MGE UPS Systems PULSAR 1500 user manual

User manual for the device MGE UPS Systems PULSAR 1500

Device: MGE UPS Systems PULSAR 1500
Category: Power Supply
Manufacturer: MGE UPS Systems
Size: 3.99 MB
Added : 1/25/2014
Number of pages: 196
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MGE UPS Systems PULSAR 1500. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MGE UPS Systems PULSAR 1500.

For your convenience

If looking through the MGE UPS Systems PULSAR 1500 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MGE UPS Systems PULSAR 1500 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MGE UPS Systems PULSAR 1500 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MGE UPS Systems PULSAR 1500 User manual - Online PDF
Advertisement
« Page 1 of 196 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MGE UPS Systems PULSAR 1500 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MGE UPS Systems PULSAR 1500. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.mgeups.com MGE UPS SYSTEMS
Pulsar Evolution
1500 /1500 Rack
1100 /1100 Rack
800 /800 Rack
500 Rack
Installation and user
manual
English
Français
Deutsch
Italiano
Español
Nederlands
3400711700/AB
W
O
N
U
O
Y
P
O
T
S
L
L
I
W
G
N
I
H
T
O
N

Summary of the content on the page No. 2

www.mgeups.com MGE UPS SYSTEMS Pulsar Evolution 1500 /1500 Rack 1100 /1100 Rack 800 /800 Rack 500 Rack Installation and user manual 34007117EN/AB - Page 1 W O N U O Y P O T S L L I W G N I H T O N

Summary of the content on the page No. 3

Page 2 - 34007117EN/AB

Summary of the content on the page No. 4

Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar Evolution range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar Evolution a reference in environmental protection include: w the eco-design approach used in product deve

Summary of the content on the page No. 5

Foreword Using this document Information may be found in two ways, using: w the contents; w the index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Page 4 - 34007117EN/AB

Summary of the content on the page No. 6

Contents 1. Presentation 1.1 Overall view ................................................................................................................................. 7 Tower models .................................................................................................................................. 7 Rack models ................................................................................................................................... 7 1.2 Back ........................

Summary of the content on the page No. 7

Contents 4. Maintenance 4.1 Trouble-shooting......................................................................................................................... 22 4.2 Replacement of the battery module .......................................................................................... 23 Tower models ................................................................................................................................ 23 Rack models ..........................................

Summary of the content on the page No. 8

1. Presentation 1.1 Overall view Tower models Dimensions in mm (W x H x D) D Evolution 800 150 x 237 x 415 Evolution 1100 150 x 237 x 415 Evolution 1500 150 x 237 x 483 Weight in kg H Evolution 800 10.5 Evolution 1100 11.5 Evolution 1500 15 W Rack models Dimensions in mm (W x H x D) D Evolution 500 Rack 438 x 43.5 x 353 Evolution 800 Rack 438 x 43.5 x 499 Evolution 1100 Rack 438 x 43.5 x 499 H Evolution 1500 Rack 438 x 43.5 x 522 (19") (1U) Weight in kg W Evolution 500 Rack 9 Evolution 800 Rack

Summary of the content on the page No. 9

1. Presentation 1.2 Back Pulsar Evolution 800 / 1100 / 1500 Pulsar Evolution 1500: USB communications port. 1 7 4 2 RS232 communications port. 8 3 Data-line protection. 5 4 Slot for communications-card option. 2 2 5 Outlets for direct connection of 6 1 1 protected equipment. 6 Programmable outlets (1 and 2). 3 7 Input circuit-breaker. 8 Socket for connection to AC-power Pulsar Evolution 500 / 800 / 1100 Rack source. 1 2 87 5 6 3 2 1 4 Pulsar Evolution 1500 Rack 1 2 48723 1 56 Page 8 - 34007117EN

Summary of the content on the page No. 10

1. Presentation 1.3 Control panel 10 Iluminated ON/OFF button for the outlets. 11 Operation on battery power. 12 UPS fault. Battery fault. 13 Overload. 14 Group 1 programmable outlets supplied with power. 1 2 15 Group 2 programmable outlets supplied with power. 16 Booster or fader mode. 17 Bargraph indicating percent load at output. % % 18 Bargraph indicating the battery charge level. 76 to 100%. 51 to 75%. 26 to 50%. 0 to 25%. 34007117EN/AB - Page 9

Summary of the content on the page No. 11

2. Installation 2.1 Unpacking and parts check Tower models 20 21 22 30 23 24 Two cords for connection of the protected equipment. 20 RS232 communications cable. 21 USB communications cable. 22 CD-ROM with the Solution-Pac and UPS Driver software. 23 Product documentation. 24 Page 10 - 34007117EN/AB P U L S A R Evolution 1 1 0 0

