Texas Memory Systems RAM-SAN 520 user manual

User manual for the device Texas Memory Systems RAM-SAN 520

Device: Texas Memory Systems RAM-SAN 520
Category: Power Supply
Manufacturer: Texas Memory Systems
Size: 0.82 MB
Added : 5/28/2013
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Texas Memory Systems RAM-SAN 520. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Texas Memory Systems RAM-SAN 520.

For your convenience

If looking through the Texas Memory Systems RAM-SAN 520 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Texas Memory Systems RAM-SAN 520 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Texas Memory Systems RAM-SAN 520 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Texas Memory Systems RAM-SAN 520 User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Texas Memory Systems RAM-SAN 520 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Texas Memory Systems RAM-SAN 520. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




TM
RAM-SAN

User’s Guide







Any trademarks or registered trademarks used in this document belong to the companies that own them.

Copyright © 2003, Texas Memory Systems, Inc. All rights are reserved. No part of this work may be reproduced or used in
any form or by any means - graphic, electronic or mechanical, including photocopying, recording, taping, or information
storage and retrieval systems - without permission of the copyright owner.

Summary of the content on the page No. 2

Table of Contents Chapter 1 - Overview .............................................................................................................................................................1-1 Chapter 2 - Installation ..........................................................................................................................................................2-1 2.1 Inspection .............................................................................................

Summary of the content on the page No. 3

6.9 How to Contact Us .........................................................................................................................................................6-8 Chapter 7 – Specifications......................................................................................................................................................7-9 7.1 Physical Characteristics...........................................................................................................

Summary of the content on the page No. 4

Chapter 1 - Overview TM The RAM-SAN is a high-performance, multi-ported, solid-state disk. Memory capacity ranges from 16 gigabytes (GB) 1 through 128 GB in 16 GB increments . Memory is organized internally in 128-bit wide words and accessed via four parallel memory buses that can each sustain an aggregate bandwidth of up to 800 megabytes per second, giving a system bandwidth of up to 3.2 GB per second. The RAM-SAN features up to fifteen Fibre Channel I/O ports, each of which ca

Summary of the content on the page No. 5

Chapter 2 - Installation The RAM-SAN is shipped with memory boards and interfaces already installed. Before connecting to a power supply, please perform a preliminary inspection to check for any signs of loose parts, to ensure that all interfaces are still firmly positioned in place, and to check for any obvious signs of damage. During power-up it is recommended that a terminal be attached to the management port to observe its progress through the sequence of initial power-up tests.

Summary of the content on the page No. 6

The management port supports Ethernet connections via Telnet. The IP address may be assigned automatically using a DHCP, BOOTP or RARP server. The IP address may also be statically set using the ‘ipconfig’ command from the serial port. The serial connection on the management port may optionally be used to communicate with the RAM-SAN. The cable provided with the RAM-SAN connects to another serial port using the following settings: 8 data bits No parity 1 stop bit 9

Summary of the content on the page No. 7

Chapter 3 - Understanding Your RAM-SAN 3.1 Interface Slot Numbering Each device in a RAM-SAN has a unique internal address based on the physical location of the device in the system. An interface’s port number can be determined by inspecting the back of the RAM-SAN (see Figure 1). 3.2 Inside the RAM-SAN You can open the top of the RAM-SAN by removing the screws on the lid of the system. Standing at the back of the RAM- SAN and looking down into the system the interfaces are close

Summary of the content on the page No. 8

WARNING: Please exercise caution as you hot-swap power supplies for the RAM-SAN. Failure to follow these directions could result in injury or death. If you have any questions about this procedure, call Texas Memory Systems at 713-266-3200. 1. Turn off the power module that you plan to remove. Do not remove a hot swap power module from the chassis without turning the power module off. The master power switch can remain “ON” as can the other power modules. 2. Wait 45 seconds and rem

Summary of the content on the page No. 9

Figure 3 – Top-down View of RAM-SAN Internals The Front Panel Display Mounted on the front of the RAM-SAN is a front panel display (see Figure 4). When the RAM-SAN is in operation, the display reflects the system memory activity. The display monitors three things: location of memory accesses, bus bandwidth and which interface slots contain devices. RAM-SAN User’s Guide Texas Memory Systems, Inc. (February 7, 2003) 3-3

Summary of the content on the page No. 10

Figure 4 – RAM-SAN Front Panel The RAM-SAN display consists of four rows of lights. Each row corresponds to one of the four RAM-SAN system busses. The top row corresponds to interface ports 0, 1, 2 and 3, the next row to ports 4, 5, 6 and 7, the next row to ports 8, 9, 10 and 11, and the bottom row corresponds to interface ports 12, 13, 14, and 15. When any device on a bus is active, a light turns on in the ADDRESSES section of the display corresponding to which gigabyte of memory i

Summary of the content on the page No. 11

RAM-SAN User’s Guide Texas Memory Systems, Inc. (February 7, 2003) 3-1

Summary of the content on the page No. 12

Chapter 4 – Configuring the RAM-SAN This chapter focuses on configuring the RAM-SAN. This includes configuring the Ethernet parameters, resizing LUNS, and performing LUN Masking. 4.1 The RAM-SAN Monitor The RAM-SAN is managed through an interactive command tool. The management software is accessed over Ethernet or the serial port on the RAM-SAN. See section 2.4 for more information on connecting the hardware. 4.2 Configuring the Ethernet Port The Ethernet port may be configur

