Toshiba VF-FS1 user manual

User manual for the device Toshiba VF-FS1

Device: Toshiba VF-FS1
Category: Power Supply
Manufacturer: Toshiba
Size: 4.86 MB
Added : 10/6/2013
Number of pages: 252
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Toshiba VF-FS1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Toshiba VF-FS1.

For your convenience

If looking through the Toshiba VF-FS1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Toshiba VF-FS1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Toshiba VF-FS1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Toshiba VF-FS1 User manual - Online PDF
Advertisement
« Page 1 of 252 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Toshiba VF-FS1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Toshiba VF-FS1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Industrial Inverter Instruction Manual
TOSVERT VF -FS1
E6581381
Safety
precautions I
Introduction
II II
Contents
Industrial Inverter
Read first
1
For 3-phase induction motors
Connection
2
Operations
3
Instruction Manual
Basic VF -FS1
4
operations
Basic
parameters 5
TM
TOSVERT VF-FS1
Extended
parameters 6
Applied
7
operation
TOSHIBA I NTERNATIONAL TOSHIBA I NTERNATIONAL CORPORATION PTY.,
Monitoring the
CORPORATION LTD
8
operation status
13131 West Little York RD., Houston, 2 Morton Stre

Summary of the content on the page No. 2

Summary of the content on the page No. 3

E6581381 I I. Safety precautions The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely, prevent injury to yourself and other people around you as well as to prevent damage to property in the area. Thoroughly familiarize yourself with the symbols and indications shown below and then continue to read the manual. Make sure that you observe all warnings given. Explanation of markings Marking Meaning of marking Indicates that e

Summary of the content on the page No. 4

E6581381 ■ General Operation I See item Danger • Never disassemble, modify or repair. 2. This can result in electric shock, fire and injury. For repairs, call your sales distributor. Disassembly prohibited 2.1 • Never remove the front cover when power is on or open door if enclosed in a cabinet. The unit contains many high voltage parts and contact with them will result in electric shock. 2. • Don't stick your fingers into openings such as cable wiring hole and cooling fan covers. This can

Summary of the content on the page No. 5

E6581381 ■ Transportation & installation I See item Danger • Do not install or operate the inverter if it is damaged or any component is missing. 1.4.4 This can result in electric shock or fire. Please consult your local sales agency for repairs. Call your local sales agency for repairs. 1.4.4 • Do not place any inflammable objects nearby. Prohibited If a flame is emitted due to malfunction, it may result in a fire. • Do not install in any location where the inverter could come into contact

Summary of the content on the page No. 6

E6581381 Danger See item I 2.1 • Electrical installation work must be done by a qualified expert. Connection of input power by someone who does not have that expert knowledge may result in fire or electric shock. • Connect output terminals (motor side) correctly. 2.1 If the phase sequence is incorrect, the motor will operate in reverse and that may result in injury. • Wiring must be done after installation. 2.1 If wiring is done prior to installation that may result in injury or electric sh

Summary of the content on the page No. 7

E6581381 See item I Warning • Observe all permissible operating ranges of motors and mechanical equipment. (Refer to 3. the motor's instruction manual.) Not observing these ranges may result in injury. Prohibited When sequence for restart after a momentary failure is selected (inverter) See item Warning • Stand clear of motors and mechanical equipment. 6.12.1 If the motor stops due to a momentary power failure, the equipment will start suddenly after power recovers. This could result i

Summary of the content on the page No. 8

E6581381 Disposal I See item Warning • If you throw away the inverter, have it done by a specialist in industry waste disposal(*). 16. If you throw away the inverter by yourself, this can result in explosion of capacitor or produce noxious gases, resulting in injury. (*) Persons who specialize in the processing of waste and known as "industrial waste product collectors and transporters" or "industrial waste disposal persons. "If the Mandatory collection, transport and disposal of industrial

Summary of the content on the page No. 9

E6581381 II. Introduction II Thank you for your purchase of the Toshiba "TOSVERT VF-FS1” industrial inverter. This is the Ver.100 / Ver.101 CPU version inverter. Please be informed that CPU version will be frequently upgraded. ■ Features 1. Built-in noise filter 1) All models in both the 200V and 400V series have a noise filter inside. 2) Can be compliant with European CE marking standard 3) Reduces space requirements and cuts down on time and labor needed in wiring. 2. Simple operation 1) Autom

Summary of the content on the page No. 10

E6581381  Contents  I Safety precautions .........................................................................................................................................................1 II Introduction ....................................................................................................................................................................7 1. Read first.........................................................................................................

