MGE UPS Systems 2000 user manual

User manual for the device MGE UPS Systems 2000

Device: MGE UPS Systems 2000
Category: Power Supply
Manufacturer: MGE UPS Systems
Size: 1.35 MB
Added : 3/24/2013
Number of pages: 34
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MGE UPS Systems 2000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MGE UPS Systems 2000.

For your convenience

If looking through the MGE UPS Systems 2000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MGE UPS Systems 2000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MGE UPS Systems 2000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MGE UPS Systems 2000 User manual - Online PDF
Advertisement
« Page 1 of 34 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MGE UPS Systems 2000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MGE UPS Systems 2000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.mgeups.com
MGE UPS SYSTEMS
Pulsar EXtreme
2000/3000 VA
Installation and user
manual
51033211EN/AC - Page 1
R
E
D
I
V
R O
P
R
E
W
O
P
E
L
B
I
T
P
U
R
E R
T
N
I
N
U
E
H
T

Summary of the content on the page No. 2

Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EXtreme range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar EXtreme a reference in environmental protection include: ◗ Production in an ISO 14001 certified factory, ◗

Summary of the content on the page No. 3

Foreword Using this document Information may be found primarily by consulting: ◗ The contents, ◗ The index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. 51033211EN/AC - Page 3

Summary of the content on the page No. 4

Contents 1. Presentation 1.1 Pulsar EXtreme range................................................................................................................. 7 Tower model.................................................................................................................................... 7 Rack model ..................................................................................................................................... 7 1.2 Connection modules ..................

Summary of the content on the page No. 5

Contents 3.4 Failure of AC input power and operation on battery power.................................................... 21 Transfer to battery power .............................................................................................................. 21 Threshold for the low-battery shutdown warning .......................................................................... 21 End of backup time ...........................................................................................

Summary of the content on the page No. 6

1. Presentation 1.1 Pulsar EXtreme range Tower model Dimensions in mm (H x W x D) EXtreme 2000 - 3000 443 x 173 x 465 Weight in kg Pulsar EXtreme 2000 29 Pulsar EXtreme 3000 36 Rack model Dimensions in mm (H x W x D) EXtreme 2000 - 3000 177 (4U) x 483 x 462 Weight in kg Pulsar EXtreme 2000 31 Pulsar EXtreme 3000 38 Page 6 - 51033211EN/AC

Summary of the content on the page No. 7

1. Presentation 1.2 Connection modules Fault tolerant 1 Socket for connection to AC-power source. 2 Outlets for direct connection to protected equipment. 3 Manual bypass switch. 1 4 Input terminal block with cable clamp. 2 5 Output terminal block with cable clamp. Hot swap Different types of sockets available on Fault tolerant and Hot swap connection modules: AC input cord Outlet sockets Power cords to 3 equipment USE DIN plug, 4 USE outlets (16A) 1 2.5m cable, IEC320C20 cable DIN 4 DIN outlets

Summary of the content on the page No. 8

1. Presentation 1.3 Back 6 Slot for communications-card option. 7 Battery module connector. 8 Battery circuit breaker. Rating plate. 9 Connector for connection modules. 10 11 RS232 communications port. Page 8 - 51033211EN/AC

Summary of the content on the page No. 9

1. Presentation 1.4 Options Transformer for galvanic isolation or earthing arrangement change Pulsar EXtreme Transformer Nominal power 3 kVA Nominal current 16 A Input voltage 230V (+15%, -20%) Voltage drop < 3% Frequency 50/60 Hz (+/-10%) Isolation (EN 61558-1-2-4) 3.75 kV / 5 M ohms Operating temperature From 0° to +40°C Max. operating rel. humidity 95% Pn-10% > 1000 m Derating / altitude Natural ventilation IP20 ANAN 443 x 173 x 465 mm Dimensions HxWxD (tower) Dimensions HxWxD (rack 4U) 177 x

Summary of the content on the page No. 10

1. Presentation CLA module (Long backup time charger) for backup times of 2 to 8 hours Very long backup times, from 2 to 8 hours at full load, require a Pulsar EXtreme CLA module (2000VA or 3000VA). Visit our Web site: www.mgeups.com/products/pdt230/smallups/extreme/cla/cla2.htm. Pulsar EXtreme Pulsar EXtreme CLA 6 6 6 9 9 9 2 2 2 1 1 2 1 2 2 1 1 1 2 h 4 h 8 h Page 10 - 51033211EN/AC 7 10 7 10 7 10 2000VA 3000VA 2000VA 3000VA 2000VA 3000VA 25A 12V-65Ah 12V-65Ah 12V-65Ah 12V-65Ah 12V-65Ah 12V-65

Summary of the content on the page No. 11

1. Presentation 1.5 Control panel Alarms % battery % load remaining 14 UPS overload 100% 100% 15 Electronics fault 80% 80% 16 Battery fault 50% 50% 17 Ambient temp. 20% 20% > 40°C 18 Hold down to display percent load. 19 Lamp test or buzzer OFF. 20 Operation on manual bypass. 21 Operation on automatic bypass. bypass Operation in ON-LINE mode. 22 23 Operation on battery power. 24 ON/OFF. 51033211EN/AC - Page 11

