TDK GENESYS 750W HALF RACK user manual

User manual for the device TDK GENESYS 750W HALF RACK

Device: TDK GENESYS 750W HALF RACK
Category: Power Supply
Manufacturer: TDK
Size: 1.99 MB
Added : 9/23/2014
Number of pages: 82
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for TDK GENESYS 750W HALF RACK. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with TDK GENESYS 750W HALF RACK.

For your convenience

If looking through the TDK GENESYS 750W HALF RACK user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual TDK GENESYS 750W HALF RACK on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual TDK GENESYS 750W HALF RACK to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
TDK GENESYS 750W HALF RACK User manual - Online PDF
Advertisement
« Page 1 of 82 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual TDK GENESYS 750W HALF RACK but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to TDK GENESYS 750W HALF RACK. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


TECHNICAL MANUAL FOR
TM
GENESYS 750W HALF RACK
Programmable DC Power Supplies
Document: 83-507-5002 Rev B



















TDK-Lambda Americas Inc.

405 Essex Road, Neptune, NJ 07753
Tel: (732) 922-9300
Fax: (732) 922-9334
Web: www.US.TDK-Lambda.com/HP

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Summary of the content on the page No. 4

GENESYS™ Manual Supplement FOR UNITS EQUIPPED WITH “IEMD” OPTION. ALSO REFER TO MANUAL 83-030-200 IEMD. 83-507-5002 Rev. B

Summary of the content on the page No. 5

TABLE OF CONTENTS WARRANTY……………………………………………………………………………………………. Pg. 1 SAFETY INSTRUCTIONS…………………………………………………………………………….. Pg. 2 GERMAN SAFETY INSTRUCTIONS………………………………………………………………… Pg. 4 Pg. 6 CHAPTER 1 GENERAL INFORMATION…………………………………………………………... 1.1 USER MANUAL CONTENT………………………………………………………………………. Pg. 6 1.2 INTRODUCTION…………………………………………………………………………………… Pg. 6 1.2.1 General description………………………………………………………………………….. Pg. 6 1.2.2 Models covered …………………………………………………………………………….

Summary of the content on the page No. 6

TABLE OF CONTENTS 3.9 CONNECTING THE LOAD……………………………………………………………………….. Pg. 18 3.9.1 Load Wiring………………………………………………………………………………….. Pg. 18 3.9.2 Current Carrying Capacity…………………………………………………………………. Pg. 18 3.9.3 Wire termination……………………………………………………………………….……. Pg. 19 3.9.4 Noise and Impedance Effects……………………………………………………………... Pg. 20 3.9.5 Inductive loads………………………………………………………………………………. Pg. 20 3.9.6 Making the load connections……………………………………………………………….

Summary of the content on the page No. 7

TABLE OF CONTENTS 5.15 PARALLEL OPERATION………………………………………………………….………….…. Pg. 41 5.15.1 Basic parallel operation……………………………………………………………………. Pg. 41 5.15.2 Advanced parallel operation………………………………………………………………. Pg. 42 5.16 DAISY-CHAIN SHUT-OFF CONNECTION……………………………………………………. Pg. 44 5.17 FRONT PANEL LOCKING………………………………………………………………………. Pg. 44 5.17.1 Unlocked front panel………………………………………………………………………. Pg. 45 5.17.2 Locked front panel…………………………………………………………………………. Pg.

Summary of the content on the page No. 8

TABLE OF CONTENTS 7.10.4 Addressed commands with response…………………………………………………… Pg. 60 7.10.5 Addressed commands without response……………………………………………….. Pg. 61 7.10.6 Status Control Commands……………………………………………………………….. Pg. 63 7.11 STATUS, ERROR AND SRQ REGISTERS……………………………………………….….. Pg. 63 7.11.1 General Description………………………………………………………………….……. Pg. 63 7.11.2 Conditional registers………………………………………………………………….…… Pg. 64 7.11.3 Service Request Enabled and

Summary of the content on the page No. 9

WARRANTY This TDK-Lambda Americas Inc. product is warranted against defects in materials and workmanship for a period of five years from date of shipment. During the warranty period, TDK-Lambda Americas Inc. will, at it’s option, either repair or replace products which prove to be defective. LIMITATION OF WARRANTY The warranty shall not apply to defects resulting from improper or inadequate usage or maintenance by the buyer, buyer s

Summary of the content on the page No. 10

SAFETY INSTRUCTIONS CAUTION The following safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built- in protections within. TDK-Lambda Americas Inc. shall not be liable for user’s failure to comply with these requirements. INSTALLATION CATEGORY TM The Genesys p

Summary of the content on the page No. 11

SAFETY INSTRUCTIONS ENVIRONMENTAL CONDITIONS TM The Genesys power supply series safety approval applies to the following operating conditions: *Indoor use *Ambient temperature: 0°C to 50°C *Maximum relative humidity: 90% (no condensation) *Altitude: up to 3000m *Pollution degree 2 CAUTION Risk of Electrical Shock Instruction manual symbol. The instrument will be marked with this symbol when it is necessary for the user to refer to the instruction manual. Indicates hazardous voltage. Indicates gr