Summary of the content on the page No. 13

The amount of storage allocated to each Fibre Channel port may be changed using a simple configuration utility provided in the monitor. To enter this utility, type ‘partition’ on the monitor command line. You should see a message similar to this one: ram-san> ram-san> partition ** RAM-SAN partitioning utility ** Total memory size: 8192 Mb Command (h for help): To see a list of the available commands, type ‘h’ at the prompt. Command (h for help): h a add wwn to LUN

Summary of the content on the page No. 14

8 Gigabytes System 3 Gigabyte drive 3 Gigabyte drive 2 Gigabyte RAM-SAN Memory drive 1 2 3 & 4 Fibre Channel ports FC21 FC21 HBA 1 HBA 2 HBA 3 HBA 4 4.3.2 Resizing LUNs The first step in changing the configuration is to resize the LUNs. Since our new configuration calls for three different LUNs, we need to use the ‘r’ command to resize LUNs. This command allows us to keep or delete the previous LUN mask and port assign

Summary of the content on the page No. 15

Enter the LUN number: 1 Enter the Fibre Channel port: 5 Command (h for help): l Enter the LUN number: 2 Enter the Fibre Channel port: 5 Command (h for help): l Enter the LUN number: 3 Enter the Fibre Channel port: 9 Command (h for help): p Enter the LUN number (1-3, default is all): LUN 1 -- 3072 Mb ports: 5 access: Open access LUN 2 -- 3072 Mb ports: 5 access: Open access LUN 3 -- 2048 Mb ports: 9 access: Open access Command (h for help):

Summary of the content on the page No. 16

4.3.5 Saving the Configuration to Flash RAM The RAM-SAN has now been configured to allow access from four different HBAs to 3 different LUNs within the memory system. To actually commit the change we have made, we can use the ‘w’ command to save the configuration into Flash RAM. You may also use the ‘q’ command to quit the partitioning utility without saving any changes. RAM-SAN User’s Guide Texas Memory Systems, Inc. (February 7, 2003) 4-5

Summary of the content on the page No. 17

Chapter 5 – Using the Management Port The management port on the RAM-SAN allows an administrator to configure the system, monitor performance, and diagnose problems with the system. The ‘help’ command displays a list of commands available. The following sections provide a more detailed description of the commands available through the monitor. 5.1 testmem The ‘testmem’ command is used to verify the integrity of the system memory. This command causes the management port to generate

Summary of the content on the page No. 18

5.5 history The monitor maintains a volatile command history of the last 25 commands that have been entered. Using the ‘history’ command provides a listing of the history. Commands may be entered using the ‘<’ and ‘>’ keys to scroll through this history or the unix-like ‘!’ commands. The command history is volatile and will not be maintained between power cycles. 5.6 ipconfig The ‘ipconfig’ command allows for static IP configuration of the RAM-SAN. More information on this command m

Summary of the content on the page No. 19

5.13 status [port] The status command provides an overview of the RAM-SAN including Ethernet information, memory size, and the state of the Fibre Channel ports. The following output shows a sample status screen: ram-san> status Texas Memory Systems, Inc. RAM-SAN Monitor version 1.00 Ethernet address: 00:20:c2:00:07:f1 Ethernet IP: 192.94.231.201 Total memory size: 8192 MB - Ready port 1: --- port 2: offline port 3: --- port 4: --- port 5: 10:05:00:20:c2:00

Summary of the content on the page No. 20

Chapter 6 - Troubleshooting This chapter is a quick troubleshooting guide for the most common RAM-SAN errors. To verify basic RAM-SAN operation, please consult Chapter 5 for instructions on running the system diagnostics. Below is a short list of RAM-SAN errors, symptoms and solutions. If this guide does not identify and correct your problem, please call Texas Memory Systems customer support at (713) 266-3200. 6.1 Basic Items to Check When touching any of the internal components


Alternative user manuals
# User manual Category Download
1 Texas Memory Systems RamSan- 300 User manual Power Supply 0
2 Texas Memory Systems 320 User manual Power Supply 0
3 Texas Memory Systems RamSan-500 User manual Power Supply 0
4 Texas Memory Systems RamSan-300/320 User manual Power Supply 0
5 Texas Memory Systems 325 User manual Power Supply 0
6 Sony AC U50A User manual Power Supply 5
7 Sony AC LS1 User manual Power Supply 2
8 Sony NP-FM30 User manual Power Supply 35
9 Sony NP FX101 User manual Power Supply 1
10 Sony NH-AAA-DA User manual Power Supply 2
11 3Com 3645A User manual Power Supply 0
12 3Com 3CNJPSE24 User manual Power Supply 2
13 3Com COREBUILDER 5000 User manual Power Supply 0
14 3Com 3646A User manual Power Supply 0
15 3Com External PoE Power System PSE2500-A3 User manual Power Supply 1