Xantrex Technology XPD 120-4.5 user manual

User manual for the device Xantrex Technology XPD 120-4.5

Device: Xantrex Technology XPD 120-4.5
Category: Power Supply
Manufacturer: Xantrex Technology
Size: 0.96 MB
Added : 6/1/2013
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Xantrex Technology XPD 120-4.5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Xantrex Technology XPD 120-4.5.

For your convenience

If looking through the Xantrex Technology XPD 120-4.5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Xantrex Technology XPD 120-4.5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Xantrex Technology XPD 120-4.5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Xantrex Technology XPD 120-4.5 User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Xantrex Technology XPD 120-4.5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Xantrex Technology XPD 120-4.5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

XPD 7.5-67
XPD 18-30
XPD 33-16
XPD 60-9
XPD 120-4.5
Operating Manual
XPD 500 Watt Series
Programmable DC
Power Supply

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Operating Manual for XPD Series Programmable DC Power Supply

Summary of the content on the page No. 4

Limited What does this warranty cover and how long does it last? Warranty This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your XPD 500 Watt Series DC Power Supply. This warranty lasts for a Warranty Period of 5 years from the date of purchase at point of sale to you, the original end user customer. What will Xantrex do? Xantrex will, at its option, repair or replace the defective product free of charge, provided th

Summary of the content on the page No. 5

Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. In any warranty claim, dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantre

Summary of the content on the page No. 6

Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER’S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE),

Summary of the content on the page No. 7

Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT; AND b. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE

Summary of the content on the page No. 8

Warnings Warnings and cautions are defined and formatted in this manual as shown below. and Cautions WARNING Describes a potential hazard which could result in injury or death, or, a procedure which, if not performed correctly, could result in injury or death. CAUTION ! Describes a procedure which, if not performed correctly, could result in damage to data, equipment, or systems. Power Supply Safety WARNING—High Energy and High Voltage Exercise caution when using and calibrating a power supply

Summary of the content on the page No. 9

About This Manual This Operating Manual contains operating information for the XPD Series of high-performance, switching, laboratory power supplies, available in several voltage models at 500 watts. It provides information on features and specifications, installation procedures, and basic functions testing, as well as operating procedures for using both front panel control and remote analog programming functions. Who Should Use This Manual This manual is designed for the user who is familiar

Summary of the content on the page No. 10

About This Manual Power Supply Safety Markings Alternating Current Off (Supply) Earth (Ground) Terminal On (Supply) Caution (Check manual for Protective Conductor Terminal additional information.) viii Operating Manual for XPD Series Power Supply

Summary of the content on the page No. 11

Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Features and Features and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Specifications Front Panel Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 12

Section 3. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Local Standard Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Operation Operating Modes and Automatic Crossover . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Constant Voltage Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Constant Current Mode O

Summary of the content on the page No. 13

Section 1. Features and Specifications Description The XPD Series of DC power supplies provides stable, variable output voltage and current for a broad range of development and system requirements. The units use high-frequency soft-switching technology to achieve high power density and retain a small package size. They feature a built-in analog programming interface, with optional RS-232 and IEEE-488 controlled programming, making this series the first choice in flexible power system design

Summary of the content on the page No. 14

Section 1. Features and Specifications Front Panel Controls  This unit may be equipped with an optional internal GPIB or RS-232 control for remote digital programming and readback.  Remote output sensing provides load cable compensation up to 5 V/line (3 V/line for 7.5 V model).  A rack mount kit (Option RM) is also available for this product. Front Panel Controls See Figure 1.1 to review the displays, LEDs, indicators, and controls located on the power supply’s front panel. Check the foll

Summary of the content on the page No. 15

Section 1. Features and Specifications Rear Panel Connectors Rear Panel Connectors Remote Sensing Port: Remove Default Jumpers to Blank Sub-Plate: use Remote Sensing Replaced if Digital Programming Option is Installed Fan Exhaust Vents: Do not obstruct Analog Programming and Readback Busbar Cover Output Busbars IEC 320 AC Input Connector Figure 1.2 500 Watt Power Supply Rear Panel (7.5 V and 18 V) Remote Sensing Port: Remove Default Jumpers to use Remote Sensing DC Output Connector: 33 V,

Summary of the content on the page No. 16

Section 1. Features and Specifications Rear Panel Connectors Output Low Voltage Models Equipped with positive and negative busbars. The busbars are offset to facilitate load cable connections. Connectors WARNING Disconnect the AC input before making any connections to the unit. . Figure 1.4 Output Busbars - note polarity markings (Low Voltage Models) High Voltage Models High voltage models are equipped with a 4-terminal output block. The top two are positive terminals whereas the lower two are

Summary of the content on the page No. 17

Section 1. Features and Specifications Rear Panel Connectors Rear Panel The J210 Analog Interface connector is a 15-pin female DSUB connector located on the rear panel. See Figure 1.6. Use the J210 programming, monitoring, and J210 shutdown 15 pin DSUB connector for remote programming and monitoring Connector functions. See Figure 1.2 for the location of the J210 connector at the rear panel. We recommend that you mate the J210 connector with a 15-pin male connector, such as a Tyco 747908-2

Summary of the content on the page No. 18

Section 1. Features and Specifications Rear Panel Connectors Table 1.2 Rear Panel J210 Connector Pins and Functions Pin Reference Name Function 1 J210-1 TTL S/D Shutdown Signal Return Return for shutdown signal . RTN (−) 1 J210-2 TTL S/D Shutdown Input (+) Input for shutdown signal. J210-3 N/C No connection None. J210-4 N/C No connection None. J210-5 IPGM Output Current Limit Input for current limit programming Programming Input signals from an analog device. J210-6 VRMT Remote Output Voltage S

Summary of the content on the page No. 19

Section 1. Features and Specifications Rear Panel Connectors Making J210 Connections CAUTION ! Program/monitor signal and return are internally connected to the power supply negative output. Do not attempt to bias these away from that potential. CAUTION ! To maintain the isolation of the power supply output and prevent ground loops, use an isolated (ungrounded) programming source when operating the power supply via remote analog control at the J210 connector. CAUTION ! Before making connecti

Summary of the content on the page No. 20

Section 1. Features and Specifications Electrical Specifications Electrical Specifications These specifications are warranted over a temperature range of 0 °C to 50 °C with local sense. Above 50 °C, derate output linearly to zero at 70 °C. Nominal line voltages are 100/120/200/230/240 Vac. Specifications and characteristics refer to a single output model unless otherwise stated, and specifications apply to either front or rear outputs unless noted. Table 1.3 Electrical Specifications for 7.5


Alternative user manuals
# User manual Category Download
1 Xantrex Technology 230 VAC/50 User manual Power Supply 2
2 Xantrex Technology 40 A (XADC-40) User manual Power Supply 6
3 Xantrex Technology 18V 10A User manual Power Supply 1
4 Xantrex Technology 42V 10A User manual Power Supply 5
5 Xantrex Technology 500 User manual Power Supply 0
6 Xantrex Technology 300 PLUS User manual Power Supply 12
7 Xantrex Technology 60 A (XADC-60) User manual Power Supply 2
8 Xantrex Technology 600HD User manual Power Supply 0
9 Xantrex Technology 400R User manual Power Supply 1
10 Xantrex Technology ACCB User manual Power Supply 0
11 Xantrex Technology 700 PLUS User manual Power Supply 0
12 Xantrex Technology 80 A (XADC-80) User manual Power Supply 4
13 Xantrex Technology ACCB-L User manual Power Supply 0
14 Xantrex Technology ACCB-L-L1 User manual Power Supply 0
15 Xantrex Technology APG-XT User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2