MGE UPS Systems GES-302L user manual

User manual for the device MGE UPS Systems GES-302L

Device: MGE UPS Systems GES-302L
Category: Power Supply
Manufacturer: MGE UPS Systems
Size: 0.11 MB
Added : 1/25/2014
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MGE UPS Systems GES-302L. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MGE UPS Systems GES-302L.

For your convenience

If looking through the MGE UPS Systems GES-302L user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MGE UPS Systems GES-302L on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MGE UPS Systems GES-302L to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MGE UPS Systems GES-302L User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MGE UPS Systems GES-302L but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MGE UPS Systems GES-302L. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Always “On” UPS Systems Inc.
GES L-Series – Single Phase Input, Single Phase Output
Uninterruptible Power Supply
USER MANUAL
Version 1.4
GES-801L, GES-102L, GES-152L, GES-202L, GES-302L
Line Interactive (True Sine Wave):
800VA, 1000VA, 1500VA, 2000VA, 3000VA

Extended Run-Time Battery Banks
Available on All Models

Summary of the content on the page No. 2

Always “On” UPS Systems Inc.

Summary of the content on the page No. 3

Always “On” UPS Systems Inc. SAVE THESE INSTRUCTIONS This manual contains important instructions for the GES-801L, GES-102L, GES-152L, GES-202L, GES-302L and should be followed during installation and maintenance of the UPS and batteries. The UPS contains voltages that are potentially hazardous. Please contact our dealers or qualified personnel for service. Servicing of the batteries should be performed or supervised by personnel knowledgeable with batteries and the required precaut

Summary of the content on the page No. 4

Always “On” UPS Systems Inc. TABLE OF CONTENTS INTRODUCTION ........................................................................................................................................ 5 SAFETY INSTRUCTIONS......................................................................................................................... 6 PRESENTATION ...........................................................................

Summary of the content on the page No. 5

Always “On” UPS Systems Inc. Introduction The L-Series is a Line Interactive UPS system that includes the newest and latest technology enhancements. The Line Interactive technology with AVR function (on- line voltage boost-up & buck-down) allows for a wide input voltage range of 90 to 150VAC. The L-Series UPS is the ideal protection for microprocessor controlled loads. With the utility power connected, the charger begins to operate immediately, charging the battery. In the event of a

Summary of the content on the page No. 6

Always “On” UPS Systems Inc. Safety Instructions The UPS has its own internal energy source (batteries), therefore the output receptacles may have electricity present even though the UPS is disconnected from the utility power. The DC voltage provided from the internal batteries are as follows: a) GES-801L 24VDC d) GES-202L 48VDC b) GES-102L 24VDC e) GES-302L 48VDC c) GES-152L 36VDC Isolated Ground Wire refers to the bare wire connecting electrical equipment to ground. The isola

Summary of the content on the page No. 7

Always “On” UPS Systems Inc. Presentation Front Panel 1. POWER bar graph (BATTERY CHARGE/LINE VOLTAGE) This displays the present battery charge as a percentage of battery capacity. It also displays the utility line voltage. 2. LOAD bar graph This displays the amount of power required by the load as a percentage. 3. "OVERLOAD" indicator (RED LED) This LED lights when the load(s) connected to the UPS exceed the UPS's capacity. See Section 6.3 for solution to this problem. 4. "BUCK

Summary of the content on the page No. 8

Always “On” UPS Systems Inc. Rear Panel 11. TELEPHONE/MODEM/ETHERNET SURGE PROTECTION Surge protection for telephone line, modem line, and 10BaseT line to maintain a completely safe connection for INTERNET/INTRANET service. 12. EXTERNAL BATTERY PACK CONNECTOR (optional) Allows for extended runtime. Caution: Use only factory supplied or authorized connecting cable for external battery pack! 13. SNMP INTERFACE PORT (optional) This option will allow the UPS to be connected direct

Summary of the content on the page No. 9

Always “On” UPS Systems Inc. 16. INPUT CIRCUIT BREAKER It trips when the connected loads exceed the protected receptacle's capacity. The center plungers of the circuit breakers extend when tripped. 17. SITE WIRING FAULT INDICATORS (RED LED) It illuminates when the UPS is connected to an improperly wired AC power outlet. Note: This device is available on 120 VAC model only. 18. COMPUTER INTERFACE Provides both RS-232 and relay signal to support NOVELL, UNIX, DOS, WINDOWS and other

Summary of the content on the page No. 10

Always “On” UPS Systems Inc. Installation Unpacking and Inspection Examine the packaging for damage. Inform the carrier immediately if and/or when damage is noticed. Retain the packaging for future use. Placement Install the UPS in a protected area with adequate airflow and free of excessive dust. Do not operate the UPS where the temperature and humidity is outside the specified limits. Connect Computer Interface (optional) UPSilon 2000 (or selected option) and an interface kit c

Summary of the content on the page No. 11

Always “On” UPS Systems Inc. Connecting the Telephone/Modem/Ethernet Lines Connect a telephone line, modem line, or 10BaseT line into the telephone/modem/Ethernet surge protection sockets on the back of the UPS. The RJ-45/RJ-11 modular sockets accept standard single line telephone connections and 10BaseT connectors. This connection will require another length cable. Note: This connection is optional. It is not necessary to use this with the UPS. Caution: The line current limiting fea