Summary of the content on the page No. 12

2. Installation 2.1 Unpacking and checks Tower model 29 27 26 25 28 25 RS 232 communications cable. 26 CD ROM with "Solution Pac" and "UPS Driver" softwares. Quick Start documentation. 27 28 Installation and user manual. Electrical power cord (except INST 29 ALL version and version with IEC outlets). Page 12 - 51033211EN/AC

Summary of the content on the page No. 13

2. Installation Rack model 30 29 27 25 26 28 25 RS 232 communications cable. CD ROM with 26 "Solution Pac" and "UPS Driver" softwares. 27 Quick Start documentation. Installation and user manual. 28 29 Electrical power cord (except INSTALL version and version with IEC outlets). 30 Telescopic rails for mounting in 19" bay with mounting hardware. 51033211EN/AC - Page 13

Summary of the content on the page No. 14

2. Installation 2.2 Installation of the rack version Rack mounting diagram with rails. 1 3 3 3 4 3 2 The rails and the necessary mounting hardware are supplied with the UPS in the package. Page 14 - 51033211EN/AC

Summary of the content on the page No. 15

2. Installation 2.3 Connection to the RS 232 communications port (optional) 25 1. Connect the RS 232 communications cable to the serial 11 port on the computer. 25 25 2. Connect the RS 232 communications cable to the RS 232 11 communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. Pin-out diagram for the RS 232 communications port 11 on the UPS. RD TD OV 5 4 3 2 1 9 8 7 6 RTS 2.4 Installat

Summary of the content on the page No. 16

2. Installation 2.5 Securing and connecting the connection modules Securing the connection modules 1. Insert the connection module in the connector . 10 2. Secure the connection module to the UPS using 10 the two screws . 31 31 31 Fault tolerant Before carrying out any connections, check that the battery circuit breaker is OFF and that the 8 electrical power cord to the AC-power source is disconnected. Connection of equipment: Connect the protected equipment directly to the outle

Summary of the content on the page No. 17

2. Installation Hot swap Before carrying out any connections, check that the battery circuit breaker is OFF 8 and that the electrical power cord to the AC-power source is disconnected. Connection of equipment to outlets 2 Plug your equipment into the outlets . Connection of equipment to a terminal block: This type of connection must be carried out by qualified electrical personnel. 2 32 1. Remove the terminal-block cover . 2. Insert the cable supplying the equipment through the ca

Summary of the content on the page No. 18

2. Installation Install This type of connection must be carried out by qualified electrical personnel. 8 Before carrying out any connections, check that the battery circuit breaker is OFF and that the upstream protection devices (AC distribution system) are open (OFF). The overall cable diameter and the cross-sectional area of the three wires depends on the UPS rating. 8 Pulsar EXtreme Pulsar EXtreme 2000 3000 From 9 to 12 mm From 9 to 12 mm Cable diameter 2 2 Cross-sectional area of each

Summary of the content on the page No. 19

3. Operation 3.1 ON-LINE operating mode This is the normal operating mode for the UPS. bypass Two possible cases: 22 LED is ON: 22 AC input power is available. Power is drawn from the distribution system and supplied to the protected equipment via the UPS. bypass 23 LED is ON: AC input power is not available. Power is drawn from the battery and supplied to the protected equipment. 23 51033211EN/AC - Page 19

Summary of the content on the page No. 20

3. Operation 3.2 Start-up Prior to initial start-up, check the UPS voltage settings. The frequency of the output voltage (50 or 60 Hz) is automatically set to that of the input source. 1. Close the upstream device (ON position) controlling the supply of AC power to the UPS. 2. Set the battery circuit breaker(s) to ON. 8 8 The buzzer beeps three times. If the supply frequency is different than the default value set on the UPS, the new value is set and the buzzer beeps 4 times. 3. Press the


Alternative user manuals
# User manual Category Download
1 MGE UPS Systems 11+ User manual Power Supply 46
2 MGE UPS Systems 1100 Tower User manual Power Supply 21
3 MGE UPS Systems 1200 User manual Power Supply 27
4 MGE UPS Systems 1100 User manual Power Supply 64
5 MGE UPS Systems 1100 Rack User manual Power Supply 21
6 MGE UPS Systems 14+ User manual Power Supply 40
7 MGE UPS Systems 1500 Rack User manual Power Supply 18
8 MGE UPS Systems 12280 kVA User manual Power Supply 0
9 MGE UPS Systems 12 kVA User manual Power Supply 7
10 MGE UPS Systems 1500 Tower User manual Power Supply 16
11 MGE UPS Systems 1500C User manual Power Supply 35
12 MGE UPS Systems 18/280 kVA User manual Power Supply 4
13 MGE UPS Systems 2000 RT 2U User manual Power Supply 59
14 MGE UPS Systems 300 User manual Power Supply 82
15 MGE UPS Systems 3.5 to 21 kVA N+1 User manual Power Supply 4
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2