Liebert UPStation S VM12000 user manual

User manual for the device Liebert UPStation S VM12000

Device: Liebert UPStation S VM12000
Category: Power Supply
Manufacturer: Liebert
Size: 1.23 MB
Added : 3/24/2013
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert UPStation S VM12000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert UPStation S VM12000.

For your convenience

If looking through the Liebert UPStation S VM12000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert UPStation S VM12000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert UPStation S VM12000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert UPStation S VM12000 User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert UPStation S VM12000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert UPStation S VM12000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
UPStation S
Power Protection
U ser M anual
English

Summary of the content on the page No. 2

CAUTION: This device complies with limits for a Class A computing device, pursuant to Part 15 of SAVE THESE IMPORTANT UPS AND BATTERY SAFETY INSTRUCTIONS FCC rules. Operating this device in a residential area is likely to cause harmful interference to CONSERVER CES INSTRUCTION. CETTE NOTICE radio and TV reception which the user must CONTIENT DES INSTRUCTIONS IMPORTANTES correct at his own expense. CONCERNANT LA SÉCURITÉ. ADVERTISSEMENT: laissées sans protection durant ces procedures WARNING:

Summary of the content on the page No. 3

• Porter toujours des vêtements protecteurs ainsi que • • immédiatement et généreusement avec de I’eau. Lorsque I’électrolyte est renversée, la surface affectée devrait être nettoyée en utilisant un agent neutralisant adéquat. Une pratique courante est d’utiliser un mélange d’approximativement une livre (500 grammes) de bicarbonate de soude dans approximativement un gallon (4 litres) d’eau. Le mélange de bicarbonate de soude réaction (mousse). Le liquide résiduel devra être nettoyé 3 a I’e

Summary of the content on the page No. 4

System Shutdown .............................................. 15 Manual Off ................................ ........................ .......................... INTRODUCTION .......................................6 UPS Alarms ........................................................ 15 ................................................................ 6 OPTIONS ................................................ 16 ............................... 6 ............................ 6 Distribution.........

Summary of the content on the page No. 5

Liebert UPStation S™ SITE PLANNING DATA 2170 2411 3616 4520 5062 7593 270 270 560 560 560 780 9x31x29 9x31x29 9x31x29 9x31x29 18x27x29 27x27x29 30 A 30 A 100 A 100 A 100 A 125 A 23 A 22 A 21 A 20 A 19 A 25 A 25 A 25 A 25 A 25 A 40 A 39 A 36 A 35 A 33 A 50 A 48 A 46 A 44 A 42 A 60 A 58 A 55 A 52 A 50 A 90 A 87 A 82 A 78 A 75 A 200/100 208/120 220/110, 220/127, 220 L-N 230/115 240.120, 240 L-N 200/100 208/120 220/110, 220/127, 220 L-N 230/115 240.120, 240 L-N 200/100 208/120 220/110, 220/127, 220

Summary of the content on the page No. 6

INTRODUCTION UNLOADING THE UPS The Liebert UPStation S™ Uninterruptible power supply (UPS) system protects valuable equipment, data, and 1. processes from utility power disturbances. The high- 2. performance, on-line, microprocessor-controlled design 3. ensures clean, regulated, sinewave power to loads 4. regardless of utility power fluctuations. An internal battery 5. 6. Remove front pallet hex bolts (F). Remove the front This highly intelligent UPS alerts you to unusual 7. circumstanc

Summary of the content on the page No. 7

3.5 - 6 kVA Liebert UPStation S™ systems include the INSTALLATION UPS and the AC unit. The unit provides connection to both utility power and UPS output power through the use Read Operation section to understand user controls and of a simple Maintenance Bypass Switch. See the Operation section for instructions on Maintenance Bypass Switch use. Operate UPS in a clean, controlled environment with Input Exposure to excessive dirt or dust adversely affects UPS The input power cord includes a NEMA

Summary of the content on the page No. 8

gap exists. Thread hex nuts back onto guide pins 3.5-6 kVA Start-up Checklist 8. Verify the Maintenance Bypass Switch (switch SW2 1. Remove POD from box. Set aside the two UPS battery fuses inside the user manual packet for later 9. Turn off all UPS-supported loads and plug them into 10. Install the two battery fuses (F3 and F4). The second Steps 2 – 4 apply to UPS Hardwire Input / Output fuse completes a circuit. The spark is a normal ONLY. 11. Roll unit to final position. Allow at least

Summary of the content on the page No. 9

Table #1 – Compression Field Connections 8-18 kVA Connections Connection Wire Size Torque (lb.in) Range (AWG) CAUTION: A qualified electrician must review and - 8 –12 kVA Liebert UPStation S™ approve the customer-supplied wiring, circuit AC Input breaker(s), power outlet, and intended loads. Ensure #14 - #2.0 #2.0 - #6 = 45 correct line, neutral, and ground connections, and that #8 = 40 phase rotation is phase A leads phase B (leads phase #10 - #14 = 35 C, if third phase is used). See Table #5

Summary of the content on the page No. 10

8 - 18 kVA Start-Up Checklist 1. 2. 8. The LCD display prompts you to review and accept default settings or configure the UPS for your 3. Turn OFF critical loads and plug them into output 9. After configuration, automatic self-tests begin. If self- 4. tests are OK, a horn sounds and the ”Close Breaker 5. Roll unit to final position. If using flexible conduit for then Press ON” message appears. If any other power connections, allow at least 18 inches of clearance around the UPS with enough co

