Xantrex Technology XPH 35-4D user manual

User manual for the device Xantrex Technology XPH 35-4D

Device: Xantrex Technology XPH 35-4D
Category: Power Supply
Manufacturer: Xantrex Technology
Size: 0.59 MB
Added : 6/1/2013
Number of pages: 37
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Xantrex Technology XPH 35-4D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Xantrex Technology XPH 35-4D.

For your convenience

If looking through the Xantrex Technology XPH 35-4D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Xantrex Technology XPH 35-4D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Xantrex Technology XPH 35-4D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Xantrex Technology XPH 35-4D User manual - Online PDF
Advertisement
« Page 1 of 37 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Xantrex Technology XPH 35-4D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Xantrex Technology XPH 35-4D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




XPH 35-4D
XPH 35-4T
Operating Manual
XPH Series Dual
and Triple Output
35V 4A DC
Power Supply
www.programmablepower.com

Summary of the content on the page No. 2

About Xantrex Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power

Summary of the content on the page No. 3

Table of Contents Introduction 3 Specification 3 EMC 5 Safety 6 Installation 7 Connections 7 Operation - Main Outputs 8 Operation - Auxiliary Output 9 Operation - General 9 Calibration 10 Maintenance 12 Instructions en Francais Sécurité 13 Installation 14 Connexions 14 Fonctionnement - Sorties principales 15 Fonctionnement – Sortie Auxiliaire 16 Fonctionnement - Généralités 16 Maintenance 17 Bedienungsanleitung auf Deutsch Sicherheit 18 Installation 19 Anschlüsse 19 Be

Summary of the content on the page No. 4

Introduction The XPH 35-4D and XPH 35-4Tv provide high levels of power (up to 305 watts) in a compact and attractive case style. High resolution controls allow precise setting of voltage and current levels which are indicated on accurate and legible digital meters. Excellent line and load regulation are matched by low noise and good transient response. High power efficiency ensures that the unit remains cool without any fan noise. The XPH 35-4D has two independent and isolated outputs

Summary of the content on the page No. 5

Transient Response: <200µs to within 50mV of set level for 90% load change. Temperature Coefficient: Typically <100ppm/°C. Status Indication: Output on lamp. Constant current mode lamp. METER SPECIFICATIONS (Main Outputs) Meter Types: Dual 3 digit meters with 14mm (0·56") LEDs. Reading rate 4 Hz. Meter Resolutions: 100mV, 10mA. Meter Accuracies: Voltage 0.3% of reading ± 1 digit, Current 0.6% of reading ± 1 digit. AUXILIARY LOGIC OUTPUT (XPH 35-4T only) Voltage: Variable <1·5V to

Summary of the content on the page No. 6

EMC This instrument has been designed to meet the requirements of the EMC Directive 89/336/EEC. Compliance was demonstrated by meeting the test limits of the following standards: Emissions EN61326 (1998) EMC product standard for Electrical Equipment for Measurement, Control and Laboratory Use. Test limits used were: a) Radiated: Class B b) Conducted: Class B c) Harmonics: EN61000-3-2 (2000) Class A; the instrument is Class A by product category. Immunity EN61326 (1998) EMC p

Summary of the content on the page No. 7

Safety This power supply is a Safety Class I instrument according to IEC classification and has been designed to meet the requirements of EN61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use). It is an Installation Category II instrument intended for operation from a normal single phase supply. This instrument has been tested in accordance with EN61010-1 and has been supplied in a safe condition. This instruction manual contains some inform

Summary of the content on the page No. 8

Installation Mains Operating Voltage This instrument has a universal input range and will operate from a nominal 115V or 230V mains supply without adjustment. Check that the local supply meets the AC Input requirement given in the Specification. Mains Lead When a three core mains lead with bare ends is provided this should be connected as follows: BROWN - MAINS LIVE BLUE - MAINS NEUTRAL GREEN/YELLOW - EARTH Safety Earth Symbol When fitting a fused plug a 5 amp fuse should

Summary of the content on the page No. 9

Operation - Main Outputs The operation of both main outputs is identical; the following description applies to both. Setting Up the Output With the POWER switch on (l) and the output OFF the output voltage and current limit can be accurately preset using the VOLTAGE and CURRENT controls; the left-hand meter shows the set voltage and the right-hand meter shows the set maximum current. When the output switch is switched ON, the lamp lights; the left-hand meter now shows the actual

Summary of the content on the page No. 10

Operation - Auxiliary Output Output Voltage The output voltage can be set between 1·5V and 5·0V using the front panel rotary adjustment beside the centre terminals. With the right-hand main output OFF, pressing the SHOW AUX PRESET button will display the AUX output voltage and current limit on the right-hand meters. Current Limit The output will go into current limit at between 5A and 6A; the UNREG lamp lights in this condition. Protection The output has intrinsic short-circuit pro

Summary of the content on the page No. 11

Calibration Allow at least 5 minutes warm-up before commencing calibration. Access to Calibration Adjustments All adjustments are on the front panel control board; all the trimmers are adjusted from the reverse side of the board through holes in the board. To gain access to the board it is necessary to remove the top cover. WARNING! When the instrument is connected to its supply the removal of covers is likely to expose live parts. The instrument should be disconnected from all volta

Summary of the content on the page No. 12

Current Calibration Switch output OFF. Set output voltage to nominally 2V. Set current control to minimum. Connect the DMM (set to Amps) and load in series across the output. Switch output ON. Adjust VR8/108 (offset compensation of current control error amp) for a reading of 0·003A ± ·001A on the DMM. Check that the CC LED is ON. Increase voltage controls and current control to maximum. Adjust load until the DMM reads 4·00A ± 0·02A. Adjust VR7/107 (measured output current) until the Amp

