MGE UPS Systems PULSAR 1000 user manual

User manual for the device MGE UPS Systems PULSAR 1000

Device: MGE UPS Systems PULSAR 1000
Category: Power Supply
Manufacturer: MGE UPS Systems
Size: 3.98 MB
Added : 1/25/2014
Number of pages: 126
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MGE UPS Systems PULSAR 1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MGE UPS Systems PULSAR 1000.

For your convenience

If looking through the MGE UPS Systems PULSAR 1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MGE UPS Systems PULSAR 1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MGE UPS Systems PULSAR 1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MGE UPS Systems PULSAR 1000 User manual - Online PDF
Advertisement
« Page 1 of 126 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MGE UPS Systems PULSAR 1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MGE UPS Systems PULSAR 1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.mgeops.com
ENGLISH
FRANÇAIS
ESP AÑOL
POR TUGUESE
Pulsar
700 – 1000 – 1500
1000 RT2U – 1500 RT2U
EXB 1000/1500
EXB 1000/1500 RT2U
Installation and User Manual
Manuel d’installation et d’utilisation
Manual de instalación y de usuario
Manual de instalação e do usuário

Summary of the content on the page No. 2

Summary of the content on the page No. 3

ENGLISH Installation and User Manual Pulsar Installation and User Manual Revision History Pulsar Installation and User Manual, 86-86700-00 Revision: A01 ECN#: 005282 5/2007 Copyright © 2007 MGE Office Protection Systems All rights reserved. Printed in U.S.A. MGE Office Protection Systems 13 Whatney, Suite #101 Irvine, CA 92618 (949) 268-2800 For Technical Support, Customer Care Center, or Customer FAQ, please visit our website: www.mgeops.com or call (800) 279-7776 86-86700-00 A01

Summary of the content on the page No. 4

ENGLISH Pulsar 86-86700 A01

Summary of the content on the page No. 5

ENGLISH Contents Introduction..........................................................................................................................................1 Symbol Usage ....................................................................................................................................3 1. Presentation 1.1 Standard Positions..........................................................................................................1 — 1 1.2 Rear Panels..................

Summary of the content on the page No. 6

Pulsar ENGLISH 86-86700-00 A01

Summary of the content on the page No. 7

ENGLISH Introduction Thank you for selecting an MGE Office Protection Systems product to protect your electrical equipment. Pulsar has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS (Uninterruptible Power System). Before installing Pulsar, please read the booklet on the required safety instructions. Then follow the indications in this manual. To discover the entire range of MGE Office Protection

Summary of the content on the page No. 8

Pulsar ENGLISH Federal Communication Commission (FCC) statement NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, ma

Summary of the content on the page No. 9

ENGLISH Presentation 1.1 Standard Positions Tower Position Dimensions (H x W x D) in mm / inches 242 x 158 x 400 / Pulsar 700 9.52 x 6.22 x 15.74 242 x 158 x 400 / Pulsar 1000 9.52 x 6.22 x 15.74 438 x 86.5 x 480 / Pulsar 1000 RT2U 17.24 x 3.4 x 18.9 242 x 158 x 450 / Pulsar 1500 9.52 x 6.22 x 17.71 438 x 86.5 x 480 / Pulsar 1500 RT2U 17.24 x 3.4 x 18.9 Pulsar EXB 242 x 158 x 400 / 1000/1500 9.52 x 6.22 x 15.74 Pulsar EXB 440 x 86.5 x 480 / 1000/1500 RT2U 17.32 x 3.4 x 18.9 Rack Position

Summary of the content on the page No. 10

Pulsar ENGLISH 1.2 Rear Panels Pulsar 700 / 1000 / 1500 (1) USB communication port (2) RS232 and dry contacts communication port 4 2 (3) Connector for automatic recognition of a battery EXB module (except on Pulsar 700) 1 (4) Slot for optional communication card 8 (5) Connector for remote ON/OFF and RPO (Remote Power Off) control (6) Connector for battery EXB module, except on 5 Pulsar 700 3 (7) Group of programmable outlets for connection of 6 equipment (8) Group of outlets for connection

Summary of the content on the page No. 11

ENGLISH Installation and User Manual Pulsar EXB 1000/1500 RT2U (optional battery module) 1.3 Control Panel (20) Load protected LED (21) Downgraded operation LED (22) Load not protected LED (23) Alphanumeric display (24) Escape (cancel) button (25) Scroll button (26) Enter (confirm) button (27) ON/OFF button for UPS and outlets 86-86700-00 A01 Presentation 1 — 3