Summary of the content on the page No. 12

Always “On” UPS Systems Inc. Operation Switching “On” the UPS With the UPS plugged in, press and hold the “ON/TEST” button for at least 1 second to switch the UPS on. The UPS will perform a self-test each time it is switched on. Note: When switched off, and still plugged into utility, the UPS maintains the battery charge and will respond to commands received through the computer interface port. Switching “Off” the UPS Press and hold the “OFF” button until the "LINE NORMAL" or "BAC

Summary of the content on the page No. 13

Always “On” UPS Systems Inc. Battery Charge Bar Graph This 5 LED display indicates the present charge of the UPS's batteries as a percentage of the total battery capacity. When all five LED’s are lit, the batteries are fully charged. When only two of the LED’s are lit, the batteries can supply less than two minutes of power to the load. Cold Start When the UPS is off, and there is no utility power, use the cold start feature to apply power to the loads from the UPS's battery. Press an

Summary of the content on the page No. 14

Always “On” UPS Systems Inc. Software Options UPSilon 2000 Software The UPSilon 2000 software utilizes standard RS-232 interface to perform monitoring functions, and provides an orderly shutdown of a computer system in the event of power failure. Moreover, UPSilon 2000 displays all the diagnostic symptoms through a graphical interface, such as Voltage, Frequency, Battery Level, etc. The software is available for DOS, Windows 3.x, Windows 95/98/00 & Windows NT V3.5 or later, FreeBSD,

Summary of the content on the page No. 15

Always “On” UPS Systems Inc. Computer Interface Port The computer interface port has the following characteristics: The communication port on the back of the UPS may be connected to a host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UPS. Its major functions include the following: 1. The ability to broadcast a warning when the power fails. 2. The ability to close any open files before the battery reserves are exhausted. 3

Summary of the content on the page No. 16

Always “On” UPS Systems Inc. Battery Replacement Your batteries should run anywhere from 3-5 years before they need to be replaced. Please follow the instructions below for easy, trouble free, battery replacement. 1. Turn the UPS off (follow procedure previously mentioned) 2. Unplug the UPS from utility power source and disconnect all connected loads. 3. Disconnect AC power cord from unit. 4. Using a phillips screw driver, unscrew the screws holding the top of the unit to the botto

Summary of the content on the page No. 17

Always “On” UPS Systems Inc. Troubleshooting Please follow the guidelines below for solutions to common problems: Check UPS input plug and wiring. Check UPS input voltage. Please prepare the information as follows for service personnel: UPS model number and serial number Description of problem(s) in detail. General Problems Problems Possible causes Solution Fuse/Breaker at back panel open Replace Fuse/Switch breaker on UPS has no reaction No AC input Check AC power

Summary of the content on the page No. 18

Always “On” UPS Systems Inc. Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least eight (8) hours. Remove any accessories from the accessory slot and disconnect any cables connected to the computer interface port to avoid unnecessary drain on the battery. Extended Storage During extended storage periods in environments where the ambient temperature is -15 to +30°C (+5 to +8

Summary of the content on the page No. 19

Always “On” UPS Systems Inc. Battery Bank Installation Install up to 8 battery banks per L Series UPS following the instructions below. 1 2 3 4 BLACK RED Caution: Make sure the UPS is shutdown and unplugged before connecting additional Battery Packs (refer to Switching the UPS “Off” section, page 11) 1. Locate the external battery connector located at the rear of the UPS. 2. Make sure you are connecting the connector correctly or

Summary of the content on the page No. 20

Always “On” UPS Systems Inc. Specifications Specification MODEL NO. GES-801L GES-102L GES-152L GES-202L GES-302L Comparison MAXIMUM CAPACITY 800VA / 560W 1kVA / 700W 1.5kVA / 1050W 2kVA / 1400W 3kVA / 2100W GENERAL UPC ORDER CODE 825433 22100 825433 22200 825433 22300 825433 22400 825433 22500 NOMINAL VOLTAGE 120VAC (220 optional) INPUT VOLTAGE RANGE + / - 25% FREQUENCY RANGE 50 or 60 Hz auto-sensing + / - 5% NOMINAL VOLTAGE 120VAC AUTO VOLTAGE REGULATION +15% for 90 - 109VAC


Alternative user manuals
# User manual Category Download
1 MGE UPS Systems 11+ User manual Power Supply 46
2 MGE UPS Systems 1100 Tower User manual Power Supply 21
3 MGE UPS Systems 1200 User manual Power Supply 27
4 MGE UPS Systems 1100 User manual Power Supply 64
5 MGE UPS Systems 1100 Rack User manual Power Supply 21
6 MGE UPS Systems 14+ User manual Power Supply 40
7 MGE UPS Systems 1500 Rack User manual Power Supply 18
8 MGE UPS Systems 12280 kVA User manual Power Supply 0
9 MGE UPS Systems 2000 User manual Power Supply 31
10 MGE UPS Systems 12 kVA User manual Power Supply 7
11 MGE UPS Systems 1500 Tower User manual Power Supply 16
12 MGE UPS Systems 1500C User manual Power Supply 35
13 MGE UPS Systems 18/280 kVA User manual Power Supply 4
14 MGE UPS Systems 2000 RT 2U User manual Power Supply 59
15 MGE UPS Systems 300 User manual Power Supply 82
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2