blocked. • The Symmetra RM is heavy. Select a rack location sturdy enough to handle the weight. Mount the unit at or near the bottom of the rack. • Do not operate the unit where temperature or humidity

Summary of the content on the page No. 17

Install the UPS into the Rack 1. With two people supporting the Symmetra RM, one on each side, carefully align the cleats on the sides of the unit with the grooves on the mounting rails. Slide the unit into the rack completely. 2. Use the six (6) ornamental screws, supplied with the unit, to attach the mounting brackets to the rack post. Connect the Symmetra RM to its Power Source 200/208/240 Vac (L1-L2-G) Symmetra RM: The input power can be supplied in two ways: the attached line cord can be

Summary of the content on the page No. 18

1. Make sure the main circuit breaker , located on the rear panel, is in the OFF position.  2. Select the appropriate wire size and connectors, according to local codes. For most applications, #10 AWG (5 sq. mm) wire should be sufficient. 3. Remove the input wiring access door by unscrewing the single   screw that holds the access panels in place. The input wiring terminal  is located on the rear panel of the Symmetra RM. 4. Use a screwdriver or any hard object to detach the circular knock

Summary of the content on the page No. 19

Use one of the following cable types to connect the Symmetra RM to the EPO switch: CL2 Class 2 cable for general use. CL2P Plenum cable for use in ducts, plenums, and other spaces used for environmental air. CL2R Riser cable for use in a vertical run in a shaft of from floor to floor. CL2X Limited use cable for use in dwellings and for use in raceway. For installation in Canada: Use only CSA Certified, type ELC (extra-low voltage control cable). Connection Option 1 An electrician must connect 1

Summary of the content on the page No. 20

Install battery modules just prior to running the Symmetra RM. The battery modules discharge slowly when loaded prematurely and can be damaged permanently. Each battery module weighs 21.8 kg (48 lbs). Two people are required to install or remove battery modules. Battery Module: With one person on either side of the battery module, lift the module, and slide it completely into the frame to engage the internal electrical connector. The top of each battery module has a tab to align the module c


Alternative user manuals
# User manual Category Download
1 APC 208 Vac User manual Power Supply 8
2 APC 1400XLT User manual Power Supply 23
3 APC 15A User manual Power Supply 0
4 APC 120V User manual Power Supply 5
5 APC 2200XLT User manual Power Supply 24
6 APC 2000XL User manual Power Supply 15
7 APC 1000VA User manual Power Supply 24
8 APC 1500 VA User manual Power Supply 46
9 APC 300 User manual Power Supply 404
10 APC 5000VA User manual Power Supply 60
11 APC 500 User manual Power Supply 26
12 APC 3000VA User manual Power Supply 12
13 APC 3000T User manual Power Supply 1
14 APC 600 User manual Power Supply 64
15 APC 2AP9604S User manual Power Supply 1
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2