Summary of the content on the page No. 12

Pulsar ENGLISH (This page left blank intentionally) 1 — 4 86-86700-00 A01

Summary of the content on the page No. 13

ENGLISH Installation 2.1 Unpacking and Contents Check (30) Pulsar 700, 1000, 1500 (37) Mounting kit for 19-inch bays (31) Pulsar 1000 RT2U, 1500 RT2U (38) 2 supports for the upright position (RT model only) (33) RS232 communication cable (41) NMC communication card (optional) (34) USB communication cable (36) Solution-Pac CD-ROM and documentation Elements supplied depending on the version or option Packing materials must be disposed of in compliance with all local regulations concerning wa

Summary of the content on the page No. 14

Pulsar ENGLISH 2.2 Installation of the RT Model in Tower Position 2.3 Installation of the RT Model in a Rack It is advised to install the battery EXB module(s) at the lowest position in the rack, then install the UPS above. Follow steps 1 to 4 for module mounting on the rails. The rails and necessary hardware (37) are supplied by MGE Office Protection Systems. i 2 — 2 Installation 86-86700-00 A01

Summary of the content on the page No. 15

ENGLISH Installation and User Manual 2.4 Communication Ports Connection of RS232 or USB communication port (optional) The RS232 and USB communication ports cannot operate simultaneously. Tower model 1. Connect the RS232 (33) or USB (34) communica- tion cable to the serial or USB port on the computer equipment. 2. Connect the other end of the communication cable (33) or (34) to the USB (1) or RS232 (2) communication port on the UPS. The UPS can now communicate with MGE Office Protection Systems

Summary of the content on the page No. 16

Pulsar ENGLISH Installation of optional communication cards (optional) Tower model RT model It is not necessary to shutdown the UPS before installing a communication card. (4): Slot, with restricted access, for the communications- card. 1. Remove the UPS cover (4) secured by screws. 2. Insert the communication card in the slot. 3. Put the UPS cover back in place using the screws. 2.5 Connection to the Communication Port by Contact ◗ Pin 2, 3, 5 and 6: not used, ◗ Pin 1: operation on automat

Summary of the content on the page No. 17

ENGLISH Installation and User Manual 2.6 Connections with a FlexPDU (Power Distribution Unit) module (optional) 1. Connect the UPS socket (9) to the AC-power source using the power cable from the equip- ments to be protected. 2. Connect the input socket on the FlexPDU module (48) to the UPS outlet (7) or (8). The cable and the connectors are marked in red. 7 8 9 3. Connect the equipment to the outlets (45) and (46) on the FlexPDU module. These outlets differ, depending on the version of the Flex

Summary of the content on the page No. 18

Pulsar ENGLISH (This page left blank intentionally) 2 — 6 86-86700-00 A01

Summary of the content on the page No. 19

ENGLISH Operation 3.1 Start-Up and Normal Operation For the initial start, AC power must be present to detect any wiring errors. Subsequently, the UPS can start even if AC i power is not present. Press button (27) for approximately 1 second. The connected devices are protected by the UPS. ◗ LED (20) is ON. If LED (22) is ON, a fault has occurred (see the "Troubleshooting" section). ◗ During normal operation, the scroll button (25) may be used to read UPS measurements (AC input voltage, opera

Summary of the content on the page No. 20

Pulsar ENGLISH End of battery backup time ◗ All the LEDs go OFF. ◗ The audio alarms stops. The UPS is completely shut down. 3.3 Return of AC Power Following an outage, the UPS restarts automatically when AC power returns (unless the restart function was disabled via UPS personalization) and the load is again supplied. 3.4 UPS Shutdown Press button (27) for approximately 1 second. The devices connected to the UPS are no longer supplied. 3.5 Using the UPS Remote Control Functions Pulsar has


Alternative user manuals
# User manual Category Download
1 MGE UPS Systems 11+ User manual Power Supply 46
2 MGE UPS Systems 1100 Tower User manual Power Supply 21
3 MGE UPS Systems 1200 User manual Power Supply 27
4 MGE UPS Systems 1100 User manual Power Supply 64
5 MGE UPS Systems 1100 Rack User manual Power Supply 21
6 MGE UPS Systems 14+ User manual Power Supply 40
7 MGE UPS Systems 1500 Rack User manual Power Supply 18
8 MGE UPS Systems 12280 kVA User manual Power Supply 0
9 MGE UPS Systems 2000 User manual Power Supply 31
10 MGE UPS Systems 12 kVA User manual Power Supply 7
11 MGE UPS Systems 1500 Tower User manual Power Supply 16
12 MGE UPS Systems 1500C User manual Power Supply 35
13 MGE UPS Systems 18/280 kVA User manual Power Supply 4
14 MGE UPS Systems 2000 RT 2U User manual Power Supply 59
15 MGE UPS Systems 300 User manual Power Supply 82
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2