Summary of the content on the page No. 11

OPERATION LCD Display Control / Display Panel NORMAL OPERATION a menu-driven LCD (liquid crystal display). The display provides full metering, present status, and alarms, if any. NOV 21 12:45 Press for Menu Control Buttons ON Button - This button turns on the UPS inverter. It supplies power to the output if the Output Circuit Breaker is closed. The ON button also restarts the UPS after a ESC OFF Button - Press this button twice to cause an orderly shutdown of the unit. The u

Summary of the content on the page No. 12

User Menus - UPS Meters • Configuration • UPS Meters • Event Log • Test Options • Power Management Configuration Configuration Setting Default Value Event Log option allows review of the Alarm History log and the Input Disturbances log. The Test Options option allows a Screen Test (Enter then ESC) and a 0 Hrs Battery Test (Enter begins a 30 second test) NOTE: See the following page for a complete menu tree. See the Options section for more information about Power Options) 1.0 1.0 Auto-R

Summary of the content on the page No. 13

LCD MENU TREE MAIN MENU Power Event Test UPS Configuration Management Log Options Meters % N W Y E S s Change Review I s Settings s G E 1 E T Y Y E E S Y z g e e t e e E S g L1-L2-N-G L1-N-G L1-L2-L3-N-G g L1-L2-N-G L1-L2-G L1-N-G e English French e t e e Manual f s Review 13 Program Custom Relays Battery Installation Date Transfer UPS to Bypas UPS on/of Set Password Auto Start-up Mode

Summary of the content on the page No. 14

System Start-Up In addition, the charger has two recharge rates, user- selectable through the LCD display. The ”turbo” rate Manual Restart after Manual Off recharges batteries to 95% capacity within 10 times the If Manual Restart has been selected (rather than Auto- discharge duration. The ”standard” rate recharges Restart) and someone has turned the unit off, the Output batteries to 95% capacity within 20 times the discharge duration. Select the ”standard” factory default setting rate With ”

Summary of the content on the page No. 15

Maintenance Bypass Operation System Shutdown Manual Off Pressing the OFF button twice removes power to the load The POD includes a Maintenance Bypass Switch that by turning off the inverter and opening the bypass. The allows UPS removal for service or maintenance without Output Circuit Breaker remains closed, even though Pressing the OFF button twice disables Auto-Restart until Transferring from UPS Operation to Maintenance you press the ON button, but control logic and battery Bypass Operation

Summary of the content on the page No. 16

OPTIONS Distribution Configurable Distribution (CD) d BACK VIEW ) TB2 L1 L2 N SIDE “ TB1 N L1 L2 l Customer g Output l G Rack may be mounted 4“ to the right or left of location shown. 16“(REF) Power Management Rack Mat’l r c t P 0 t VIEW A Output l Blocks Output Breaker NOTES • W eight, including load modules, about 100 lbs. per connection • Attach brackets to wall as shown using customer- supplied 1/4” hex head lag screw or equivalent hardware. a • Options: 5’ UPS to CD Power Cable, 5’ Power Ma

Summary of the content on the page No. 17

Standard Load Module Load Modules Load Modules for 3.5 to 12 kVA units offer a variety of power receptacles when used in conjunction with the 1. 2. 3. Hardwire Load Module Hard Wire (terminal block) Load Modules provide a Remove screw to open module knockout to attach flexible conduit (see drawings to the cover for terminal block access. right). Use no more than three feet of conduit to avoid attachment points required by national and local codes. Terminal compression lugs accept wire size 4

Summary of the content on the page No. 18

Standard Features Maintenance Bypass 8 - 18kVA • A locking handle prevents unauthorized The Liebert UPStation S™ Maintenance Bypass the UPS for repair and/or preventive maintenance. A rotary switch provides a make- • A holder for the User’s Manual and any site before-break system that enables a transfer to documentation is provided on the inside and from maintenance bypass without cover of the door. This enables the customer to keep all documentation relating to their UPS and maintenance bypas

Summary of the content on the page No. 19

Test When the rotary switch is placed in the Test position, contacts A and B are closed and C is open. The power for the load is now coming from the maintenance bypass source, as illustrated in below. The connection from the output of the UPS is open. Input power to the UPS is still available for testing and MAINTENANCE BYPASS UTILITY CRITICAL FEED LOAD B A C BYPASS PFC INVERTER BYPASS BATTERIES UPStation S™ Maintenance When the rotary switch is placed in the Maintenance position, contacts A

Summary of the content on the page No. 20

INSTALLATION This section includes unloading, inspection, mounting and connections for the maintenance bypass UNLOADING complete a freight damage claim form. Insure that the system ordered is what was to a pallet. To unload the maintenance bypass Mounting • The Liebert UPStation S™ Maintenance Bypass Prior to installation, verify that the wall can support • the weight of the bypass cabinet. Weights can be found on page 18. • Inspect for any damage to the unit. Report any damage to the shippi


Alternative user manuals
# User manual Category Download
1 Liebert 130 kVA User manual Power Supply 19
2 Liebert 208V User manual Power Supply 13
3 Liebert 1500 User manual Power Supply 27
4 Liebert 30-130kVA User manual Power Supply 8
5 Liebert 115V User manual Power Supply 8
6 Liebert 230V User manual Power Supply 13
7 Liebert 2U User manual Power Supply 11
8 Liebert 2700VA User manual Power Supply 6
9 Liebert 500-650 VA User manual Power Supply 4
10 Liebert 4000 User manual Power Supply 4
11 Liebert 50 and 60 Hz User manual Power Supply 1
12 Liebert 350-700 VA User manual Power Supply 2
13 Liebert 6000 A User manual Power Supply 7
14 Liebert 600TTM User manual Power Supply 2
15 Liebert 700-2200 VA User manual Power Supply 13
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2