Device: MGE UPS Systems 1500C
Category: Power Supply
Manufacturer: MGE UPS Systems
Size: 0.87 MB
Added : 3/24/2013
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MGE UPS Systems 1500C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MGE UPS Systems 1500C.

For your convenience

If looking through the MGE UPS Systems 1500C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MGE UPS Systems 1500C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MGE UPS Systems 1500C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MGE UPS Systems 1500C User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MGE UPS Systems 1500C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MGE UPS Systems 1500C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.mgeups.com MGE UPS SYSTEMS
Pulsar
EXtreme CLA
1500C
Installation and user
manual
51031998EN/AA - Page 1

Summary of the content on the page No. 2

Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EXtreme range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar EXtreme a reference in environmental protection include: w the eco-design approach used in product developm

Summary of the content on the page No. 3

Safety Safety rules Safety of persons When the batteries are connected to the UPS, the outlets may be energised even if the UPS is disconnected from the AC input source. Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5 mA. Product safety UPSs must be connected to a nearby

Summary of the content on the page No. 4

Foreword Using this document Information may be found primarily by consulting: w the contents, w the index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Earth cables Other cables Page 4 - 51031998EN/AA

Summary of the content on the page No. 5

Contents 1. Presentation 1.1 Pulsar EXtreme range................................................................................................................. 7 Tower model.................................................................................................................................... 7 Rack model ..................................................................................................................................... 7 1.2 Back ................................

Summary of the content on the page No. 6

Contents 3.4 Personalisation (optional) ........................................................................................................... 22 Function ........................................................................................................................................ 22 "ON / OFF conditions" tab............................................................................................................. 22 "Battery" tab ................................................

Summary of the content on the page No. 7

1. Presentation 1.1 Pulsar EXtreme range Tower model Dimensions in mm Weight in kg (H x W x D) 235.5 x 145 x 505 9.5 Rack model Dimensions in mm Weight in kg (H x W x D) 88 (2U) x 482.6 x 493 12.5 51031998EN/AA - Page 7 EX1000 Rack

Summary of the content on the page No. 8

1. Presentation 1.2 Back Tower model 4 1 slot for communications-card option. 1 2 RS232 communications port. 2 3 3 USB communications port. USB RS232 9 4 four outlets for direct connection of protected equipment. 10 6 input circuit breaker. 7 socket for connection to AC-power source. 1 8 connector for battery connection. 8 2 9 pushbutton to test phase/neutral inversion of AC-power source. 11 6 10 LED indicating phase/neutral inversion of AC-power source. 7 11 two programmable outlets (outlet 1 a

Summary of the content on the page No. 9

1. Presentation Rack model 1 3 8 11 4 USB 2 1 RS232 2 9 10 6 7 8 slot for communications-card option. connector for battery connection. 1 2 RS232 communications port. pushbutton to test phase/neutral inversion of 9 AC-power source. 3 USB communications port. 10 LED indicating phase/neutral inversion of 4 four outlets for direct connection of AC-power source. protected equipment. 11 two programmable outlets (outlet 1 and 2). 6 input circuit breaker. 7 socket for connection to AC-power source. 51

Summary of the content on the page No. 10

1. Presentation 1.3 Control panel Alarms % battery ␣␣␣␣␣ % load remaining % 12 UPS overload. 100 % 100 % 100% 13 electronics fault. 80 % 80 % 80% 50% battery fault. 50 % 50 % 14 20% 15 20 % 20 % % 16 hold down to display percent load: - lamp test or buzzer OFF. test - forced transfer to bypass and back 17 by pressing button 3 times in less than 5 seconds. 1 18 status of programmable outlet 1: Supplied with power 2 19 status of programmable outlet 2: Status change in progress.

Summary of the content on the page No. 11

2. Installation 2.1 Unpacking and checks Tower model 24 26 25 29 27 28 30 two cords for connection of the protected equipment. 24 RS 232 communications cable. 25 USB communications cable. 26 "UPS Driver" diskette for UPS personalisation. 27 "Solution Pac" CD ROM. 28 documentation. 29 ␣ 30 box for battery connection. 51031998EN/AA - Page 11

Summary of the content on the page No. 12

2. Installation Rack model 24 24 25 26 31 27 28 29 30 ␣24 two cords for connection of the protected equipment. ␣25 RS 232 communications cable. ␣26 USB communications cable. ␣27 "UPS Driver" diskette for UPS personalisation. ␣28 "Solution Pac" CD ROM. ␣29 documentation. ␣30 box for battery connection. ␣31 telescopic rails for mounting in 19" bay with mounting hardware. Page 12 - 51031998EN/AA EX1000 Rack

