Summary of the content on the page No. 4
Limited What does this warranty cover and how long does it last? Warranty This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your GPIB-M Interface Card. This warranty lasts for a Warranty Period of 5 years from the date of purchase at point of sale to you, the original end user customer. What will Xantrex do? Xantrex will, at its option, repair or replace the defective product free of charge, provided that you notify
Summary of the content on the page No. 5
Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. In any warranty claim, dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantre
Summary of the content on the page No. 6
Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER’S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE),
Summary of the content on the page No. 7
Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT; AND b. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE
Summary of the content on the page No. 8
Power Supply WARNING—High Energy and High Voltage Exercise caution when using and calibrating a power supply. High energy levels Safety can be stored at the output voltage terminals on a power supply in normal operation. In addition, potentially lethal voltages exist in the power circuit and on the output and sense connectors of a power supply with a rated output greater than 40 V. Filter capacitors store potentially dangerous energy for some time after power is removed. CAUTION ! Operate t
Summary of the content on the page No. 9
About This Manual This operating manual is for the internal Multichannel Interface (GPIB-M), a microprocessor-controlled option card for your DC output power supply. This manual provides you with descriptions and specifications, user options, and configuration instructions, in addition to a command set which enables you to manage the power supply from an external source. Error messages and calibration procedures are also included. This manual is designed for the user who is familiar with ba
Summary of the content on the page No. 10
About This Manual Appendix B SCPI Command Reference Describes the Standard Commands for Programmable Instruments (SCPI) commands supported by various products with the Multichannel Interface installed. Appendix C Error Messages Describes the error messages that could appear during operation. Appendix D Calibration Provides the calibration procedures and parameters. Manual Revisions The current release of this manual is listed below. Updates may be issued as an addendum. Release 2.1 (2003-04
Summary of the content on the page No. 11
Table of Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiii List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv Section 1. Features and Specifications Description . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 12
Power Supply Regulation Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Constant Voltage (CV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Constant Current (CC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Automatic Mode Crossover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Remote Control Modes . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 13
SHUTdown Sub-Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Protection SHUTdown Sub-Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Remote CONtrol Sub-Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Current SHare Sub-Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 QUEStionable Status Register. . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 14
Appendix B. SCPI Command Reference Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Codes and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 IEEE 488.2 Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 SCPI Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Summary of the content on the page No. 15
List of Tables Table 1.1 Specifications for HPD 300 W with GPIB-M or CANbus . . . . . . . . . . . 19 Table 1.2 Specifications for XFR 1200 W with GPIB-M or CANbus . . . . . . . . . . 20 Table 1.3 Specifications for XFR 2800 W with GPIB-M or CANbus . . . . . . . . . . 21 Table 1.4 Specifications for XHR 1000 W with GPIB-M or CANbus . . . . . . . . . . 22 Table 1.5 Specifications for XPD 500 W with GPIB-M or CANbus . . . . . . . . . . . 23 Table 1.6 Specifications for XT 60 W with GPIB-M or CANbus
Summary of the content on the page No. 16
List of Tables Table B.11 Protection Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Table B.12 User Lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Table B.13 Output State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Table B.14 Auto Sequence Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Table B.15 Expressions . . . . . . . . . . . . . .
Summary of the content on the page No. 17
List of Figures Figure 2.1 XFR and XHR Power Supply Front Panel with GPIB-M Interface. . . . 26 Figure 2.2 XPD Power Supply Front Panel with GPIB Interface. . . . . . . . . . . . . . 27 Figure 2.3 XT and HPD Power Supply Front Panel with GPIB Interface . . . . . . . 27 Figure 2.4 XFR 2800 Watt Power Supply Rear Panel with GPIB-M Interface . . . 28 Figure 2.5 XFR 1200 Watt Power Supply Rear Panel with GPIB-M Interface . . . 28 Figure 2.6 XHR Power Supply Rear Panel with GPIB-M Interface. . . . .
Summary of the content on the page No. 18
List of Figures xvi Operating Manual for Multichannel Functionality (GPIB-M)
Summary of the content on the page No. 19
Section 1. Features and Specifications Description The internal GPIB-M interface card allows you to operate your power supply from a computer controller via the IEEE-488 communications bus. The GPIB-M interface allows complete remote programming of your power supply, including status reporting, settings query, and service request generation with user-designated conditions. Both the voltage and current output are precisely programmed directly in volts and amps with 16-bit resolution. Additio
Summary of the content on the page No. 20
Features and Specifications Features and Functions Programmable Output voltage and current Functions Soft limits for voltage and current Overvoltage protection Output enable/disable Ten, 99-step auto sequences for easy programming of complex test routines Ten stored settings Five load protection mechanisms including fold protection in CV or CC mode Readback Actual measured voltage and current Functions Voltage and current settings Soft voltage and current limits Overvolta