Summary of the content on the page No. 13

Maintenance The Manufacturers or their agents overseas will provide repair for any unit developing a fault. Where owner wish to undertake their own maintenance work, this should only be done by skilled personnel in conjunction with the service manual which may be purchased directly from the Manufacturers or their agents overseas. Fuse The correct fuse type is: 10 Amp 250V HBC time-lag(T), 5 x 20mm. Note that the main function of the fuse is to make the instrument safe and limit damage

Summary of the content on the page No. 14

Sécurité Cet instrument est de Classe de sécurité 1 suivant la classification IEC et il a été construit pour satisfaire aux impératifs EN61010-1 (impératifs de sécurité pour le matériel électrique en vue de mesure, commande et utilisation en laboratoire). Il s'agit d'un instrument d'installation Catégorie II devant être exploité depuis une alimentation monophasée habituelle. Cet instrument a été soumis à des essais conformément à EN61010-1 et il a été fourni en tout état de sécurité. C

Summary of the content on the page No. 15

Installation Tension d’utilisation secteur Cet instrument a une plage d'entrée universelle et il fonctionne sur une alimentation secteur de 115 V ou de 230 V, tension nominale, sans ajustement aucun. Vérifier que l'alimentation locale satisfait aux impératifs d'entrée c.a. indiqués aux Caractéristiques techniques. Câble secteur Relier de la manière suivante tout câble secteur à trois conducteurs à fils nus: MARRON - SECTEUR SOUS TENSION BLEU - SECTEUR NEUTRE VERT/JAUNE - TERR

Summary of the content on the page No. 16

Fonctionnement - Sorties principales Le fonctionnement des deux sorties principales est identique; la description suivante s’applique aux deux. Réglage de la sortie Lorsque l’interrupteur POWER (alimentation) est en position (l) et la sortie est en position OFF (éteinte), il est possible de régler avec précision la limite de tension et de courant de sortie au moyen des commandes VOLTAGE (Tension) et CURRENT (Courant); l’appareil de mesure gauche indique la tension réglée et l’apparei

Summary of the content on the page No. 17

Fonctionnement – Sortie Auxiliaire Tension de sortie La tension de sortie peut être réglée entre 1·5V et 5·0V en utilisant la commande rotative du panneau avant près des bornes centrales. Avec l'afficheur de l'état de la sortie principale droite, un appui sur le bouton SHOW AUX PRESET (montrer les réglages auxiliaire) provoquera l'affichage de la tension et de la limite du courant de la sortie auxiliaire sur l'afficheur droit. Limite de courant La sortie passe à la limite de courant c

Summary of the content on the page No. 18

Maintenance Le Constructeur ou ses agents à l'étranger répareront tout bloc qui tombe en panne. Si le propriétaire de l'appareil décide d'effectuer lui-même la maintenance, ceci doit uniquement être effectué par un personnel spécialisé qui doit se référer au manuel d’entretien que l'on peut se procurer directement auprès du Constructeur ou de ses agents à l'étranger. Fusible Type de fusible correct: 10A 250V HBC temporisé (T), 5 x 20 mm. Il faut noter que l’objet principal de ce fusib

Summary of the content on the page No. 19

Sicherheit Dieses Gerät wurde nach der Sicherheitsklasse (Schutzart) I der IEC-Klassifikation und gemäß den europäischen Vorschriften EN61010-1 (Sicherheitsvorschriften für elektrische Mess-, Steuer-, Regel- und Laboranlagen) entwickelt. Es handelt sich um ein Gerät der Installationskategorie II, das für den Betrieb von einer normalen einphasigen Versorgung vorgesehen ist. Das Gerät wurde gemäß den Vorschriften EN61010-1 geprüft und in sicherem Zustand geliefert. Die vorliegende Anlei

Summary of the content on the page No. 20

Installation Netzbetriebsspannung Das Gerät besitzt einen universellen Eingangsbereich und kann ohne jede weitere Einstellung mit einer Nenn-Netzversorgung von 115 oder 230 V betrieben werden. Stellen Sie sicher, daß die Versorgung am Ort den in der Spezifikation aufgeführten Eingangsanforderungen entspricht. Netzkabel Steht nur ein Netzkabel ohne Stecker zur Verfügung, so ist es wie folgt anzuschließen: BRAUN - STROMFÜHRENDER LEITER BLAU - NULLEITER GRÜN/GELB - SCHUTZLEITER


Alternative user manuals
# User manual Category Download
1 Xantrex Technology 230 VAC/50 User manual Power Supply 2
2 Xantrex Technology 40 A (XADC-40) User manual Power Supply 6
3 Xantrex Technology 18V 10A User manual Power Supply 1
4 Xantrex Technology 42V 10A User manual Power Supply 5
5 Xantrex Technology 500 User manual Power Supply 0
6 Xantrex Technology 300 PLUS User manual Power Supply 12
7 Xantrex Technology 60 A (XADC-60) User manual Power Supply 2
8 Xantrex Technology 600HD User manual Power Supply 0
9 Xantrex Technology 400R User manual Power Supply 1
10 Xantrex Technology ACCB User manual Power Supply 0
11 Xantrex Technology 700 PLUS User manual Power Supply 0
12 Xantrex Technology 80 A (XADC-80) User manual Power Supply 4
13 Xantrex Technology ACCB-L User manual Power Supply 0
14 Xantrex Technology ACCB-L-L1 User manual Power Supply 0
15 Xantrex Technology APG-XT User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2