Summary of the content on the page No. 11

E6581381 6.3 Terminal function selection ................................................................................................................................F-5 6.4 Basic parameters 2............................................................................................................................................F-13 6.5 Frequency priority selection...............................................................................................................................F

Summary of the content on the page No. 12

E6581381 12. Specifications................................................................................................................................................................L-1 12.1 Models and their standard specifications ...........................................................................................................L-1 12.2 Outside dimensions and mass ......................................................................................................................

Summary of the content on the page No. 13

E6581381 1. Read first 1.1 Check product purchase Before using the product you have purchased, check to make sure that it is exactly what you ordered. Warning 1 Use an inverter that conforms to the specifications of power supply and three-phase induction motor being used. If the inverter being used does not conform to those specifications, not only will the three-phase induction motor not rotate correctly, it may also cause serious accidents through Mandatory overheating and fire. Inv

Summary of the content on the page No. 14

E6581381 1.2 Contents of the product Explanation of the name plate label. Type Form - - -A 2 2 VF FS 1 4 007 P L E WN 1 Applicable motor Default interface Special specification code Model name Input (AC) voltage Additional functions I capacity logic* None: No filter inside 004 : 0.4kW TOSVERT 2 : 200V to 240V WN : Negative M: Built-in basic filter A : is the number 007 : 0.75kW VF-FS1series 4 : 380V to 480V WP : Positive L: Built-in 015 : 1.5kW EMI class A filter 022 : 2.2kW D: Built-in 0

Summary of the content on the page No. 15

E6581381 1.3 Names and functions 1.3.1 Outside view 1 [Operation panel] A-3

Summary of the content on the page No. 16

E6581381 Unlock position mark The front panel is unlocked when the dot on the locking screw is on Charge lamp this (upper) side. Indicates that high voltage is still present within the inverter. Do not Front panel locking screw open the terminal board cover The inverter came with this while this is lit. screw in the locked position. 1 So from this position, turn the screw 90° counterclockwise to unlock the front panel, or turn it 90° clockwise to lock the front panel. Front panel The screw does

Summary of the content on the page No. 17

E6581381 Example of the label 1 1.3.2 Power circuit and control circuit terminal boards In case of the lug connector, cover the lug connector with insulated tube, or use the insulated lug connector. 1) Power circuit terminal board In case of the lug connector, cover the lug connector with insulated tube, or use the insulated lug connector. Screw size tightening torque M4 screw 1.3Nm 10.7lb in M5 screw 2.5Nm 22.3lb in M6 screw 4.5Nm 40.1lb in M8 screw 12Nm 106lb in M12 screw 41Nm 360lb

Summary of the content on the page No. 18

E6581381 VFFS1-2004 ∼ 2037PM 1 VFFS1-4004 ∼ 4055PL Note: EMC plate is supplied as standard. A-6

Summary of the content on the page No. 19

E6581381 VFFS1-2055, 2075PM -4075, 4110PL 1 VFFS1-2110 ∼ 2185PM -4150 ∼ 4185PL Note: EMC plate is supplied as standard. A-7

Summary of the content on the page No. 20

E6581381 VFFS1-2220PM -4220, 4300PL 1 VFFS1-2300PM Each main circuit terminal has the structure shown in the figure below. Connect a cable to part A if it has a ring terminal, or to part B if it has no terminal (bare wire). Parts A and B accommodate different sizes of cables, so consult the cable size list for the size of cable connectable to each part. Note: EMC plate is supplied as standard. A-8


Alternative user manuals
# User manual Category Download
1 Toshiba 1500 User manual Power Supply 1
2 Toshiba 1600 User manual Power Supply 3
3 Toshiba 1600 Series User manual Power Supply 9
4 Toshiba 1500 SERIES User manual Power Supply 3
5 Toshiba 1000 Series User manual Power Supply 8
6 Toshiba 1500 Plus User manual Power Supply 1
7 Toshiba 15-80KVA User manual Power Supply 1
8 Toshiba 1600 XP UPS User manual Power Supply 82
9 Toshiba 1600EP Series User manual Power Supply 57
10 Toshiba 1800 User manual Power Supply 1
11 Toshiba 1700 Series User manual Power Supply 3
12 Toshiba 1800 SERIES User manual Power Supply 1
13 Toshiba 208 User manual Power Supply 1
14 Toshiba 4200FA CT/XT User manual Power Supply 5
15 Toshiba 4200FA XT User manual Power Supply 2
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2