National Instruments NI PXI-1006 user manual

User manual for the device National Instruments NI PXI-1006

Device: National Instruments NI PXI-1006
Category: Power Supply
Manufacturer: National Instruments
Size: 0.13 MB
Added : 12/14/2013
Number of pages: 5
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI PXI-1006. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI PXI-1006.

For your convenience

If looking through the National Instruments NI PXI-1006 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI PXI-1006 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI PXI-1006 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI PXI-1006 User manual - Online PDF
Advertisement
« Page 1 of 5 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI PXI-1006 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI PXI-1006. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

NI PXI-1006 Power Supply Shuttle
User Guide
The NI PXI-1006 power supply shuttle is a replacement part for the
PXI-1006 chassis.
To minimize downtime caused by a power supply failure, the PXI-1006
chassis has a modular power supply shuttle. This power supply shuttle
includes the chassis power supply, cooling fans, and fan-control circuitry.
Key features of the power supply shuttle include the following:
• Universal AC input with automatic voltage and frequency ranging
 Over-current protect

Summary of the content on the page No. 2

❑ NI PXI-1006 User Manual (provided with the chassis; also available at ni.com/support) ❑ No. 1 Phillips screwdriver Description Refer to Figure 1 to locate user-accessible components on the power supply shuttle. 5 6 4 AUTO 3 2 1 1 Chassis Ground Screw 4 Mounting Screws (10x) 2 Universal AC Input 5 Fan Speed Selector 3 Circuit Breaker 6 Remote Power Status and Inhibit Connector Figure 1. PXI-1006 Power Supply Shuttle Rear Panel Installation and Maintenance The information in this section is f

Summary of the content on the page No. 3

Caution Never connect the AC power cable to the power supply shuttle until you install it in a PXI-1006 chassis. Do not use, test, or configure the power supply shuttle outside of a chassis. The power supply shuttle is a replacement part for the PXI-1006 chassis. The NI PXI-1006 User Manual contains other chassis service procedures. The chassis includes a hardcopy of the NI PXI-1006 User Manual. Additionally, you can download a softcopy from ni.com/support. Removal Before attempting to repl

Summary of the content on the page No. 4

Connecting Safety Ground Caution The power supply shuttle is designed with a three-position NEMA 5-15 jack that connects the ground line to the chassis ground. To minimize shock hazard, make sure the electrical power outlet you use to power the chassis has an appropriate earth safety ground. If your power outlet does not have an appropriate ground connection, you must connect the premise safety ground to the chassis ground screw. Refer to Figure 1 to locate the chassis ground screw. Complete

Summary of the content on the page No. 5

DC Output Maximum usable power......................... 600 W DC current capacity (I ) MP Voltage I (Steady-State Current) MP +3.3 V 60 A +5 V 60 A +12 V 9 A –12 V 1.8 A Load regulation Voltage Regulation +3.3 V 0.4% or 20 mV max +12 V 0.4% or 20 mV max +5 V 0.4% or 20 mV max –12 V 0.4% or 20 mV max Maximum ripple and noise .................... 1% ripple, 1% noise 20 MHz bandwidth Over-current protection.......................... 105–140% of rated output current; automatic recovery Over-voltag


Alternative user manuals
# User manual Category Download
1 National Instruments FP-PS-4 User manual Power Supply 2
2 National Instruments NI PXI-1042 User manual Power Supply 11
3 National Instruments NI PXI-1042 Series User manual Power Supply 19
4 National Instruments PXI-1045 User manual Power Supply 6
5 Sony AC U50A User manual Power Supply 5
6 Sony AC LS1 User manual Power Supply 2
7 Sony NP-FM30 User manual Power Supply 35
8 Sony NP FX101 User manual Power Supply 1
9 Sony NH-AAA-DA User manual Power Supply 2
10 3Com 3645A User manual Power Supply 0
11 3Com 3CNJPSE24 User manual Power Supply 2
12 3Com COREBUILDER 5000 User manual Power Supply 0
13 3Com 3646A User manual Power Supply 0
14 3Com External PoE Power System PSE2500-A3 User manual Power Supply 1
15 Sony AC E45HG User manual Power Supply 10