Summary of the content on the page No. 12

SICHERHEITS-INSTALLATIONS ANWEISUNGEN Vorsicht Vor Anschluss an das Netz ist die Aufstellanleitung wie nachstehend beschrieben zu beachten. Die nachstehenden Sicherheitsanweisugen mussen während aller Phasen des Betriebes, des Services und der Reparatur dieser Ausrustung beachtet werden. Alle notwendigen Bedingungen die sicherstellen, dass die Einrichtung zu keiner Gefahr im Sinne dieser Norm führen kann, sind in diesem Handbuch beschrieben. TDK-Lambda Americas Inc. ist nich verantwortl

Summary of the content on the page No. 13

Anderungen and Bauteileersatz Ersatzteilaustausch – und Anderungen durfen nur von autorisiertem TDK-Lambda Americas Inc. SERVICE-PERSONEN durchgefuhrt werden. Fur Reparaturen oder Anderungen ist das Gerat zur TDK-Lambda Americas Inc. Service-Niederlassung zu retournieren. SICHERHEITS-HINWEISE Umweltbedingungen TM Die Genesys Stromversorgungs-Serie ist gemassden Sicherheitsabnahmen fur folgende Betriebsbedingungen zugelassen. *Stationare Einrichtungen in Gebauden. *Umgebungstemperatu

Summary of the content on the page No. 14

CHAPTER 1 GENERAL INFORMATION 1.1 USER MANUAL CONTENT This User’s Manual contains the operating instructions, installation instructions and specifications TM of the Genesys GENH 750W power supply series. The instructions refer to the standard power supplies, including the built-in RS232/RS485 serial communication. For information related to operation with the optional IEEE programming, refer to User’s Manual for Power Supply IEEE Programming Interface. (TDK-Lambda Americas Inc. P/N 83-

Summary of the content on the page No. 15

* Parallel operation (Master/Slave) with Active current sharing. * Remote sensing to compensate for voltage drop of power leads. * External Analog Programming and Monitoring standard (0-5V or 0-10V, user selectable). * Cooling fan speed control for low noise and extended fan life. * Zero stacking-no ventilation holes at the top and bottom surface of the power supply. * Optional GPIB interface (SCPI compatible). * Optional Isolated Analog programming/monitoring (0-5V or 0-10V, user sele

Summary of the content on the page No. 16

1.2.9 Cooling and mechanical construction TM The Genesys series is cooled by internal fans. At the installation, care must be taken to allow free airflow into the power supply via the front panel and out of the power supply via the rear TM panel. The Genesys power supplies have a compact and lightweight package, which allows easy installation and space saving in the application equipment. CAUTION Observe all torque guidelines within this manual. Applying more torque may damage uni

Summary of the content on the page No. 17

CHAPTER 2 SPECIFICATIONS 2.1 OUTPUT RATING MODEL GEN 6-100 8-90 12.5-60 20-38 30-25 40-19 – 60-12.5 80-9.5 100-7.5 150-5 300-2.5 600-1.3 1.Rated output voltage (*1) V 6 8 12.5 20 30 40 – 60 80 100 150 300 600 2.Rated output current 750W (*2) A 100 90 60 38 25 19 – 12.5 8.5 7.5 5 2.5 1.3 3.Rated output power 750W W 600 720 750 760 750 760 – 750 760 750 750 750 780 MODEL GEN 6-200 8-180 12.5-120 20-76 30-50 40-38 50-30 60-25 80-19 100-15 150-10 300-5 600-2.6 1.Rated output voltage (*1) V

Summary of the content on the page No. 18

2.6 PROGRAMMING AND READBACK (RS232/485, Optional IEEE Interface) 1. Vout programming accuracy – 0.05% + 0.05% of rated output voltage. 2. Iout programming accuracy (*13) – 0.1% of actual output current + 0.1% of rated output current (for Iout >0.4% of rated Iout to 100% of rated Iout). 0.1% of actual output current +0.4% of rated output current (for Iout <0.4% of rated Iout to 0.4% of rated Iout). 3. Vout programming resolution. – 0.012% of full scale. 4. Iout programming resolution – 0.012

Summary of the content on the page No. 19

NOTES: *1: Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage. *2: Minimum current is guaranteed to maximum 0.4% of the rated output current. *3: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be described as 100-240Vac (50/60Hz). *4: At 100/200V input voltage and maximum output power. *5: From 85i132Vac or 170i265Vac, constant load. *6: From No-load to Full-load, constant input voltage. Measured at the sensing po

Summary of the content on the page No. 20

TM 2.13 GENESYS GENH 750W POWER SUPPLIES OUTLINE DRAWINGS 12 83-507-5002 Rev. B


Alternative user manuals
# User manual Category Download
1 TDK FPS-T1U User manual Power Supply 0
2 TDK 500A User manual Power Supply 2
3 TDK FPS1000-12 User manual Power Supply 1
4 TDK FPS1000-24 User manual Power Supply 8
5 TDK FPS-S1U User manual Power Supply 0
6 TDK FPS1000-48 User manual Power Supply 3
7 TDK GENESYS 1500W User manual Power Supply 35
8 TDK GENESYS 750W User manual Power Supply 1
9 TDK ZACT-ME Series User manual Power Supply 0
10 TDK FPS1000-32 User manual Power Supply 5
11 TDK iHA48060A012V User manual Power Supply 0
12 TDK Supereta iQN series User manual Power Supply 0
13 TDK /DC to DC Converter/CCFL Inverter User manual Power Supply 14
14 TDK ZMG-11 User manual Power Supply 0
15 TDK ZMG2201-M User manual Power Supply 3
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2