Whistler 200/400 WATT user manual

User manual for the device Whistler 200/400 WATT

Device: Whistler 200/400 WATT
Category: Power Supply
Manufacturer: Whistler
Size: 0.72 MB
Added : 3/24/2014
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Whistler 200/400 WATT. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Whistler 200/400 WATT.

For your convenience

If looking through the Whistler 200/400 WATT user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Whistler 200/400 WATT on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Whistler 200/400 WATT to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Whistler 200/400 WATT User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Whistler 200/400 WATT but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Whistler 200/400 WATT. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OWNER’S MANUAL
200/400 WATT
POWER INVERTERS
THE WHISTLER GROUP, INC.
CORPORATE HEADQUARTERS
13016 N. Walton Blvd.
Bentonville, AR 72712
TEL (479) 273-6012 FX (479) 273-2927
www.whistlergroup.com
CUSTOMER RETURN CENTER
1201 N. Dixieland Rd.
Rogers, AR 72756
Consumer Relations Tel (800) 531-0004
Email: info@whistlergroup.com
P/N 205563
© 2006 The Whistler Group, Inc.

Summary of the content on the page No. 2

INTRODUCTION If you have questions concerning the operation of this Whistler product Dear Whistler Owner, please call customer service: For many of us, a vehicle is more than just transportation. It can be a mobile office, communications or entertainment center, or simply an expression of our personality. Whistler 1-800-531-0004 products are designed to make the time you spend in your Hours: vehicle more productive, more fulfilling, safer, or just simply more fun. Our mission is to provide produ

Summary of the content on the page No. 3

TABLE OF CONTENTS WHISTLER FEATURES A Word About WHISTLER Power Inverters. Topic Page Features Summary......................................................................3 WHISTLER inverters convert low voltage, direct current Important Information................................................................4 (DC) to 110 volt alternating household current (AC). The AC output is called “modified sine wave”. See “Technical Inverter Basics ................................................

Summary of the content on the page No. 4

IMPORTANT INFORMATION INVERTER BASICS Important Information About Your New WHISTLER Getting Started Power equipment and appliances which operate with motors Inverter. or tubes require an initial surge of power to get them up and running. This power surge is referred to as the "starting load" This manual will provide you with directions for the safe or "peak load." (By comparison, electrical devices such as and efficient operation of your WHISTLER inverter. Read standard light bulbs do not re

Summary of the content on the page No. 5

INVERTER BASICS INVERTER BASICS Don’t Push It. If a piece of equipment or an appliance will not operate, first confirm that the inverter has been properly connected to Although your WHISTLER inverter has the capacity to pro- the 12 volt power source (See "Making The Connection"). If vide power output (excess current) equal to approximately all connections have been properly made, turn the inverter two times its rated wattage capacity for a very brief period, rocker switch ON (l), OFF (O) and ON

Summary of the content on the page No. 6

OPERATION OPERATION 6. Remove the cigarette lighter and push the adapter plug Making the Connection. firmly into the cigarette lighter socket.* (Make certain This inverter is designed to connect to your 12 volt battery both the socket and adapter plugs are clean.) using the light socket plug or by the supplied battery cables (for appliances over 150 watts* 400 watt model). Note: Making The Connection. • If the equipment or appliance you intend to operate 1. Make certain that the inverter rocker

Summary of the content on the page No. 7

OPERATION OPERATION • The use of an extension cord from the inverter to the appli- • 400 watt model - If the supplied cables are too short ance or equipment being operated will not significantly to allow for placement of the inverter in a desired decrease the power being generated by the inverter. For location, the inverter may be connected to the power best operating results, the extension cord should be no source using a #8 wire, up to 12’ - #4 wire for longer more than 50 feet long. lengths.