Summary of the content on the page No. 12

2. Installation Rack models 20 21 22 23 25 24 26 Two cords for connection of the protected equipment. 20 21 RS232 communications cable. 22 USB communications cable. CD-ROM with the Solution-Pac and UPS Driver software. 23 Product documentation. 24 Telescopic rails for mounting in 19" bay with mounting hardware. 25 Securing system for equipment power cords. 26 34007117EN/AB - Page 11 P U L S A R Evolution 1500 Rack

Summary of the content on the page No. 13

2. Installation 2.2 Installation Tower models Page 12 - 34007117EN/AB P U L S A R Evolution 1 1 0 0 P U L S A R Evolution 1 1 0 0

Summary of the content on the page No. 14

2. Installation 800/1100/1500 Rack models Follow steps 1 to 6 for rack mounting of the UPS on the rails. 2 1 6 2 2 4 3 2 5 6 5 3 The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. 34007117EN/AB - Page 13 P U L S A R Evolution 1500 Rack

Summary of the content on the page No. 15

2. Installation 500 Rack model 2 1 3 1 3 Page 14 - 34007117EN/AB P U L S A R Evolution 1500 Rack P U L S A R Evolution 1500 Rack 1500 Rack P U L S A R Evolution

Summary of the content on the page No. 16

2. Installation 2.3 Connecting the protected equipment A Pulsar Evolution 1500 tower UPS has been used below to illustrate the instructions. The principle is the same for all the other tower and rack models. Check that the indications on the rating plate on the back of the UPS correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. 1 - Remove the power cord supplying the equipment to be protected. 8 (1) 2 - Connect the power co

Summary of the content on the page No. 17

2. Installation A Pulsar Evolution 1500 tower UPS has been used below to illustrate the instructions. The principle is the same for all the other tower and rack models. 2.4 Connection to the RS232 or USB communications port (optional) The RS232 and USB 21 communications ports cannot operate simultaneously. 1 - Connect the RS232 21 or USB 22 communications cable to the serial port or RS232 the USB port on the computer. 2 22 1 2 - Connect the other end of the communications cable 21 or 22 t

Summary of the content on the page No. 18

2. Installation 2.6 Installation of the communications-card option 1 - Remove the slot cover 4 secured by 4 two screws. Restricted-access slot for 2 - Insert the card in the slot. the communications card 3 - Secure the cover with the two screws. RS232 DATA LINE PROTECTION IN OUT It is not necessary to shut down the UPS to install the communications card. This operation must be carried out by qualified personnel. 34007117EN/AB - Page 17

Summary of the content on the page No. 19

3. Operation 3.1 Start-up Press the ON / OFF button 10 . The buzzer beeps and all the LEDs come ON. The buzzer beeps twice during the self-test, then button 10 remains 10 ON, indicating that the outlets are supplied with power. - AC power is present: Only button 10 is ON. The protected 11 equipment is supplied by the AC-power source. 12 - AC power is absent: Button 10 and LED 11 are ON. The protected 1 2 equipment is supplied by the UPS, operating on battery power. % % All the connected

Summary of the content on the page No. 20

3. Operation 3.3 Operation on battery power (following failure of AC-input power) Transfer to battery power The AC-input power is out of tolerances, LED 11 goes ON. During operation on battery power, the buzzer beeps every ten seconds. The equipment connected to the UPS is supplied by the battery. 11 1 2 % % Threshold for the low-battery warning When the threshold is reached, the buzzer beeps every three seconds. The low-battery warning threshold can be set by the user, with the ÒUPS DriverÓ


Alternative user manuals
# User manual Category Download
1 MGE UPS Systems 11+ User manual Power Supply 46
2 MGE UPS Systems 1100 Tower User manual Power Supply 21
3 MGE UPS Systems 1200 User manual Power Supply 27
4 MGE UPS Systems 1100 User manual Power Supply 64
5 MGE UPS Systems 1100 Rack User manual Power Supply 21
6 MGE UPS Systems 14+ User manual Power Supply 40
7 MGE UPS Systems 1500 Rack User manual Power Supply 18
8 MGE UPS Systems 12280 kVA User manual Power Supply 0
9 MGE UPS Systems 2000 User manual Power Supply 31
10 MGE UPS Systems 12 kVA User manual Power Supply 7
11 MGE UPS Systems 1500 Tower User manual Power Supply 16
12 MGE UPS Systems 1500C User manual Power Supply 35
13 MGE UPS Systems 18/280 kVA User manual Power Supply 4
14 MGE UPS Systems 2000 RT 2U User manual Power Supply 59
15 MGE UPS Systems 300 User manual Power Supply 82
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2