Siemens Stober CombiDrive CM400/3 user manual

User manual for the device Siemens Stober CombiDrive CM400/3

Device: Siemens Stober CombiDrive CM400/3
Category: Power Supply
Manufacturer: Siemens
Size: 0.93 MB
Added : 9/23/2014
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens Stober CombiDrive CM400/3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens Stober CombiDrive CM400/3.

For your convenience

If looking through the Siemens Stober CombiDrive CM400/3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens Stober CombiDrive CM400/3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens Stober CombiDrive CM400/3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens Stober CombiDrive CM400/3 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens Stober CombiDrive CM400/3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens Stober CombiDrive CM400/3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
STÖBER CombiDrive
SIEMENS Micromaster integrated
Installation and Commissiong instructions
It ist essential to read and comply with these
instructions prior to installation and commissioning!
01/2001

Summary of the content on the page No. 2

Contents Safety precautions................................................................................................ ..1 1. OVERVIEW ..................................................................................................... ..2 2. INSTALLATION............................................................................................... ..3 3.OPERATING INFORMATION ........................................................................... 10 4. CLEAR TEXT DISPLAY MODULE & SY

Summary of the content on the page No. 3

Safety Precautions Before installing and putting this equipment into operation, please read these safety precautions and warnings carefully and all the warning signs attached to the equipment. Make sure that the warning signs are kept in a legible condition and replace missing or damaged signs. WARNING CAUTION This equipment contains hazardous voltages and • Children and the general public must be controls hazardous rotating mechanical parts. Loss prevented from accessing or approaching the of l

Summary of the content on the page No. 4

English 2. Installation 1. OVERVIEW ® The CombiDrive is an integrated motor/inverter for variable speed applications. The inverter is microprocessor-controlled and uses state of the art IGBT technology for reliability and flexibility. A special pulse-width modulation method with ultrasonic pulse frequency permits extremely quiet motor operation. Inverter and motor protection is provided by comprehensive protective functions. Features: • Easy to install and commission. • Closed loop control usi

Summary of the content on the page No. 5

2. Installation English 2. INSTALLATION WARNING To guarantee the safe operation of the equipment it must be installed and commissioned by qualified personnel only. Take particular note of the general and regional installation and safety regulations regarding work on high voltage installations (e.g. VDE), as well as the relevant regulations regarding the correct use of tools and personal protective gear. Use the lifting eyes provided if the motor has to be lifted. Do not lift machine sets (e.g.

Summary of the content on the page No. 6

English 2. Installation 2.2 Mechanical Installation ® Figures 1 and 2 show dimensional information for all CombiDrive variants. Note: ‘Case size’ refers to the type of inverter box mounted on the motor. ‘Motor frame’ refers to the motor frame size only. ® Remove or tighten down screw-in lifting eyes prior to using the CombiDrive . Stable foundations or mounting conditions, exact alignment of the motors and a well-balanced transmission element are essential for quiet, vibration-free running. If

Summary of the content on the page No. 7

2. Installation English ® CombiDrive – Dimension (Only dimensions of the motor, total dimensions of the gear motor see MGS-catalog, Impr.-No. 440 637) qx = Max. dimension; Given either through the inverter or through the fan cowl. Motor Dimension Motor-type Inverter type Width (b) qx output rating w´ 71 K 0,25 kW PM 25/1 122 182 237 71 L 0,37 kW PM 37/1 122 182 237 80 K 0,55 kW PM 55/1 122 193 259,5 80 L 0,75 kW PM 75/1 122 193 259,5 Motor Dimension Motor-type Inverter type Width (b) qx output

Summary of the content on the page No. 8

English 2. Installation 2.3 Electrical Installation Remove the four M5 cross-head screws on the inverter's cover to access the electrical terminals (see Figure 3 and Figure 4). Notes: (1) Refer to the electrical data table for cable sizes (see section 6). (2) We recommend introducing a `drip loop' when connecting the mains and control cables (see Figure 5). CAUTION The printed circuit boards contain CMOS components that are particularly sensitive to static electricity. For this reason, avoid t

Summary of the content on the page No. 9

2. Installation English 2.3.1 Mains Cable Connections Ensure that the power source supplies the correct voltage and is designed for the necessary current. Ensure that the appropriate circuit-breakers with the specified current rating are connected between the power supply ® and CombiDrive (see section 6). o Use Class 1 60/75 C copper wire only. Use a 4-core screened cable (for cross-section of each core see section 6). If crimp terminals are used then they must be insulated. If crimps are not

Summary of the content on the page No. 10

English 2. Installation 3 1.8 mm max. 1 2 OR 1 3 2 Figure 4b: Connecting Control Wires to PL800 Figure 2: Cable Connections with Drip Loop © STÖBER plc 1998 05.02.01 8

Summary of the content on the page No. 11

2. Installation English 2.3.3 Block Diagram PE 3 AC 380 - 500 V SI L1, L2, L3 PL800 PE +10V (10 mA max.) 1 0V V: 0 - 10 V 2 OR 2 - 10 V AIN+ 3 A/D AIN- 4 I: 0 - 20 mA 4 - 20 mA ~ GR - 24 V + DIN1 5 DIN2 6 DIN3 7 Power supply for OR PI feedback +15V transducer or 8 other load CPU OR PI -ve Input 9 A/D PI +ve Input 10 ZK Relay RL1B 11 Connections RL1C 12 WR SK200 3 ~ 1 5V Connections for 2 0V RS485 Serial Link or OPm2 PE PE 3 N (-) U, V, W I V 4 P (+) PI Input Type JP302 JP303 M 3 ~ Analogue Inp