Summary of the content on the page No. 8

ADDITIONAL FEATURES OPERATION within the appliance or equipment being operated. If the Automatic Shut Down & Related Safety Features. fuse(s) does blow, turn off and disconnect the appliance or Each inverter has an unique LED indicator warning light sys- equipment from the inverter immediately, repair the related tem which operates in conjunction with the automatic shut problem and replace the fuse(s). The internal fuses are down feature. These indicator lights operate as follows: replaceable

Summary of the content on the page No. 9

CARE AND MAINTENANCE ADDITIONAL FEATURES To maintain your inverter in proper working condition, note 2. Low Battery Voltage Alarm/Shutdown Protection a) When the input voltage from the 12 volt power source the following important safety precautions: drops below 10.5 volts, an audible tone will be heard. This is the low battery voltage alarm. • MOISTURE. Keep the inverter dry. Do not expose it b) The inverter will automatically shut down when the to moisture. Do not operate the inverter if you

Summary of the content on the page No. 10

OPERATING PRINCIPLES OPERATING PRINCIPLES For You Technical Types. majority of AC voltmeters are calibrated for RMS voltage and assume that the measured waveform will be a pure sine 1. Basic Operating Principles: wave. WHISTLER inverters work in two stages. During the first Consequently, these meters will not read the RMS modified stage, the DC to DC converter increases the DC input voltage sine wave voltage correctly and, when measuring your from the power source (e.g. a 12 volt battery) to 14

Summary of the content on the page No. 11

OPERATION SUMMARY OPERATION SUMMARY • Before attempting to use medical equipment see page 4. • This inverter is designed to be connected to the power source with the supplied cables or with #8 wire up to 12’ • Use only fuses which conform with the design specifica- - #4 wire for longer length. When utilizing the supplied tions outlined in this manual. cables do not attempt to modify or lengthen them. • When operating the inverter with the engine off, start the • When operating this inverter wit

Summary of the content on the page No. 12

TROUBLESHOOTING TROUBLESHOOTING PROBLEM: Low Battery Alarm On All The Time Please visit our Inverter FAQ page on our website Problem Solution w wh hiis st tlle er rg gr ro ou up p (www. .com), for more troubleshooting informa- Input voltage below Keep input voltage above 10.5 volts. 10.5 volts to maintain tion and FYI topics. regulation. PROBLEM: TV Interference Poor or weak battery Replace battery. Problem Solution condition. Inadequate power being Use lower gauge wire. Electrical interfere

Summary of the content on the page No. 13

TROUBLESHOOTING SPECIFICATIONS PROBLEM: TV Does Not Work WHISTLER 200 WATT INVERTER SPECIFICATIONS Maximum Continuous Power .....................200 Watts Problem Solution Maximum Surge Capability (Peak Power) 400 Watts* * TV does not turn on Try rocking the ON/OFF No Load Current Draw......................................<0.3 A switch of the inverter while Waveform ....................................Modified Sine Wave leaving the TV ON Operating Input Voltage Range .......11– 15 Volts DC (

Summary of the content on the page No. 14

WARRANTY WARRANTY Consumer Warranty IMPORTANT: Whistler will not assume responsibility for loss This Whistler is warrantied to the original purchaser for a or damage incurred in shipping. Therefore, please ship your period of two years, from the date of original purchase, unit insured with return receipt requested. against all defects in materials and workmanship. This limited warranty is void if the unit is abused, modified, 2. Include with your unit the following information, clearly printed:

Summary of the content on the page No. 15

WARRANTY Service Out Of Warranty Units will be repaired at “out of warranty” service rates when: • The unit’s original warranty has expired. • Dated store receipt is not supplied. • The unit has been returned without its serial number. • The unit has been abused, modified, installed improperly, or had its housing removed. The minimum out of warranty service fee for your Whistler 200 watt inverter is $15.00 (U.S.) and the 400 watt inverter is $25.00 (U.S.). If you require out of warranty service


Alternative user manuals
# User manual Category Download
1 Whistler 1200 WATT User manual Power Supply 4
2 Whistler 1200 User manual Power Supply 1
3 Whistler 2000 WATT User manual Power Supply 0
4 Whistler 800 WATT POWER INVERTER User manual Power Supply 12
5 Whistler 3000 WATT User manual Power Supply 1
6 Whistler PP350AC User manual Power Supply 2
7 Whistler 3000 User manual Power Supply 1
8 Whistler Power Inverter User manual Power Supply 5
9 Whistler PRO-1600W User manual Power Supply 1
10 Whistler PRO-2000W User manual Power Supply 0
11 Whistler PRO-1200W User manual Power Supply 0
12 Whistler 2000 User manual Power Supply 0
13 Whistler PRO-3000W User manual Power Supply 0
14 Whistler PRO-2500W User manual Power Supply 0
15 Whistler PP150AC User manual Power Supply 0
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2