Summary of the content on the page No. 13

2. Installation 2.2 Installation of the rack version Rack mounting diagram with rails. 1 3 3 3 4 3 2 The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. 51031998EN/AA - Page 13 EX1000 Rack

Summary of the content on the page No. 14

2. Installation 2.3 Connection to the RS 232 or USB communications port (optional) 1 - Connect the RS 232 25 or USB 26 communications cable to the serial port or the USB port on the computer. 25 2 - Connect the other end of the USB RS232 communications cable 25 or 26 to the RS 26 2 3 232 2 or USB 3 communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. USB 3 2 RS232 The RS 232 and USB communications ports cannot

Summary of the content on the page No. 15

2. Installation 2.4 Installation of the communications-card option Tower model 1 Slot for the communications-card It is not necessary to shut down the UPS to option. install the communications card: RS232 USB 1 - Remove the slot 1 cover secured by two screws. 2 - Insert the card in the slot. 3 - Secure the card with the two screws. 1 2 Rack model 1 Slot for the communications- card option. 2 1 USB RS232 51031998EN/AA - Page 15

Summary of the content on the page No. 16

2. Installation 2.5 Battery connection Warning The batteries should be connected only by qualified electrical installation specialists. The work involved in connecting the batteries must be carried out in accordance with all applicable rules and regulations, respecting all safety measures for working on live equipment, i.e. qualified personnel using insulated gloves, protective eyeware, insulated tools, etc. Interconnecting the batteries to obtain the required configuration Wire the batteries as

Summary of the content on the page No. 17

2. Installation Tower model 8 b a OFF c 40 A curve C d 6 m max. Cable and circuit-breaker not supplied e 140 g 10 10 f 10 10 j i h 51031998EN/AA - Page 17 40A 12V-65Ah 40A

Summary of the content on the page No. 18

2. Installation Rack model 1 8 2 1 2 b OFF c 40 A curve C a 6 m max. d Cable and circuit-breaker not provided e 140 g 10 10 f 10 10 j 1 2 1 2 i h Page 18 - 51031998EN/AA USB RS232 40A 12V-65Ah 40A

Summary of the content on the page No. 19

2. Installation 2.6 UPS connection and settings Tower model Connecting the UPS to the AC-input source 1 - Remove the power cord supplying the 4 equipment. Check cord characteristics (> 250 V, 10 A, see the technical sheet). 2 - Connect the cord to the AC-power socket ␣␣7 on the UPS, then to the AC-power wall outlet. Setting the UPS for the installed battery configuration 11 (For a 2-hour configuration, skip this step, this is the default setting for the UPS). 24 The UPS is set using the ÒUPS D

Summary of the content on the page No. 20

3. Operation 3.1 Start-up The protected equipment connected to the UPS can be energised, whether AC input power is available or not. Caution: the AC input power source must be present when energising for the first time. Press the ON / OFF button 23 . The buzzer beeps and all the LEDs go ON. The buzzer beeps twice, then: - If AC input power is available, LED 21 goes ON, indicating operation 21 in ON-LINE mode. - If AC input power is not available and the UPS is configured for 22 automatic rest


Alternative user manuals
# User manual Category Download
1 MGE UPS Systems 11+ User manual Power Supply 46
2 MGE UPS Systems 1100 Tower User manual Power Supply 21
3 MGE UPS Systems 1200 User manual Power Supply 27
4 MGE UPS Systems 1100 User manual Power Supply 64
5 MGE UPS Systems 1100 Rack User manual Power Supply 21
6 MGE UPS Systems 14+ User manual Power Supply 40
7 MGE UPS Systems 1500 Rack User manual Power Supply 18
8 MGE UPS Systems 12280 kVA User manual Power Supply 0
9 MGE UPS Systems 2000 User manual Power Supply 31
10 MGE UPS Systems 12 kVA User manual Power Supply 7
11 MGE UPS Systems 1500 Tower User manual Power Supply 16
12 MGE UPS Systems 18/280 kVA User manual Power Supply 4
13 MGE UPS Systems 2000 RT 2U User manual Power Supply 59
14 MGE UPS Systems 300 User manual Power Supply 82
15 MGE UPS Systems 3.5 to 21 kVA N+1 User manual Power Supply 4
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2