Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG user manual

User manual for the device Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG

Device: Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG
Category: Power Supply
Manufacturer: Tripp Lite
Size: 0.54 MB
Added : 2/4/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG.

For your convenience

If looking through the Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Tripp Lite SmartPro & OmniSmart AGOM350KSR57HG. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual

®
SmartPro & OmniSmart

UPS Systems with
UL1778
UL1778 2601-1
OmniSmart
Hospital-Grade Plugs &
Medical Grade UPS Systems
Receptacles
 Full Isolation (Less than 300µA Leakage)
 Hospital-Grade Plug & Receptacles
 Hospital-Grade Plug & Receptacles
 Line-Interactive Operation
 Line-Interactive Operation
 120V Input
 120V Input
 450 - 1400VA Output Capacities
 330 - 1000VA Output Capacities
Important Safety Instructions
2
Quick Installation
3
Basic Operation
5
Storage & Se

Summary of the content on the page No. 2

Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty. UPS Location Warnings • Your UPS incorporates fusing only in the ungrounded phase conductor. UL2601-1 certified UPS systems (see Specifications) must not be used in countries other than the United States and Canada and must be used only in

Summary of the content on the page No. 3

Quick Installation Note! Although some installation procedures are common to all models, some procedures vary depending on whether you are installing a SmartPro model or an OmniSmart model. 1 For All Models—Plug your UPS into a 3-wire grounded, 120V AC, 60 Hz utility outlet. Note: UL2601-1 listed UPS systems only meet UL standard 2601-1 for medical equipment when plugged into a hospital-grade outlet. For SmartPro Models Only: After you plug the UPS into a live AC outlet, the UPS will automatical

Summary of the content on the page No. 4

Quick Installation optional These connections are optional. Your UPS will function properly without these connections. 1 Serial Communications (Select models only) Using the cable provided, connect the DB9 port of your computer to the DB9 port of your UPS. Download the PowerAlert UPS monitoring software program appropriate for your operating system from www.tripplite.com and install it on your computer. 1 2 USB Communications (Select Models Only) Using the cable provided, connect the USB port of

Summary of the content on the page No. 5

Basic Operation Note! Although some operational features and functions are common to all models, some operational features vary depending on whether you are operating a SmartPro model or an OmniSmart model. Buttons For SmartPro Models Only—“POWER” Button: • To turn the UPS ON: with the UPS plugged into a live AC wall outlet,* press and hold the POWER button for about two seconds.** Release the button. If utility power is absent, you can “cold-start” the UPS (i.e.: turn it ON and supply power for

Summary of the content on the page No. 6

Basic Operation continued For All Models—“MUTE/TEST” Button: To Silence (or “Mute”) UPS Alarms: briefly press and release the MUTE/TEST button.* To Run a Self-Test: with your UPS plugged in and turned ON, press and hold the MUTE/TEST button for two seconds.* Continue holding the button until the alarm beeps several times and the UPS performs a self test. See “Results of a Self-Test” below. Note: you can leave connected equipment on during a self-test. Your UPS, however, will not perform a self-t

Summary of the content on the page No. 7

Basic Operation continued Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on. “POWER” LED For SmartPro Models Only: this green LED lights continuously when the UPS is ON and supplying connected equipment with AC power from a utility source. The LED flashes and an alarm sounds (4 short beeps followed by a pause) to indicate the UPS is operating from its internal batteries during a blackout or severe brownout. If the blackout or severe b

Summary of the content on the page No. 8

Basic Operation continued “BATTERY CHARGE / BATTERY POWER” LED: For SmartPro Models Only: when the UPS is operating from utility power, this LED indicates the approximate charge state of the UPS’s internal batteries: red indicates the batteries are beginning to charge; yellow indicates the batteries are roughly midway through charging; and green indicates the batteries are fully charged. When the UPS is operating from battery power during a blackout or severe brownout, this LED indicates the app

Summary of the content on the page No. 9

Basic Operation continued Other UPS Features Hospital Grade AC Receptacles: The receptacles provide your con- nected equipment with AC line power during normal operation and battery power during blackouts and brownouts. They also protect your equipment against damaging surges and line noise. Tel/DSL Protection Jacks (Select Models Only): These jacks protect connected equipment against surges travelling over the modem/fax or telephone line. Connecting your equipment to these jacks is optional. Yo

Summary of the content on the page No. 10

Basic Operation continued Power Sensitivity Adjustment (Select Models Only): This dial is normally set fully counterclockwise, which enables the UPS to pro- tect against waveform distortions in its AC input. When such distor- NORM DELAY tion occurs, the UPS will normally switch to providing PWM sine wave power from its battery reserves for as long as the distortion is present. In areas with poor utility power or where the UPS’s input power comes from a backup generator, chronic waveform distort

Summary of the content on the page No. 11

Storage & Service continued Service Before returning your UPS for service, follow these steps: 1. Review the installation and operation instructions in this manual to ensure that the service problem does not originate from a misreading of the instructions. Also, check that the UPS System’s circuit breaker(s) are not tripped. This is the most common cause of service inquiries which can be easily remedied by following the resetting instructions in this manu- al. 2. If the problem continues, do not

Summary of the content on the page No. 12

Specifications Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. ® ™ SmartPro & OmniSmart Medical-Grade UPS Systems Model: OMNISMART350HG SMART700HG SMART1200XLHG Series: AGOM350KSR57HG AGSM700PSR3HG AGSM1200PSR3HG Output Capacity (VA/Watts): 330/225 700/450 1000/750 Battery Runtime (Half Load/Full Load) Minutes: 46/18 42/18 34/16+ Battery Recharge Time: 2-4 hrs. 2-4 hrs. 2-4 hrs. Approvals: UL2601-1, UL1778 UL2601-1, UL1778 UL2601-1, UL1778