Summary of the content on the page No. 12

English 3. Operating Information 3. OPERATING INFORMATION WARNING The equipment must not be switched on until after its cover has been fitted and the cover screws have been tightened to the correct torque. After the power has been turned off, you must always wait one minute so that the dc-link capacitors can discharge. Do not remove the cover until this time has elapsed. All settings must only be entered by qualified personnel, paying particular attention to the safety precautions and warnings

Summary of the content on the page No. 13

3. Operating Information English (2) Using a combination of the internal potentiometer and a run/stop switch: (a) Connect a run/stop switch between DIN1 (pin 5) and P15+ (pin 8) on PL800 (see Figure 4a) if forward rotation is required. If reverse rotation is required instead, connect the switch to DIN2 (pin 6) instead of DIN1. IMPORTANT In either case, if a link has been fitted between pin 5 and pin 8 it must be removed before the run/stop switch is fitted. (b) Apply mains power. The green and

Summary of the content on the page No. 14

English 3. Operating Information 3.6 If the Motor Does Not Start Up Check the LEDs on the side of the inverter: ® LED State CombiDrive Status Green Yellow ® ON ON Mains power on, CombiDrive not running (STANDBY) ® ON OFF CombiDrive running, as per control commands (ON) Flashing Flashing Current limit warning ® Flashing ON CombiDrive overtemperature ON Flashing Motor overtemperature OFF ON Other fault (e.g. tripped) OFF Flashing Mains undervoltage OFF OFF Mains supply fault (e.g. faulty externa

Summary of the content on the page No. 15

3. Operating Information English 3.8 Closed Loop Control ® Closed loop control is only possible when an OPm2 or a serial link is connected to the CombiDrive . 3.8.1 General Description ® The CombiDrive provides a Proportional/Integral (PI) control function for closed loop control (see Figure 7). PI control is ideal for temperature or pressure control, or other applications where the controlled variable changes slowly or where transient errors are not critical. This control loop is not suitabl

Summary of the content on the page No. 16

English 4. Clear Text Display Module & System Parameters 4. CLEAR TEXT DISPLAY MODULE & SYSTEM PARAMETERS 4.1 Clear Text Display Module (OPm2) This section only applies for users who intend using the optional Clear Text Display module (OPm2) to ® control the operation of the CombiDrive . ® The OPm2 module provides a multi-language user-friendly interface to the CombiDrive . The display is menu- driven and provides information in simple text form. It also includes built-in context-sensitive He

Summary of the content on the page No. 17

4. Clear Text Display Module & System Parameters English 4.2 System Parameters ® The parameters listed here can only be accessed via the OPm2 or a serial link to the CombiDrive . If the ® CombiDrive is to be operated only using analogue control within the 0 - 50 Hz frequency range then access to these parameters is not required. Note: The control buttons on the OPm2 (RUN, REVERSE and JOG) are disabled by default and cannot be used until P007 has been set to ‘1’. Access to parameters is determi

Summary of the content on the page No. 18

English 4. Clear Text Display Module & System Parameters Parameter Function Range Description / Notes [Default] Ramp down time (seconds) 0 - 650.00 This is the time taken for the motor to decelerate from maximum frequency P003 • • • • [25.00] (P013) to standstill. Setting the ramp down time too short can cause the inverter to trip (fault code F001 - overvoltage). This is also the period for which DC injection braking is applied (see P073) Frequency f max 0 Hz Ramp down Time time (0 - 650 s) Sm

Summary of the content on the page No. 19

4. Clear Text Display Module & System Parameters English Parameter Function Range Description / Notes [Default] Keypad control 0 - 1 0 = The RUN, REVERSE and JOG buttons are disabled. Control is P007 [0] via digital inputs (see parameters P051 - P053). ∆ and ∇ may still be used to control frequency provided that P124 = 1 and a digital input has not been selected to perform this function. 1 = OPm2 buttons are enabled (can be individually disabled depending on the setting of parameters P121 - P12

Summary of the content on the page No. 20

English 4. Clear Text Display Module & System Parameters Parameter Function Range Description / Notes [Default] Automatic restart after fault 0 - 1 Automatic restart after fault: P018 • • • • [0] 0 = Disabled 1 = The inverter will attempt to restart up to 5 times after a fault. If the fault is not cleared after the 5th attempt, the inverter will remain in the fault state until reset. There is an increasing time delay between each restart attempt. Skip frequency bandwidth (Hz) 0 - 10.00 Frequen


Alternative user manuals
# User manual Category Download
1 Siemens ACCESS 9200 User manual Power Supply 42
2 Siemens M1 User manual Power Supply 249
3 Siemens Stober CombiDrive CM550/3 User manual Power Supply 6
4 Siemens Stober CombiDrive CM750/3 User manual Power Supply 1
5 Siemens MCC-3298 User manual Power Supply 7
6 Siemens Stober CombiDrive CM300/3 User manual Power Supply 1
7 Siemens MICROMASTER 440 User manual Power Supply 849
8 Siemens Stober CombiDrive CM220/3 User manual Power Supply 1
9 Siemens Stober CombiDrive CM150/3 User manual Power Supply 3
10 Sony AC U50A User manual Power Supply 5
11 Sony AC LS1 User manual Power Supply 2
12 Sony NP-FM30 User manual Power Supply 35
13 Sony NP FX101 User manual Power Supply 1
14 Sony NH-AAA-DA User manual Power Supply 2
15 3Com 3645A User manual Power Supply 0