Summary of the content on the page No. 13

Manual de operación ™ ® SmartPro y OmniSmart ™ Sistemas UPS con 2601-1 UL1778 UL1778 OmniSmart enchufes y receptáculos Sistemas UPS grado médico grado hospital  Menos de 300µA de fuga  Enchufe y receptáculos grado hospital  Enchufe y receptáculos grado hospital  Operación interactiva con la línea  Operación interactiva con la línea  Entrada de 120 V  Entrada de 120 V  Capacidades de salida de 450 - 1400 VA  Capacidades de salida de 330 - 1000 VA Importantes instrucciones de seguridad

Summary of the content on the page No. 14

Importantes instrucciones de seguridad GUARDE ESTAS INSTRUCCIONES Este manual contiene advertencias e instrucciones importantes que deben seguirse durate la instalación, operación y almacenamiento de todos los sistemas UPS de Tripp Lite. De no cumplirse estas advertencias, la garantía será anulada. Advertencias sobre la colocación del UPS • Su sistema UPS contiene fusibles sólo en el conductor de fase sin conexión a tierra. Los sistemas UPS certificados por UL2601-1 (véase Especificaciones) no s

Summary of the content on the page No. 15

Instalación rápida ¡Nota! Aunque algunos procedimientos de instalación son comunes para todos los modelos, otros pueden variar dependiendo de si instala un modelo SmartPro o un OmniSmart. 1 Para todos los modelos—Enchufe su sistema UPS a una toma de corriente de 120 V CA, 60 Hz. Los sistemas UPS sólo cumplen la norma UL 2601-1 para equipo médico si se conectan a una toma de grado hospitalario. Sólo para modelos SmartPro: Después de conectar el UPS en una toma de corriente alterna con energía, el

Summary of the content on the page No. 16

Instalación rápida optativa Estas conexiones son optativas. Este sistema UPS funcionará correctamente sin estas conexiones. 1 Comunicaciones en serie (sólo para ciertos modelos) Utilizando el cable incluido, conecte el puerto DB9 de la computadora al puerto DB9 del UPS. Descargue la versión del programa PowerAlert de control del UPS apropiada para su sistema operativo en la dirección de Internet www.tripplite.com, e instálelo en la computadora. 2 Comunicaciones USB (sólo para ciertos modelos) 1

Summary of the content on the page No. 17

Operación básica ¡Nota! Aunque algunas características y funciones de operación son comunes a todos los modelos, otras varían dependiendo de si opera un modelo SmartPro o un OmniSmart. Sólo para modelos SmartPro— Botones Botón “POWER” (Alimentación): • Para encender el UPS: Con el UPS conectado en una toma de CA con energía*, presione y mantenga presionado el botón POWER (Alimentación) por cerca de dos segundos.** Suelte el botón. Si no hay energía de la red, puede “arrancar en frío” el UPS (es

Summary of the content on the page No. 18

Operación básica continuación Para todos los modelos—Botón “MUTE/TEST” (Silencio/Prueba): Para silenciar las alarmas UPS: Presione brevemente el botón MUTE/TEST (Silencio/Prueba) y luego suéltelo.* Para ejecutar una auto-prueba: Con su UPS conectado y encendido, presione y mantenga presionado el botón MUTE/TEST (Silencio/Prueba) por dos segundos.* Siga presionando el botón hasta que la alarma suene varias veces y el UPS realice una auto-prueba. Vea “Resultados de una auto-prueba” más adelante. N

Summary of the content on the page No. 19

Operación básica continuación Luces indicadoras Todas las descripciones de luces indicadoras aplican cuando el sistema UPS está encendido y conectado a una toma de CA. LED “POWER” (Alimentación): Sólo para modelos SmartPro: Este LED verde se enciende permanentemente cuando el UPS está encendido y proporcionando energía de CA al equipo conectado desde el suministro de red. El LED destella y una alarma suena (4 pitidos cortos seguidos de una pausa) para indicar que el UPS está operando con sus bat

Summary of the content on the page No. 20

Operación básica continuación LED “BATTERY CHARGE / BATTERY POWER” (Carga de batería/Energía de batería): Sólo para modelos SmartPro: Cuando el UPS opera con la energía de la red, este LED indica el estado aproximado de carga de las baterías internas del UPS; el rojo indica que las baterías están comenzando a cargarse; el amarillo indica que las baterías están aproximadamente a media recarga; y el verde indica que las baterías están totalmente cargadas. Cuando el UPS opera con energía de las bat


Alternative user manuals
# User manual Category Download
1 Tripp Lite 120 User manual Power Supply 9
2 Tripp Lite 120V User manual Power Supply 26
3 Tripp Lite 1500RMXL2UA User manual Power Supply 15
4 Tripp Lite 120V Input, Line-Interactive UPS System SMART750USB User manual Power Supply 20
5 Tripp Lite 200305107 User manual Power Supply 0
6 Tripp Lite 1400VA User manual Power Supply 7
7 Tripp Lite 1500SLT User manual Power Supply 8
8 Tripp Lite 200204171 93-2036_EN User manual Power Supply 1
9 Tripp Lite 200904140 User manual Power Supply 1
10 Tripp Lite 200803016 95-2924 User manual Power Supply 1
11 Tripp Lite 2009XXXXX 93-1350_EN User manual Power Supply 1
12 Tripp Lite 220 User manual Power Supply 5
13 Tripp Lite 20KVA User manual Power Supply 10
14 Tripp Lite 2-Port In-Line PS/2 KVM Switch with Audio B032-002-R User manual Power Supply 11
15 Tripp Lite 240 User manual Power Supply 2
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2